Small animals can automatically analyze electrocardiograms of animals such as mice, dogs, rabbits, cats, and monkeys; $r $n can receive electrocardiograms from physiological recorders, *, data recorders, and multiple output channels

Product Details

1Small animals*Details introduction:

It can automatically analyze electrocardiograms of animals such as mice, dogs, rabbits, cats, and monkeys;

Can receive electrocardiograms from physiological recorders, *, data recorders, and multiple output channels;

You can use an editor to enlarge the recorded waveform and re analyze it;

Can continuously record all heartbeats without interruption;

Real time analysis of electrocardiogram and accurate analysis of 24-hour electrocardiogram within 30 minutes;Different animal species correspond to different analytical modules and theoretical foundations;

Real time observation and analysis of results, monitoring and analyzing simultaneously;

Can be used for pre pharmaceutical review experiments and final toxicity and safety evaluation experiments;

It can print data results for easy storage and declaration.

IISmall animals*configuration

host:

Equipped with eight channels (RM-6280):

1. Sampling rateThe above is the sampling rate continuously recorded to the disk in real-time display state, and the sampling rate varies from1000kHz1HzAdjustable.

2. Scanning speed:0.2 ms /div3200 s /divAdjustable.

3. Amplifier input impedance ≥100MOh.

Common mode rejection ratio ≥100dB.

Noise ≤±3uv (100Hz).

frequency responseDC10 kHz

4. Time constant(High pass filtering):0.001sThe0.002sThe0.02sThe0.2sThe1sThe5sTheDC.

5. Low pass filtering:0.3HZThe3HZThe10HzThe30HzThe100HzThe500HzThe1kHzThe3kHzTheOFF.

6. Software filtering:Low energy, high pass, bandpass, bandstop

n1. Voltage sensitivity:

n Communication file:20μV、50μV、100μV、 200μV.500μV、1mV、 2mV、5 mV。

nDC and AC low gain modes:1mV、 2.5mV、5mV、10mV、25mV、50mV、100mV、250 mV。

through the Way number8通道

provide power supplyACPower supply(220V/1A

Communication method:USB

divide distinguish rate12 bit

2Pre amplifier:

2Pre amplifier:

Built in amplifier

Magnification factor: 10000 times

Applicable heart rate: 300-1000BPM

3Correction pulse outputStandard output 1mV, clamp type connection (1m connecting wire)

4. System software:

Components: Experimental information setting, ECG monitoring, ECG re elevation, ECG editing, with printing function.

Experimental information setting:

Animals and their corresponding parsing methods can be set. The objects set include: mice, rabbits, dogs, cats, monkeys, cows, horses, etc.

The analysis methods of electrocardiogram include:QTc, BAZETT, Frederica, Vander Water, atunaga, Oguchi。

Equipped with electromyographic interference filtering, power frequency filtering, etc. to make the electrocardiogram clearer.

You can input one or two lead electrocardiogram signals to the PC by connecting a physiological monitor or a Softron standard configuration amplifier. This system is capable of real-time parsing of electrocardiogram signals, recording parsing values of Pa, P, Q, R, S, R ', S', ST, T, T', Pd, QRS, RR, PR, Qt.

Electrocardiogram regeneration:

The recorded electrocardiogram can be regenerated and reanalyzed.

Electrocardiogram editing:

Fixed interval small files generated during electrocardiogram monitoring can be edited for clearer and more accurate analysis of electrocardiograms. It can generate 3 or 6 leads from 2 leads. Accurately locate measurement points such as P, Q, T, etc.

Printing function:

12Full mode printing of lead electrocardiogram

5. It has the function of expanding into a wireless telemetry system for physiological signals of mice and rats.