30BS-2002Stainless steel fermentation tankIndicators and configurations:
Tank system: Made of imported SUS316L stainless steel, with * inside the tank; Adopting a large angle liquid level observation mirror inside the tank, a 12V safety sight light is resistant to acid and alkali corrosion, and the inner and outer surfaces are treated with polished mirror surfaces, with a polishing accuracy of Ra0.4; Reduce the chance of bacterial infection and make it easy to clean; Liquid filling coefficient of 70%, process structure, simple operation.
Mixing system: using direct coupling mechanical mixing, adopting tank top mechanical seal system, British mechanical seal (John Crane), high-performance mixing blade, defoaming blade, AC speed regulating motor, stepless speed regulation, high-power variable speed mechanism ensures stable mixing and smooth operation without the need for lubricating oil, fully automatic setting control range of 50
RPM~rated speed ± 1%.
Ventilation control: manual control, flow meter display. Including rotor flowmeter, imported filter membrane air sterilization filter, with a filtration accuracy of up to 0.02 μ m
Temperature control: jacketed water bath electric heating, automatic control, temperature control cooling water temperature 5 ℃~65 ℃± 0.2 ℃
Ventilation control: manual control, flow meter display
Foam control: full automatic PID control and alarm, peristaltic pump automatically adds defoamer
Feeding control: PID fully automatic setting peristaltic pump switch control, automatic flow addition and metering.
PH control: Swiss Mettler electrodes (compatible with high-quality domestic electrodes) are used, and the peristaltic pump automatically adds acid and alkali to accurately control pH. The display range is 0.00~14.00 ± 0.01, and the fully automatic control range is 2.00~12.00 ± 0.05.
DO control: using Swiss Mettler electrodes (or optional high-quality domestic electrodes), associated with speed (optional air flow, feeding, etc.) for control, 0-150 ± 3%, display accuracy of 0.1%.
Pressure control: manual control, instrument display
Control system: Single tank can use BIOTECH-2002 biological process controller supplemented with BIOTECH-FCS fermentation monitoring software, which allows you to observe fermentation changes on-site and remotely monitor the fermentation process; If multiple or multi-stage fermentation tanks are used, BIOTECH-3000/6000/8000/9000 biological process controllers can be used to achieve more measurement and control functions.
30BS-2002Stainless steel fermentation tankScalable features:
Automatic detection and control of air flow rate, tank pressure, and liquid level
Exhaust O2 and CO2 detection
Two additional feeding routes can be added