The battery powered electromagnetic flowmeter is designed specifically for the water industry to ensure accurate water fee calculation for urban water supply. It is widely used in on-site areas without power supply, such as urban water supply, sewage treatment, water conservancy engineering, water administration, and water resources industries.
Characteristics of battery powered electromagnetic flowmeter:
Selection Table for Battery Powered Electromagnetic Flowmeters:


Specification and parameter table of battery powered electromagnetic flowmeter:
| Nominal diameter (mm) (Special specifications can be customized) |
Pipeline type: DN10 to DN3000 | |
| Insertion type: DN200~DN3000 | ||
| Flow direction: | Positive, negative, net traffic | |
| Range ratio: | 150:1 | |
| Repetitive error: | ± 0.1% of the measured value | |
| Accuracy level: | Pipeline type: 0.5 level, 1.0 level | |
| Temperature of the tested medium: | Ordinary rubber lining: -20 to+60 ℃ | |
| High temperature rubber lining: -20 to+90 ℃ | ||
| PTFE lining: -30 to+100 ℃ | ||
| High temperature PTFE lining: -20 to+180 ℃ | ||
| Rated working pressure: (High voltage can be customized) |
DN6-DN80:≤1.6MPa | |
| DN100-DN250:≤1.0MPa | ||
| DN300-DN1200:≤0.6MPa | ||
| Flow rate range: | 0.1-15m/s | |
| Conductivity range: | The conductivity of the measured fluid is ≥ 5 μ s/cm | |
| Current output: | load resistance | 0~10mA:0~1.5kΩ |
| 4~20mA:0~750 kΩ | ||
| Digital frequency output: | The upper limit of the output frequency can be set within 1-5000Hz with a transistor collector open circuit bidirectional output with photoelectric isolation. When the external power supply is ≤ 35V and conducting, the maximum current at the collector is 250mA | |
| Power supply: | AC220V, DC24V or 3.6V batteries | |
| Require the length of the straight pipe section | Upstream ≥ 5DN, downstream ≥ 2DN | |
| Connection method: | The flowmeter and piping are connected by flanges, and the flange connection size should comply with the provisions of GB11988 | |
| Explosion proof grade: | mdIIBT4 | |
| Protection level: | IP65, Specially customized up to IP68 | |
| Environmental temperature: | -25~+60℃ | |
| Relative temperature: | 5%~95% | |
| Total power consumption: | Less than 20W | |
Battery powered electromagnetic flowmeter caliber flow comparison table:
| Nominal diameter (mm) | Measurable flow range (m3/h) | Effective measurement flow range (m3/h) | Nominal diameter (mm) | Measurable flow range (m3/h) | Effective measurement flow range (m3/h) |
| 4 | 0.0135~0.4522 | 0.0135~0.4522 | 250 | 8.8313~2119 | 52.9875~1766 |
| 6 | 0.0305~1.0173 | 0.0305~1.0173 | 300 | 12.717~3052 | 76.302~2543 |
| 8 | 0.0543~1.8086 | 0.0543~1.8086 | 350 | 17.31~4154 | 103.86~3461 |
| 10 | 0.0142~3.3912 | 0.0848~2.826 | 400 | 22.61~5425 | 135.65~4521 |
| 15 | 0.0318~7.6302 | 0.1908~6.3585 | 450 | 28.62~6867 | 171.68~5722 |
| 20 | 0.0566~13.5648 | 0.3392~11.304 | 500 | 35.33~8478 | 211.95~7065 |
| 25 | 0.0883~21.195 | 0.5298~17.6625 | 600 | 50.87~12208 | 305.2~10173 |
| 32 | 0.1447~34.7258 | 0.8682~29.9382 | 700 | 69.24~16616 | 415.4~13847 |
| 40 | 0.2261~54.2592 | 1.3565~45.216 | 800 | 90.44~21703 | 542.6~18086 |
| 50 | 0.3533~84.78 | 2.1195~70.65 | 900 | 114.46~27468 | 686.7~22890 |
| 65 | 0.5970~143.28 | 3.5819~119.39 | 1000 | 141.3~33912 | 847.8~28260 |
| 80 | 0.9044~217.03 | 5.4259~180.86 | 1200 | 203.5~48833 | 1221~40694 |
| 100 | 1.413 ~339.12 | 8.478~282.6 | 1400 | 277~66467 | 1662~55389 |
| 125 | 2.2079~529.87 | 13.2468~441.56 | 1600 | 361.8~86814 | 2171~72345 |
| 150 | 3.1793~763 | 19.0755~635.85 | 1800 | 457.9~109874 | 2747~91562 |
| 200 | 5.652~1356 | 33.912~1130.4 |
Common problems with battery powered electromagnetic flow meters:
How long can a battery powered electromagnetic flowmeter last