Product features
|
Parameters
|
|
Testeable hardness system
|
See Table 1 for details
|
|
test accuracy
|
See Table 2 for details
|
|
Standard impact device
|
D-type impact device
|
|
Setting the measurement range for upper and lower limits
|
none
|
|
Optional impact device
|
none
|
|
Number of impact devices that can be equipped at the same time
|
Integrated machine with D-type impact device
|
|
computer interface
|
none
|
|
text description
|
Display in Chinese/English
|
|
screen display
|
none
|
|
Testing direction
|
arbitrary
|
|
data storage
|
Store 1 set of values (current test value)
|
|
Measure the large hardness fluctuation value of the workpiece
|
940HV (D impact device)
|
|
Measure the curvature radius of the workpiece
|
Rmin=50mm (using a special-shaped support ring Rmin=10mm)
|
|
Automatic recognition of impact device type function
|
none
|
|
Printer type
|
none
|
|
Quantity of testing materials
|
See Appendix Table 1 for 10 details;
|
|
Automatic voltage detection
|
have
|
|
power supply
|
lithium battery
|
|
charger
|
have
|
|
Overall dimensions
|
145×35×30m
|
|
weight
|
About 130g
|
| material |
| Hardness system | Impact device | |
| D | ||
| Steel and cast steel | HRC | 17.9~68.5 |
| Steel and cast steel | HRB | 59.6~99.6 |
| HRA | 59.1~85.8 | |
| HB | 127~651 | |
| HV | 83~976 | |
| HS | 32.2~99.5 | |
| Steel forged steel | HS | 32.2~99.5 |
| CWT、ST | HRC | 20.4~67.1 |
| Alloy tool steel | HV | 80~898 |
| Stainless steel | HRB | 46.5~101.7 |
| stainless steel | HB | 85~655 |
| HV | 85~802 | |
| GC. IRON | HRC | |
| gray cast iron | HB | 93~334 |
| HV | ||
| NC、IRON | HRC | |
| ductile cast iron | HB | 131~387 |
| HV | ||
| C.ALUM | HB | 19~164 |
| cast aluminum alloy | HRB | 23.8~84.6 |
| BRASS | HB | 40~173 |
| copper-zinc alloy | HRB | 13.5~95.3 |
| BRONZE Copper Tin (Aluminum) Alloy | HB | 60~290 |
| COPPER Pure Copper | HB |
| 45~315 |
|
serial number
|
Type of impact device
|
Standard Leeb hardness block hardness value
|
indication error
|
indication repeatability
|
|
1
|
D
|
760±30HLD
530±40HLD |
±6 HLD
±10 HLD |
6 HLD
10 HLD |
|
2
|
DC
|
760±30HLDC
530±40HLDC |
±6 HLDC
±10 HLDC |
6 HLD
10 HLD |
|
3
|
DL
|
878±30HLDL
736±40HLDL |
±12 HLDL
|
12 HLDL
|
|
4
|
D+15
|
766±30HLD+15
544±40HLD+15 |
±12 HLD+15
|
12 HLD+15
|
|
5
|
G
|
590±40HLG
500±40HLG |
±12 HLG
|
12 HLG
|
|
6
|
E
|
725±30HLE
508±40HLE |
±12 HLE
|
12 HLE
|
|
7
|
C
|
822±30HLC
590±40HLC |
±12 HLC
|
12 HLC
|