Welcome Customer !

Membership

Help

Guiyang Xuetong Instrument Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Guiyang Xuetong Instrument Co., Ltd

  • E-mail

    2435669371@qq.com

  • Phone

    17785156586

  • Address

    16th Floor, Building D, Century Jinyuan International Wealth Center, Guanshanhu District, Guiyang City, Guizhou Province

Contact Now

PHS-3B acidity meter

NegotiableUpdate on 04/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

PHS-3B and pHS-3C are general-purpose acidimeters, pHS-2C is an economical acidimeter, and pHS-25 is a simple acidimeter. Based on common models in the market, they have made significant improvements in intelligence, measurability, usage environment, and appearance structure, with higher cost-effectiveness. It can be widely used for continuous monitoring of pH values in solutions such as thermal power, chemical fertilizers, metallurgy, environmental protection, pharmaceuticals, biochemistry, food, and tap water.

Product Details

PHS-3B/3C/2C/25 acidity meter

pHS-3B、pHS-3CpH meterBelonging to the general acidity meter, pHS-2C belongs to the economical acidity meter, and pHS-25 belongs to the simple acidity meter. Based on common models in the market, they have made significant improvements in intelligence, measurability, usage environment, and appearance structure, with higher cost-effectiveness. It can be widely used for continuous monitoring of pH values in solutions such as thermal power, chemical fertilizers, metallurgy, environmental protection, pharmaceuticals, biochemistry, food, and tap water.

PHS-3B/3C/2C/25 acidity metertechnical indicators
Display mode: Double row digital tube (pHS-2C, pHS-25 are single row)
Measurement range: -2~18.00pH, -1999~1999mV, 0~99.9 ℃
Resolution: 0.01pH, 0.1mV, 0.1 ℃
精 度: pHS-3B、3C ±0.01pH,±1mV ,±0.3℃
pHS-2C ±0.02pH,±0.2%FS(mV)
pHS-25 ±0.05pH,±0.5%FS(mV)
Temperature compensation range: automatic/manual 0-99.9 ℃
Temperature compensation: Nernst electrode slope temperature compensation, converted to 25 ℃ for pure water and ammonia added ultrapure water
Input impedance:>1012Ω
Communication interface: RS232 bidirectional communication
Power supply: AC220V ± 22V, 50Hz ± 1Hz, external power supply
Working conditions: ambient temperature 0-60 ℃, relative humidity ≤ 90 ℅
Power off storage:>5 years
Calibration method: One point calibration, two-point calibration
Size and weight: 202x202x68mm, 1.0Kg
PHS-3B/3C/2C/25 acidity meterStandard ConfigurationOne pHS-XX secondary meter, one HT5 power supply, one T226 composite electrode, one T22 temperature electrode (only available for pHS-3B), one set of electrode holder, and one set of standard buffer solution.

PHS-3B/3C/2C/25 acidity meterMain Features
Double row digital tube: displays pH value/mV and temperature value respectively.
Microcomputerization: Using high-performance CPU chips, high-precision AD conversion technology, and SMT surface mount technology, it completes multi parameter measurement, temperature compensation, instrument self-test, high accuracy, and good repeatability.
High reliability: Single board structure, touch sensitive buttons, no switch knob.
25 ℃ conversion: Nernst electrode slope temperature compensation, conversion for pure water and ammonia added ultrapure water at 25 ℃.
Input impedance>1012Oh.
Waterproof and anti-corrosion design.
Automatic conversion of standard solution temperature: The temperature curve of the standard solution is pre stored, and the pH value of the standard solution at the set temperature is automatically converted during calibration.
Automatic identification of incorrect calibration: If the user uses standard buffer solution incorrectly during calibration, the instrument will automatically prompt.
Network function: RS232 bidirectional communication, compatible with printer or TLab1.0 communication and data processing software.
Industrial control watchdog: ensures instruments do not crash
Automatically prompt measurement endpoint


The main differences among the four models are: 1. Different accuracies. 2. pHS-3C, pHS-2C, and pHS-25. Temperature compensation can only be manually inputted. 3. pHS-2C and pHS-25 are displayed on a single row digital display
PHS-3B/3C/2C/25 acidity meterOrdering Guide:It is necessary to inform the measured medium for easy electrode selection.