E-mail
781801536@qq.com
-
Phone
13165062660
-
Address
No. 30 Xianshan East Road, Chengyang District, Qingdao City, Shandong Province
Qingdao Rongguang Electronic Technology Co., Ltd
781801536@qq.com
13165062660
No. 30 Xianshan East Road, Chengyang District, Qingdao City, Shandong Province
QingdaoRongguang Electronic Technology Co., Ltd
Direct person in charge of product sales: An Chao
mobile phone131 - 6506 - 2660
Please feel free to call for consultation at any time. Thank you
RGYQ-3D multifunctional (hydrogen chloride, hydrochloric acid mist, sulfuric acid mist, fluoride) samplingrod
Product OverviewMulti functional fixed pollution source smoke and gas sampling gun
RGYQ-3D multifunctional (hydrogen chloride, hydrochloric acid mist, sulfuric acid mist, fluoride) samplingrodMainly used for the collection of hydrogen chloride, hydrochloric acid mist, sulfuric acid mist, and fluoride in fixed pollution source emissions. the samplingrodAdopting a full heating method ensuresrodThe body does not produce condensed water, and the collected gas is heated by a PTFE lined tube at a constant temperaturerodAfter passing through a PTFE membrane filter and an impact absorption bottle, particulate chloride and gaseous hydrogen chloride, hydrochloric acid mist, sulfuric acid mist, fluoride, etc. are collected separately. Among them, particulate chloride is used47mm filter membrane collection, gaseous hydrogen chloride, hydrochloric acid mist, sulfuric acid mist, fluoride are collected using absorption bottles, and parameters such as smoke flow rate and smoke temperature can be measured during sampling.
Execution standardsMulti functional fixed pollution source smoke and gas sampling gun
GB16157-1996 "Determination of particulate matter and sampling methods for gaseous pollutants in exhaust gas from fixed sources" HJ/549-2016 "Determination of hydrogen chloride in ambient air and exhaust gas by ion chromatography"
HJ/T47-1999 Technical Conditions for Smoke Samplers
HJ/T48-1999 Technical Conditions for Smoke and Dust Samplers
HJ 544-2016 "Determination of Sulfuric Acid Mist in Waste Gas from Fixed Pollution Sources - Ion Chromatography Method"
HJ 67-2001 "Determination of Fluoride in Air Fixed Source Waste Gas - Ion Selective Electrode Method"
Features
samplingRod rodThe body adopts constant temperature heating, lined with PTFE tube, and the entire sampling gas path is made of PTFE material.
samplingrodUsing a PTFE membrane filter with a one-way valve for filtration, the diameter of the filter membrane is47mm。
The membrane filter adopts constant temperature heating, with a control range of (0-120) ℃, adjustable at any point.
rodThe body adopts full heating and temperature control throughout the process(0~199) ℃, adjustable at any point.
Equipped with an absorption bottle electric refrigeration box that can hold a mixture of ice and water, with a controlled temperature of (3-5) ℃.
At the same time of sampling, parameters such as smoke flow rate and smoke temperature can be measured.
rodThe body length can be customized according to customer needs.
Equipped with a three legged bracket that can adjust the height, used to support samplingrodAnd absorption bottles.
technical indicators
Main parameters |
parameter range |
Main parameters |
parameter range |
|
|
|
|
samplingrodlength |
1.5 meters (customizable) |
rodBody heating temperature |
(0~199) ℃, adjustable |
|
|
|
|
Pitot tube coefficient |
0.84 |
Smoke temperature sensor (Pt100) temperature |
(0~500)℃ |
|
|
|
|
Requirements for measuring hole diameter |
≥Ф75mm |
Heating temperature of membrane filter |
(0-120) ℃, adjustable |
|
|
|
|
working power supply |
DC24V/10A |
working power |
220W |
|
|
|
|