-
E-mail
15000157197@163.com
-
Phone
15000157197
-
Address
Room 803-804, Building B, Greenland East Coast Business Building, No. 5558 Chuansha Road, Pudong, Shanghai
Shanghai Xiangqian Instrument Co., Ltd
15000157197@163.com
15000157197
Room 803-804, Building B, Greenland East Coast Business Building, No. 5558 Chuansha Road, Pudong, Shanghai
I am pleased to introduce this new analyzer to our customers7MB2337-0NB00-3PT1 low range, better accuracy,More user-friendly and reassuring. Now let me introduce in detail to our customers which updates of our new model are more advanced
Model:7MB2337-0NB00-3PT1
NameULTRAMAT 23 Infrared Online Gas Analyzer
Measurement of gas and range:SO2:0-200-1000 MG/M3,NO:0-150-750 MG/M3,O2:0-25%
Suitable for industries such as power plants, steel mills, and petroleum,
Siemens' newly launched low range U23 analyzer has better accuracy,
GASANALYSEGERAET ULTRAMAT 23
FOR MEASURING 2 INFRA-
COMPONENTS AND OXYGEN
19 CUSTOM INDUSTRY FOR CONSTRUCTION
IN SCRAENKE, GAS CLOSURE 6MM
ROHR, WITHOUT INTERNAL MESSAGE PUMP
WITHOUT GAS TRAIN(2CHANNELS)
1.MESSKOMPONENTE: SO2
MINIMUM SCOPE:
0 BIS 200 MG/M3
MAXIMUM SCOPE:
0 BIS 1000 MG/M3
INFORMATION: WEEKENDS
Technical data
Without electricity. O2 Sensor
WITHOUT H2S SENSOR
HELP ENERGY: AC 230 V, 50 HZ
2.MESSCOMPONENTS: NO
2.MESSCOMPONENTS
MINIMUM SCOPE:
0 BIS 100 MG/M3
MAXIMUM SCOPE:
0 BIS 750 MG/M3
SERVICE SOFTWARE, DOCUMENTATION
ENGLISCH
The above are the technical parameters of this model. Our company has stock available, and if you need any consultation, we can provide you with high-quality service.
Due to increasingly strict environmental requirements and lower range accuracy requirements, in order to meet the needs of customers, Siemens launched a new ULTRAMAT 23 paramagnetic oxygen analyzer in 2014, both of which were newly released in this fiscal year. The measurement method for other gases is electrochemical, while oxygen is paramagnetic oxygen. When measuring several gases simultaneously, paramagnetic oxygen can also be achieved,
7MB2337-0NB00-3PT1 carbon oxide analyzer,
——What should I do if I can't find the discontinued spare parts?
——Looking for Shanghai Xiangrun, specializing in discontinued spare parts, *, *.
——The goods are very urgent and we need them soon. What if there is no place to receive them?
——Find Shanghai Xiangrun, there is a massive inventory, only what you can't think of, there is nothing we cannot do.
——Is the quality of your product guaranteed?
——Don't worry, don't worry, *, there's also a warranty, what are you afraid of
Basic characteristics
application
ULTRAMAT 23 gas analyzerCan measure four gas components at once: the most
Can measure three types of infrared sensitive gases, such as CO, CO2, NO, SO2, CH4, and
Measure O2 using an electrochemical oxygen measurement unit.
ULTRAMAT 23Basic types can be:
• Measurement of oxygen content in an infrared gas composition with (or without) band
• Measurement of oxygen content in two infrared gas components with (or without) bands
• Measurement of oxygen content in three infrared gas components with (or without) bands
For biogas applications, continuous measurement of four components. Measure two types of infrared gas components
Electrochemical measurement of oxygen or hydrogen sulfide with CO2 and CH4
Continuous measurement of four components with paramagnetic oxygen application. Measure three infrared gas components
Oxygen measurement using paramagnetic oxygen principle (not applicable for emission monitoring)
• Automatic calibration using ambient air: oxygen content calibration and zero point calibration of infrared components
It depends on the tested component
Multi layer detection ensures high accuracy and eliminates infrared cross interference
The sampling unit is easy to clean, reducing maintenance costs
• Menu assisted operation with simple text format, simple and easy to understand
• Maintenance information and record manual, preventive maintenance, can assist maintenance and upkeep personnel,
reduce costs
Open interface structure (RS 485, RS 232, PROFIBUS, SIPROM GA); Easy
Integration and Remote Control
Characteristics in the application of biogas
Continuous measurement of four components, including hydrogen sulfide
A long-lasting hydrogen sulfide sensor that is not affected by an increase in hydrogen sulfide concentration and does not require
Dilution and Backblowing
• Suitable for combustible gas applications
Application field
Optimization of Operation for Small Combustion Systems
Monitor combustion systems using all types of fuels (oil, gas, and coal)
Their exhaust emission concentration; It can also monitor the operation and detection of thermal incineration plants
• Monitor indoor air quality
Monitor the air conditions in fruit storage rooms, greenhouses, cellars, and warehouses
• Monitor the process and control various functions
Monitor environmental conditions during the heat treatment process of steel
• Used in environments without potential explosion hazards
Biogas field
• Monitor biogas fermentation production
• Monitor gas pressurization
• Monitor biological feed
Application field of paramagnetic oxygen
• Inert gas device
• Monitor indoor air quality
• Pharmaceutical Engineering
More applications
• Environmental protection
Chemical factory
• Cement industry
special application
Equipped with two IR components and without a pumpULTRAMAT 23 gas analyzer
Can be equipped with two independent air circuits. In this way, it can measure two sampling points simultaneously,
This measurement method can be used to measure, for example: before and after the conversion of NOx converter
NOx content.
ULTRAMAT 23 gas analyzer can be applied to flue gas emission monitoring systems and
Process and safety monitoring.
Certified by T Ü VULTRAMAT 23 gas analyzerCan be done according to 13
The requirements for measuring CO, NO, SO2, and O2 in BlmSCHV and TA Luft
The maximum allowable range certified by T Ü V:
Single component and two-component analyzers
- CO: 0 ~ 150 mg/m 3
- NO: 0 ~ 250 mg/m 3
- SO
2: 0 ~ 200 mg/m 3
Three component analyzer
- CO: 0 ~ 250 mg/m 3
- NO: 0 ~ 400 mg/m 3
- SO
2: 0 ~ 200 mg/m 3
All ranges larger than the above are also allowed.
design
The 19 '' rack unit comes with 4 HU (standard height) that can be installed on
-In the rotating structure
-In frames with or without sliding rails
Front panel sample gas flow meter;
Optional: Integrated sample air pump (standard configuration for portable models)
For the gas path connections of sample gas input and output, as well as calibration gas, the pipe diameter
6mm or 1/4 '
Gas and electrical connections are located at the rear (portable: sample gas inlet at the front end)
Display and Control Panel
According to the operation of NAMUR *
• The analyzer can be programmed and debugged simply and quickly
LCD display measurement values with large screen backlight
• Implement programming input, functional testing, and calibration through menu operations
• Washable membrane keyboard
• User assistance displayed in plain text format
• Operating software with 5 language displays
Overview
Input and output
• Used for starting/stopping the sample air pump, triggering automatic calibration, and synchronizing several devices
Three binary inputs
• Used for troubleshooting, maintenance requests, maintenance switching, setting limits, range recognition, and
The eight relay outputs of the external solenoid valve can be freely configured
Eight additional relay outputs (optional)
Eight additional binary inputs (optional)
Analog output of electrical isolation
communication
RS 485 is the basic configuration (connected from the back)
option
RS 232 converter TCP/IP Ethernet converter
• Connect to the network through the PROFIBUS-DP/PA interface
SIPROM GA software
7MB2338-0AA10-3NH1
7MB2335-1AR00-3AA1
7MB2335-0NG00-3AA1
7MB2335-0PV10-3AA1
7MB2337-0NH10-3PG1
7MB2337-0NH10-3PH1
7MB2337-0NH00-3PH1
7MB2338-0AK10-3NW1
7MB2335-1AM00-3AA1
7MB2337-0NG10-3PH1
7MB2337-1AH00-3CP1
7MB2337-0NW10-3PU1
7MB2337-0NW00-3PE1
7MB2337-8AG00-3CP1
7MB2337-0NJ10-3PJ1
7MB2337-0AE00-3AK1
7MB2337-0AE10-3AK1
7MB2337-8AE00-3AK1
7MB2337-8AK10-3AK1
7MB2337-8AE00-3DL1
7MB2337-8AE10-3DL1
7MB2337-0AE00-3DL1
7MB2337-0AE10-3DL1
7MB2338-0AK10-3NU1
7MB2335-0CE00-3AA1
7MB2337-0AM00-3CM1
7MB2335-0AR10-3AA0
7MB2335-1NH10-3AA1
7MB6122-0WG00-0XX1
7MB2335-2AQ00-3AA1
7MB2335-0AD00-3AA1
7MB2337-2AQ00-3CM1
7MB2338-1AA10-3NH1
7MB2335-0AJ00-3AA1
7MB2335-0NG10-3AA1
7MB2337-0NW10-3PE1
7MB2338-0AK00-3NW1
7MB2338-0AB00-3NH1
7MB2335-1NH00-3AA1
7MB2335-1MH00-3AA1
7MB2335-1AH00-3AA1
7MB2337-2AP00-3CP1
7MB2337-0NJ00-3PH1
7MB2335-0PG10-3AA1
7MB2337-0NG10-3PG1