Welcome Customer !

Membership

Help

Changzhou Kemai Experimental Instrument Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products
Product Categories

Changzhou Kemai Experimental Instrument Co., Ltd

  • E-mail

    km@czkemai.net

  • Phone

    13921012701,18921020220

  • Address

    Jinsheng East Road, Jintan District

Contact Now

Ozone aging test chamber

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Ozone aging test chamber 1. Purpose of ozone aging test chamber 1. The low content of ozone in the atmosphere is the main factor causing rubber cracking. The ozone aging chamber simulates and strengthens the ozone conditions in the atmosphere, studies the effect of ozone on rubber, quickly identifies and evaluates the anti ozone aging performance of rubber and the protective effect of anti ozone agents, and then adopts anti-aging measures to improve the service life of rubber products

Product Details

臭氧老化试验箱.png

Ozone aging test chamber

1、 Ozone aging test chamberpurpose

lThe low content of ozone in the atmosphere is the main factor causing rubber cracking. The ozone aging chamber simulates and strengthens the ozone conditions in the atmosphere, studies the effect of ozone on rubber, and quickly identifies and evaluates the anti ozone aging performance and protective effectiveness of rubber anti ozone agents. Therefore, anti-aging measures are taken to improve the service life of rubber products.

2、 Ozone aging test chambermeet the standard

lJIS K 6259ASTM1149 ISO1431 GB/T7762 GB/T13642wait

3、 Ozone aging test chamberEquipment model and specifications(User defined non-standard size)

model

Studio size (DxWxHmm)

KM - CLX -100

450 × 450 × 500

KM - CLX -150

500 × 500 × 600

KM - CLX -250

500 × 650 × 700

KM - CLX -500

700 × 800 × 900

KM - CLX -800

800 × 1000 × 1000

KM - CLX -010

1000 × 1000 × 1000

KM - CLX -015

1000 × 1000 × 1500

4、 Technical parameters of ozone aging test chamber

lModel:KM - CLX

lSpecifications:See above

lozone concentration: 0-1000 pphm (set for direct reading)

lOzone concentration deviation: Nationalmark10%

lTest chamber temperature:Measurement range: Room temperature~+80℃

lTemperature uniformity:±2℃

lRelative humidity: measurement rangeenclose60%above

lRotation speed of sample holder: 050mm/s

lDynamic pull-up frequency:0.5Hz

lNew sample holder(Each fixture can be used to install test pieces, and the tensile strength can meet the requirements of Type I dumbbell pads and actual workpieces)

lTest gas flow rate:0-60L/min

fiveOzone aging test chamberStructural characteristics and configuration

lShell cold plate spray coating/Stainless steel inner liner.

lAIDigital intelligent programmable controller.

lGas flow meter, controlling the gas flow rate at all levels.

lSilent discharge ozone generator, equipped with“QUA”Non dispersive ultraviolet ozone detector

l(Reliable and popular methods for detecting ozone worldwide).

lBill-Lambert principle measurement application software.

lEquipped with gas purifier, constant temperature bath,

l Activated carbon absorption and silica gel drying tower.

lThe airflow containing ozone is parallel to the sample.

lOptional remote monitoring software(availablePCMachine printed test data)

lEquipped with interfaces for classic chemical testing of ozone concentration.

lStainless steel test chamber that meets world standards and fully enclosed gas circuit for producing ozone through silent discharge,The entire generation and capture of ozone gas is a closed circuit, ensuring personal reliability.

lin1000pphmSet the ozone concentration arbitrarily within the specified range.

lVariable speed motor driven sample holder device(Satisfy the static tensile test,The running trajectory of the specimen conforms to the principle of cycloid trajectory)

lOzone concentration automatic digital display controller.

lDual beam“QUA”Non dispersive ultraviolet ozone detector.

lDigital display automatic online measurement.

lLeave a metrological verification and calibration interface.

lozone concentration/Temperature and humidity setting valuescontrolPIDSelf integrationFixed, easy to operate and reliable.

l3Dai Bill-Lambert measurement application software.

lReliable door lock control system

sixOzone aging test chamberprotective device

lWhen the control system detects the action of the following protective devices (single row), it should be able to automatically cut off the entire system and give an alarm prompt.

lOvertemperature protection device

lReverse phase,Phase loss protection device

lNon fuse switch overload protection

lOverload protection for blower motor

lHeater short circuit

lLine fuses and fully sheathed terminals.

7Ventilation aging test chamberquality assurance

lpublicThe company has passedISO90012008Quality management system certification, strictly follow the management system to organize product design and production

lOn site installation and debugging of equipment, and training of operating personnel for customers.

lIf the product cannot function properly due to manufacturing quality issues within twelve months from the date of shipment, provided that the user complies with the product installation and usage rules, our company will provide free repairs for the user.

lFor products outside the warranty period, our company provides long-term technical services.

lAfter sales service response time:24Response within hours