RGYQ-3 hydrogen chloride samplingrod
RGYQ-3 hydrogen chloride samplingrod
Product OverviewSampling gun for smoke and gas from fixed sources of hydrogen chloride pollution
RGYQ-3 hydrogen chloride samplingrodMainly used for the collection of hydrogen chloride from fixed pollution source emissions. the samplingrodAdopting full heating method to ensure smooth passage of flue gasrodBody. Among them, particulate chloride is collected using a filter membrane, while gaseous hydrogen chloride and chlorine gas are collected using reagent bottles. Sampling can also measure parameters such as flue gas flow rate and temperature. It can be widely applied in various fields.
Execution standardsSampling gun for smoke and gas from fixed sources of hydrogen chloride pollution
HJ/T47-1999 Technical Conditions for Smoke Samplers
HJ/549-2016 "Determination of Hydrogen Chloride in Environmental Air and Waste Gas - Ion Chromatography Method"
GB16157-1996 "Determination of particulate matter and sampling methods for gaseous pollutants in exhaust from fixed sources of pollution"
Features
Adopting constant temperature heating to prevent adsorption of chloride samples.
samplingrodAdopting full heating and temperature control throughout the process(120 ± 5) ℃, digital temperature display, adjustable.
At the same time as sampling, smoke flow rate and smoke temperature can be measured.
samplingrodThe length can be customized according to customer needs.
samplingrodFilter using polytetrafluoroethylene membrane filter.
The membrane filter is controlled by a one-way valve.
Particulate chloride is collected using a filter membrane, while gaseous hydrogen chloride and chlorine gas are collected using an impact absorption bottle.
Equipped with a three legged bracket that can adjust the height, used to support samplingrodAnd absorption bottles.
Equipped with an absorption bottle refrigerator that can hold a mixture of ice and water.
Lined with PTFE tubing, the sampling gas path is made of PTFE material.
technical indicators
technical indicators
Main parameters |
parameter range |
Main parameters |
parameter range |
|
|
|
|
samplingrodlength |
1.0 meter |
samplingrodheating temperature |
(120±5)℃ |
|
|
|
|
Pitot tube coefficient |
0.84 |
Smoke temperature sensor (Pt100) temperature |
(0~500)℃ |
|
|
|
|
Requirements for measuring hole diameter |
≥φ45mm |
Impact absorption bottle |
75mL |
|
|
|
|
working power supply |
DC24V |
working power |
70W |
|
|
|
|
material |
tetrafluoroethylene tube |
Filter membrane diameter |
47mm |
|
|
|
|