SMOMAT 010It is a universal freezing point osmometer used to determine the molar molecular weight of benzene solution and the total osmotic pressure of aqueous solution.OSMOMAT 010It is based on the fact that it has been used for many years, especially in the medical field, and has a good reputationOSMOMAT 030Made using the same measurement method.Osmomat010Suitable for detecting freezing point range of-5°C-10°CThe freezing points of aqueous and organic solutions.
OSMOMAT 010application
·Measure the osmotic pressure of an aqueous solution
For measuring osmotic pressure,OSMOMAT 010Firstly, calibrate with water and a solution of known osmotic pressure. Then immediately measure with the sample solution under the same conditions. The measurement results can be directly read on the display screenmOsmol/kg
·Measure the molar molecular weight
FirstOSMOMAT 010Correct with pure solvent and a solution of known molar concentration. thenOSMOMAT 010Adjust the zero point of the solvent to10℃ -5℃scope The concentration of the calibration solution is1 -10×10E-2 mol/kgThe measurement has a sensitivity of *. the measurement result(number)Divided by the molar concentration value, represents the measurement cell constant. For sample measurement, prepare based on the expected molar molecular weight5-140g/kgSolution with solvent concentration. The value obtained from this sample solution is also divided by the corresponding concentration to calculate the sample quotient. Divide the sample merchant by the pool constant to directly obtaing/molThe result. For molecular weights below1000g/molUnder normal circumstances, single point measurement is sufficient for measuring. Considering the measurement values of non-polar substances in the low molecular weight range/The non-linear characteristics of concentration ratio should be measured for at least three gradient concentrations. The results obtained in this way must be processed using statistical linear regression.
Product Features:
*Controlled by microprocessor
·Response time approximately1min
·Easy to operate
·Smaller sample volume
·auto-correction
Osmomat 010 Main technical parameters
parameter/model |
OSMOMAT 010 |
sample size |
50μl – 30μl |
Time required for measurement |
about1minute |
repetitiveness |
<±0,5%or. <±2Digit number(50μl) |
display |
4,5Digit number |
measurement range |
Yoda in benzene3000 mOsmol / kg, about40-5000 Dalton |
analytical ability |
In benzene1 mOsmol / kg, about 3 Digit number/ mMol/kg |
Crystallization method |
Automatic injection of ice crystals into the solution |
cooling |
By utilizing air thermal diffusion2Group independent ear patch(Peltier)Air-cooled cooling system |
ambient temperature |
10oC-35oC |
built-in printer |
AlphaDigital printer, automatic registration of measurement results, data, time and4Sample number with digits,4Measurement result of digits, normal paper43mmAutomatic paper feeding or button, replaceable ink cartridge, button on/Turn off the printing function and clear the printing error message. |
analog output |
through standards5Hole socket, output voltage1mV/Digit numbertThe potentiometer recorder continuously records the temperature |
RSdata output |
RS 232CStandard socket |
power supply |
230V(±30V),50—60Hz,120VA |
weight |
about7kg |
Standard Configuration |
100A disposable plastic testing tube |