The TACH-GW-0013 series online multi parameter analyzer adopts a self-developed design with repeatability ≤ 0.15% at 0.5mL and a corrosion-resistant flow path design;

Product Details

TACH-GW-0013 seriesOnline multi parameter analyzerIt is a new instrument that integrates computer automation control technology and a novel and simple chemical flow path. Humanized design, simple operation, using different measurement principles for laboratory analysis or industrial production process water, sewage, urban and urban domestic sewage, as well as relevant parameters in surface water samples such as rivers, lakes, seas, etc(Detection of fluoride, sulfide, nitrite, and volatile phenols.

TACH-GW-0013 seriesOnline multi parameter analyzerPerformance Characteristics

Adopting modular design, each component operates independently, improving the efficiency of the instrumentOptical acquisition system;

The application of components from foreign manufacturers in independently developed technologies ensures the repeatability and stability of instrument measurements, reducing instrument failure rates;

Integrated anti control, positioning, and data acquisition system, users can understand the current status of the instrument at any time through various methods;

The instrument can automatically identify water samples to ensure normal operation of the instrument;

Adopting independent research and development in0.5mLRepeatability under certain conditions≤0.15%Design and corrosion-resistant flow path design;

Adopting an eight ring valve system and independently developed strong acid and strong corrosive liquid measurement technology, it has a long service life, stable light intensity, and can be automatically calibratedLEDLight source;

Using intelligent optocoupler judgment combined with liquid level detection technology to accurately determine the amount of reagent used;

Intelligent controllable gas-liquid gentle backwash pretreatment system, precisionPIDThe temperature control dual system redundancy technology, two-point calibration or intelligent single point calibration make instrument operation and maintenance simpler, with independent channels and automatic standard liquid verification function.

technical indicators

Measuring range 0.02~10mg/L

Indication error ±5%F.S

Measurement drift: zero point(24h):±0.05mg/L

Range(24h):±5%F.S

heavy again Sex:≤3%

Detection limit:0.05mg/L

Measurement mode: continuous, hourly, manual, trigger start

Maintenance work: replace reagents and maintain instruments(1month1Next time)

Self setting: calibration interval, resolution time

Communication method:2road420mAoutputRS485RS232

Power supply AC 220V±10 50HZ

wait Machine:15W

transport that 's ok:44W