Phoenix transmitter MINI MCR-BL-RPS-I-I in stock
MCR feeding isolation, screw connection, input signal: 0 (4).. 20mA, output signal: (0) 4... 20mA
size
Width 6.2 mm
Height 93.1 mm
Depth 102.5 mm
Back to top
environmental conditions
Environmental temperature (operating) -10 ° C... 60 ° C
Environmental temperature (storage/transportation) -20 ° C... 65 ° C
Back to top
Input data
Input description: Current input (sensor circuit)
Input quantity 1
Current input signal 0 mA... 20 mA
4 mA . .. 20 mA
Maximum input current of 28 mA
The input resistance of the input current is approximately 50 Ω
The power supply voltage of the transmitter UB is 4.5V, suitable for loads ranging from 0mA to 20mA
The power supply voltage range of the transmitter is 14.7 V DC... 25.5 V DC
Back to top
output data
Phoenix transmitter MINI MCR-BL-RPS-I-I in stock
Output Name: Current Output
Output quantity 1
Current output signal 0 mA... 20 mA
4 mA . .. 20 mA
Maximum output current of 28 mA
Load/Output Load current output ≤ 500 Ω (I=20 mA)
Fluctuations<20 mVrms (at 500 Ω)
Transmission behavior 1:1 corresponds to the input signal
Back to top
power supply
Rated supply voltage 24 V DC ± 10%
Power supply voltage range 19.2 V DC... 30 V DC
Maximum current consumption<40 mA
Power consumption<600 mW
Back to top
Wiring data
Connection method: Screw connection
Rigid wire with a minimum cross-sectional area of 0.2 mm ²
Rigid wire with the largest cross-section of 2.5 mm ²
Zui small wire cross-sectional AWG 26
Zui large wire cross-sectional AWG 12
Flexible wire with the smallest cross-section of 0.2 mm ²
Flexible wire with the largest cross-section of 2.5 mm ²
Stripping length 12 mm
Thread M3
Back to top
Overview
Number of channels 1
Maximum transmission error ≤ 0.2% (final value)
Typical transmission error ≤ 0.1% (final value)
The maximum temperature coefficient is less than 0.01%/K
Temperature coefficient, typical value<0.002%/K
Cut off frequency (3dB) is approximately 100 Hz
Step response (10-90%) 500 ms
Protection circuit transient protection
Electrical isolation complies with the basic isolation of EN 61010
Surge voltage category II
Pollution level 2
Rated insulation voltage 50 V AC/DC
Test voltage, input/output/power supply 1.5 kV (50Hz, 1min)
Electromagnetic compatibility complies with EMC regulation 2004/108/EC
Emission interference EN 61000-6-4
Anti interference EN 61000-6-2:2005
Color Green
Shell material PBT
Installation location is arbitrary
Compliance with CE standards
Fire protection of railway vehicles (DIN EN 45545-2) R22 HL 1-HL 2
Fire protection for railway vehicles (DIN EN 45545-2) R23 HL 1-HL 2
Fire protection for railway vehicles (DIN EN 45545-2) R24 HL 1-HL 2