Phoenix relay base PLC-BSC -24DC/21 in stock supply
Attention
Use restriction EMC: A-class products, refer to the manufacturer's statement in the download area
size
Width 6.2 mm
Height 93.1 mm
Depth 102.5 mm
environmental conditions
Environmental temperature (operating) -20 ° C... 65 ° C
Environmental temperature (storage/transportation) -40 ° C... 85 ° C
Input data
Input quantity 1
Configurable/Programmable Yes, Unconfigured
Voltage input signal 0 V... 10 V
0 V . .. 5 V
1 V . .. 5 V
2 V . .. 10 V
Current input signal 0 mA... 20 mA
4 mA . .. 20 mA
The maximum input voltage is 30V
Maximum input current of 50 mA
The input resistance of the input voltage is approximately 100 k Ω
The input resistance of the input current is approximately 50 Ω
output data
Output quantity 1
Configurable/Programmable Yes, Unconfigured
Voltage output signal 0 V... 10 V
0 V . .. 5 V
1 V . .. 5 V
2 V . .. 10 V
Current output signal 0 mA... 20 mA (if there are any different parameter setting requirements, please indicate them when ordering)
4 mA . .. 20 mA
Phoenix relay base PLC-BSC -24DC/21 in stock supply
The maximum output voltage is approximately 12.5 V
Maximum output current of 28 mA
Short circuit current is approximately 22 mA
Load/output load voltage output ≥ 10 k Ω
Load/Output Load current output<500 Ω (when 20 mA)
Fluctuations<20 mVSS (at 500 Ω)
< 20 mVSS (10 kΩ 时)
power supply
Rated supply voltage 24 V DC
The power supply voltage range is 19.2 V DC... 30 V DC (DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, order number 2869728) can be used to bridge the power supply. Can be clipped onto a 35 mm DIN rail that complies with EN60715 standard)
Maximum current consumption<19 mA (current output under load at 24V DC)
<9 mA (voltage output under load at 24V DC)
Power consumption<450 mW (current output)
<200 mW (voltage output)
Wiring data
Connection method: Screw connection
Rigid wire with a minimum cross-sectional area of 0.2 mm ²
Rigid wire with the largest cross-section of 2.5 mm ²
Zui small wire cross-sectional AWG 26
Zui large wire cross-sectional AWG 12
Flexible wire with the smallest cross-section of 0.2 mm ²
Flexible wire with the largest cross-section of 2.5 mm ²
Stripping length 12 mm
Thread M3
Overview
Number of channels 1
Maximum transmission error ≤ 0.1% (final value)
<0.4% (without mediation)
The maximum temperature coefficient is less than 0.01%/K
Temperature coefficient, typical value<0.002%/K
Cut off frequency (3dB) is approximately 100 Hz
Step response (10-90%) is approximately 3.2 ms
Protection circuit transient protection
Electrical isolation complies with the basic isolation of EN 61010
Surge voltage category II
Pollution level 2
Rated insulation voltage 50 V AC/DC
Test voltage, input/output/power supply 1.5 kV (50Hz, 1min)
Electromagnetic compatibility complies with the Electromagnetic Compatibility Directive
Emission interference EN 61000-6-4
When the noise resistance EN 61000-6-2 is disturbed, it may be the smallest deviation.
Color Green
Shell material PBT
Installation location is arbitrary
Assembly instructions: The T-shaped connector provides bridging power supply for the module. Can be clipped onto a 35 mm DIN rail that complies with EN 60715 standard.
Compliance with CE standards
ATEX II 3 G Ex nA IIC T4 Gc X
UL, UL 508 certification in the United States/Canada
Class I, Div. 2, Groups A, B, C, D T5
GL GL EMC 2 D
Fire protection of railway vehicles (DIN EN 45545-2) R22 HL 1-HL 2
Fire protection for railway vehicles (DIN EN 45545-2) R23 HL 1-HL 2
Fire protection for railway vehicles (DIN EN 45545-2) R24 HL 1-HL 2
EMC Data
Name: Electromagnetic RF Field
Standard/regulation EN 61000-4-3
The typical deviation of the final value within the measurement range is 5%
Name: Fast Transient (Pulse Train)
Standard/regulation EN 61000-4-4
The typical deviation of the final value within the measurement range is 5%
Name Conducted Interference
Standard/regulation EN 61000-4-6
The typical deviation of the final value within the measurement range is 5%
standards and specifications
Electromagnetic compatibility complies with the Electromagnetic Compatibility Directive
Emission interference EN 61000-6-4
Connect according to standard CUL
Standard/regulation EN 61000-4-2
Name: Electromagnetic RF Field
Standard/regulation EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
Name Conducted Interference
Standard/regulation EN 61000-4-6
Electrical isolation complies with the basic isolation of EN 61010
Compliance with CE standards
ATEX II 3 G Ex nA IIC T4 Gc X
UL, UL 508 certification in the United States/Canada
Class I, Div. 2, Groups A, B, C, D T5
GL GL EMC 2 D
Fire protection of railway vehicles (DIN EN 45545-2) R22 HL 1-HL 2 HL 1-HL 2 HL 1-HL 2 HL 1-HL 2
Fire protection for railway vehicles (DIN EN 45545-2) R23 HL 1-HL 2 HL 1-HL 2 HL 1-HL 2
Fire protection for railway vehicles (DIN EN 45545-2) R24 HL 1-HL 2 HL 1-HL 2 HL 1-HL 2
Fire protection for railway vehicles (DIN EN 45545-2) R26 HL 1-HL 2 HL 1-HL 2 HL 1-HL 2
Environmental Product Compliance
China RoHS environmental protection usage period=50
For more details on harmful substances, please refer to the "Manufacturer's Statement" in the "Download Area"
Classification
eCl@ss
eCl@ss 4.0 27210120
eCl@ss 4.1 27210120
eCl@ss 5.0 27210120
eCl@ss 5.1 27210120
eCl@ss 6.0 27210120
eCl@ss 7.0 27210120
eCl@ss 8.0 27210120
eCl@ss 9.0 27210120
ETIM
ETIM 4.0 EC002653
ETIM 5.0 EC002653
ETIM 6.0 EC002653
UNSPSC
UNSPSC 6.01 30211506
UNSPSC 7.0901 39121008
UNSPSC 11 39121008
UNSPSC 12.01 39121008
UNSPSC 13.2 39121008