Welcome Customer !

Membership

Help

Langxi Instrument (Shanghai) Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Portable SF6 mixture gas (mixture ratio) detector

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

LX-3100M portable SF6 mixed gas (mixture ratio) detector can achieve quantitative analysis of SF6/N2 and SF6/CF4 mixed insulation gas mixture ratios without changing the analysis conditions, and simultaneously monitor oxygen concentration. The power industry standard DL/T 1985-2019 "Detection Method for Mixing Ratio of Sulfur Hexafluoride Mixed Insulation Gas" drafted by Langxi Instrument and State Grid Anhui Electric Power Science Research Institute has been officially implemented since October 1, 2019. The jointly applied invention "A Gas Chromatography Detection Device for Mixing Ratio of Sulfur Hexafluoride Mixed Gas" has been made public.

Product Details

Details
brand private brand Instrument type portable
Origin category domestic price range Negotiable
Applicable Industries Universal Application field Medical and health care, environmental protection

LX-3100M portable SF6 mixed gas (mixture ratio) detector can achieve quantitative analysis of SF6/N2 and SF6/CF4 mixed insulation gas mixture ratios without changing the analysis conditions, and simultaneously monitor oxygen concentration. The power industry standard DL/T 1985-2019 "Detection Method for Mixing Ratio of Sulfur Hexafluoride Mixed Insulation Gas" drafted by Langxi Instrument and State Grid Anhui Electric Power Science Research Institute has been officially implemented since October 1, 2019. The jointly applied invention "A Gas Chromatography Detection Device for Mixing Ratio of Sulfur Hexafluoride Mixed Gas" has been made public.

1. Technical performance:

  • Analysis cycle:<6 minutes
  • Error:<3%
  • Stable time:<30 minutes
  • Working environment: -20~50 ℃
  • On site continuous detection capability: It can be moved for detection when turned on, and can run continuously for no less than 10 hours?

2. Technical parameters:

temperature control accuracy

±0.1℃

Instrument size

625×500×297mm

environment

temperature

-20~+50℃

working power supply

AC220V±10% 50Hz

humidity

≤ 95% without condensation

Optional built-in battery

Testing components

O2

N2

CF4

SF6

Detection limit (μ L/L)

5

5

5

50