SF-TOPI high-precision Leeb hardness tester
manyFunction - Beautiful appearance, color screen display, long standby time, dual hardness display, random printing ...
Product Introduction
The SF-TOPI high-precision Leeb hardness tester is designed based on the Leeb hardness principle, and the standard configuration uses a D-type high-precision impact device, which can perform high-precision testing on various metal materials; Design basis standard: Technical Conditions for Leeb Hardness Tester JB/T 9378-2001. Compliant with international standards and the "Technical Conditions for Leeb Hardness Tester ZBN7l 010-90" issued by the Ministry of Machinery Industry, the "Metallic Leeb Hardness Test Method GB/T 17394-199" issued by the Quality and Technical Supervision Bureau, and the Leeb Hardness Tester Standard JB/T9378-2001, American ASTM A956 and other standards.
Measuring materials: Steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile iron, cast aluminum alloy, copper zinc alloy (brass), copper tin alloy (bronze), pure copperforged steelAnd hardness measurement of custom materials.
Unique features:
Compatible with domestic market/Foreign conversion table, dual system operation between Chinese and English, more accurate Brinell measurement.
Main purpose:
The machining industry is particularly suitable for on-site hardness testing of large components and non removable parts
● Hardness of installed mechanical or sexual assembly components
● Mold cavity hardness
● Hardness of heavy-duty workpieces
Failure analysis of pressure vessels, steam turbine generators and their equipment
Workpiece hardness with a very small experimental space
● Hardness of bearings and other components
Material differentiation in metal material warehouses
Rapid inspection of multiple measurement points on a large scale of large workpieces

Features
LCD screen dual display:Can simultaneously display the corresponding hardness values of Leeb and other standards;
Plug and play probe:Can manually set and automatically recognize the impact device function, convenient for use in special situations (such as 2-wire probes);
Built in large capacity lithium-ion rechargeable batteryAnd charging control circuit;Can work continuously for no less than 150 hours; It has energy-saving functions such as automatic sleep mode and automatic shutdown; Leeb and other hardness can be displayed simultaneously
Convenient switching of all hardness standards (HL, HB, HRB, HRC, HRA, HV, HS), parallel conversion of various hardness measurement values;
large screen(320×240)、true colorTFT LCD display screen, with vivid and rich content, clear and intuitive information;
WOINDOWS interface styleFull Chinese display, user-friendly menu style operation, simple and convenient; The LCD brightness can be adjusted freely, making it convenient to use in dimly lit environments; WINDOWS interface operation is more intuitive
Add "Steel" materialWhen using a D/DC impact device to test "forged steel" specimens, the HB value can be directly read without the need for manual table lookup.
A host can be equipped with D, DL, G, C, DC, E, D+15 impact devices, which can automatically identify the type of impact device in real-time. No need to recalibrate when replacing;
Large capacity data storage:Can store large600 sets(Impact frequency 32-1) Hardness measurement data, including single measurement value, average value, measurement date, impact direction, frequency, material, hardness system and other information;
Pre set upper and lower limits, as well as over limit alarms, to facilitate batch testing by users;
Streamlined shellCompact, portable, highly reliable, suitable for harsh operating environments, resistant to vibration, impact, and electromagnetic interference;
Reasonable support structure design, convenient for on-site operation and printing;
The integrated design of the host and thermal printer ensures quiet operation, fast printing speed, and on-site printing of inspection reports;
Remaining battery indicator icon, charging process indicator, allowing you to check the charging level at any time;
It can be equipped with powerful microcomputer software, which has rich functions such as transmitting measurement results, storing and managing measurement values, statistical analysis of measurement values, printing measurement reports, etc., to meet the higher requirements of quality assurance activities and management;
The hardness measurement of special materials can be calibrated and tested using user materials.
Technical parameters of SF-TOPI high-precision Leeb hardness tester
|
measurement range |
(170-960)HLD,(19-651)HB,(13.5-101.7)HRB,(17.9-69.5)HRC,(59.1-88)HRA,(80-1042)HV,(30.6~102.6)HS Customizable measurement range for customers |
|
Measurement direction |
Any (360 °) |
|
Applicable Materials |
Steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile iron, cast aluminum alloy, copper zinc alloy (brass), copper tin alloy (bronze), pure copperforged steel |
|
Indication error and indication repeatability |
D-type impact device ± 6HLD (indication error) ± 6HLD (indication repeatability) |
|
Hardness scale |
Shore (HS), Leeb (HL), Brinell (HB), Rockwell (HRC, HRB, HRA), Vickers (HV), tensile strength σb8 types including (MPa) Display accuracy: 1HL, 1HV, 1HB, 0.1HRB, 0.1HRC, 0.1HRA, 0.1HS |
|
Range of upper and lower limit settings |
(170-960)HLD |
|
indication calibration |
Equipped with indication software calibration function |
|
data storage |
600 sets of measurement values |
|
data interface |
USB 2.0 |
|
Working Voltage |
7.4V lithium battery pack |
|
Operating Temperature |
-10℃~+55℃ |
|
Stable storage |
-20℃~+75℃ |
|
Overall dimensions |
210 × 85 × 45mm (host) |
|
weight |
0.6Kg |
Standard Configuration
|
![]() |
SF-TOPI high-precision Leeb hardness tester Table 1:
material
Hardness system
Impact device
D/DC
D+15
C
G
E
DL
Steel and cast steel
Steel and cast steel
HRC
17.9~68.5
19.3~67.9
20.0~69.5
22.4~70.7
20.6~68.2
HRB
59.6~99.6
47.7~99.9
37.0~99.9
HRA
59.1~85.8
61.7~88.0
HB
127~651
80~638
80~683
90~646
83~663
81~646
HV
83~976
80~937
80~996
84~1042
80~950
HS
30.1~110.1
33.3~99.3
31.8~102.1
35.8~102.6
30.6~96.8
Steel
forged steel
HB
143~650
CWT、ST
Alloy tool steel
HRC
20.4~67.1
19.8~68.2
20.7~68.2
22.6~70.2
HV
80~898
80~935
100~941
82~1009
HRA
60.7~92.6
HB
232~625
Stainless steel
stainless steel
HRB
46.5~101.7
HB
85~655
HV
85~802
GC. IRON
gray cast iron
HRC
HB
93~334
92~326
HV
NC、IRON
ductile cast iron
HRC
HB
131~387
127~364
HV
C.ALUM
cast aluminum alloy
HB
19~164
23~210
32~168
HRB
23.8~84.6
22.7~85.0
23.8~85.5
HV
83.2~648.2
BRASS
copper-zinc alloy
(Brass)
HB
40~173
HRB
13.5~95.3
BRONZE
copper-tin alloy
(Bronze)
HB
60~290
COPPER
pure copper
HB
45~315
SF-TOPI high-precision Leeb hardness tester Table 2:
|
Irregular impact device |
DC(D)/DL |
D+15 |
C |
G |
E (to be imported) |
|
|
impact energy Impact mass |
11mJ 5.5g/7.2g |
11mJ 7.8g |
2.7mJ 3.0g |
90mJ 20.0g |
11mJ 5.5g |
|
|
Ball head hardness: Ball head diameter: Ball head material: |
1600HV 3mm tungsten carbide |
1600HV 3mm tungsten carbide |
1600HV 3mm tungsten carbide |
1600HV 5mm tungsten carbide |
5000HV 3mm diamond |
|
|
Diameter of impact device: Length of impact device: Weight of impact device: |
20mm 86(147)/ 75mm 50g |
20mm 162mm 80g |
20mm 141mm 75g |
30mm 254mm 250g |
20mm 155mm 80g |
|
|
Test piece with high hardness |
940HV |
940HV |
1000HV |
650HB |
1200HV |
|
|
Average surface of test piece Roughness Ra: |
1.6μm |
1.6μm |
0.4μm |
6.3μm |
1.6μm |
|
|
Small weight of test piece: Directly measurable Stable support is required Need for dense coupling |
>5kg 2~5kg 0.05~2kg |
>5kg 2~5kg 0.05~2kg |
>1.5kg 0.5~1.5kg 0.02~0.5kg |
>15kg 5~15kg 0.5~5kg |
>5kg 2~5kg 0.05~2kg |
|
|
Small thickness of test piece Dense coupling Small depth of hardened layer |
5mm ≥0.8mm |
5mm ≥0.8mm |
1mm ≥0.2mm |
10mm ≥1.2mm |
5mm ≥0.8mm |
|
|
Ball indentation size |
||||||
|
When the hardness is 300HV |
indentation diameter indentation depth |
0.54mm 24μm |
0.54mm 24μm |
0.38mm 12μm |
1.03mm 53μm |
0.54mm 24μm |
|
When the hardness is 600HV |
indentation diameter indentation depth |
0.54mm 17μm |
0.54mm 17μm |
0.32mm 8μm |
0.90mm 41μm |
0.54mm 17μm |
|
When the hardness is 800HV |
indentation diameter indentation depth |
0.35mm 10μm |
0.35mm 10μm |
0.35mm 7μm |
-- -- |
0.35mm 10μm |
|
Scope of application of impact device |
DCType measuring hole or cylindrical tube; DLMeasuring slender narrow slots or holes; DType used for routine measurement |
D+15The contact surface is small and elongated, suitable for measuring grooves or concave surfaces |
CLow impact force, minimal damage to the tested surface, no damage to the hardened layer, suitable for measuring small lightweight components and surface hardened layers. |
GMeasurement of large, heavy, and rough surface castings and forgings. |
EMeasuring materials with extremely high hardness |
|