QL-225 Dynamic Static Ozone Aging Test Chamber

NegotiableUpdate on 02/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

QL-225 Dynamic Static Ozone Aging Test Chamber Product Usage: It can be used for rubber products such as vulcanized rubber, thermoplastic rubber, cable insulation sheaths, etc. Under static tension or continuous dynamic tension deformation, or under intermittent dynamic tension and alternating static tension deformation, it is exposed to a sealed and unlit air containing a constant ozone concentration and a constant temperature test chamber. The test specimen is tested for a predetermined time to evaluate the ozone aging resistance of the rubber from the degree of cracking or other performance changes that occur on the surface of the specimen.

Product Details

QL-225 Dynamic Static Ozone Aging Test Chamber

Product Introduction: This product is used to test the ozone aging resistance of rubber and its products. Ozone has a low content in the atmosphere, but it is the main factor causing rubber cracking. The ozone aging chamber simulates and strengthens the ozone conditions in the atmosphere, studies the effect of ozone on rubber, quickly identifies and evaluates the anti ozone aging performance of rubber and the protective effect of anti ozone agents, and then takes effective anti-aging measures to improve the service life of rubber products.

Product features: This ozone aging test equipment is made of materials and processed using advanced processing equipment in China. The surface of the shell is treated with spray coating, which is beautiful and smooth. The color matching is coordinated and the lines are smooth. The inner liner is designed to be a sealed space without direct sunlight during operation, where samples can be placed for aging tests. It can maintain a constant temperature difference of ± 2 ℃ during testing and is made of imported stainless steel plates. The indoor sample racks, fixtures, conduits, and other accessories are made of materials such as stainless steel that are not easily decomposed by ozone and affect ozone concentration. The sample holder can rotate 360 degrees with adjustable speed.

2、 Model and parameters

Product Model QL-100 QL-150 QL-225 QL-500 QL-010
Internal dimensions D × W × Hmm 450×450×500 500×500×600 500×600×750 700×800×900 1000×1000×1000
Dimensions D × W × Hmm 1100×870×1600 1100×920×1700 1150×1020×1850 1350×1220×2000 1650×1420×2100
temperature range A:0℃~70℃、 B:RT+10℃~70℃(Instructions at the time of ordering)
humidity range A:40%~98%R.H、B:85%~98%R.H
temperature fluctuation ≤±0.5℃
Temperature Uniformity ≤±2℃
temperature deviation ≤±1.5℃
humidity fluctuation +2、-3%R.H
heating rate 0.7~1.0℃/min
降温速率 Reduce the room temperature to 10 ℃ ≤ 20min/unrestricted
ozone concentration 10-1000pphm (low concentration), 1-500ppm (high concentration)Instructions for ordering
gas flow rate 12~16mm/S
Ozone sample rack Static and dynamic tensile test specimen racks
Sample rack speed 360 degree rotating sample holder (rotation speed 1r/min)
Time setting range 0-9999 hours
Power requirements AC220 AC380 (± 10%) V/50HZ three-phase five wire system
meet the standard GB/T7762-2014 Static test methods

QL-225 Dynamic Static Ozone Aging Test Chamber

3、 Test method

Static tensile test
The standard stipulates that the two ends of the sample should be clamped on a fixture, and a tensile elongation of 20% should be selected. The fixture should be installed on a rotating sample holder with a rotation speed between (20-25) mm/S. The test should be conducted at a temperature of (40 ± 2) ℃, a relative humidity of no more than 65%, and a specified ozone concentration. Check the cracking condition of the sample after the specified time. The general selection of ozone concentration is (50 ± 5) × 10-8.

4、 Ozone system:
1. The main component of the ozone generator is a silent discharge tube ozone generator (with the characteristics of small noise volume and high purity) with an output control accuracy of ± 10% for 4-20mA
2. Electrode cooling method: air cooling
3. Ozone generation gas source: direct air
4. The ozone detection probe consists of an imported CT electrochemical sensor, housing, electronic circuit board, shielded wire, etc
5. Ozone detection probe output signal: 4-20mA
6. Ozone detection probe collection accuracy: ≤± 5% F.S

5、 Refrigeration system:
1. Compressor: 1 set of fully enclosed French Taikang
2. Cooling method: air-cooled
3. Refrigerant: R404A, R23 (environmentally friendly)

6、 Heating, humidification, and dehumidification system:
A、 Heating system:
1. Adopting far-infrared nickel alloy high-speed heating electric heater
2. The temperature control output power is calculated by a microcomputer to achieve high-precision and high-efficiency electricity efficiency
B、 Humidification system:
1. Built in boiler steam humidifier
2. Equipped with automatic water level compensation and water shortage alarm system

7、 Equipment usage environment:
1. Environmental temperature: 5 ℃~+28 ℃ (average temperature within 24 hours ≤ 28 ℃)
2. Environmental humidity: ≤ 85% R.H
PS: The operating environment needs to be below room temperature of 28 degrees Celsius and well ventilated;
The machine should be placed 80 centimeters in front, back, left, and right, and no objects should be placed