Beijing Ying'an Meicheng Scientific Instrument Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Beijing Ying'an Meicheng Scientific Instrument Co., Ltd

  • E-mail

    michem@126.com

  • Phone

    13051605051

  • Address

    Beijing Changping District Beiqing Road Zhongguancun Life Science Park Boya Cc

Contact Now

MC/BP Cooling Water Circula

NegotiableUpdate on 03/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Product features: Since its launch in 1995, the MICHEM MC series refrigeration water cycle unit has undergone continuous development, from improving outdated products at home and abroad to replicating * products, and then undertaking the national 15th Five Year Plan research and development project, independent innovation. Currently, there are two major series: start stop and variable frequency, and variable frequency control can be used for cooling capacity below 7000W. The MC series chilled water cycle generator can generate constant temperature, constant current, and constant pressure cooling water, suitable for various instruments and equipment that require water cooling and constant temperature. The product principle and technology are becoming increasingly mature, and the performance is applicable and reliable, enjoying a high reputation in the market.
Product Details

Instrument Introduction

If the heat generated by the heating components in the analytical instrument is not dissipated in time during operation, the instrument cannot work and must be cooled with cooling water. In the past, the cooling of analytical instruments often used the method of running tap water for a long time. Under normal circumstances, the consumption of tap water is based on10L/minCalculate, if working every day8In hours, the annual water consumption is approximately1440Ton, greatly wasting precious water resources and poor refrigeration effect; For areas with hard water quality, the problem of "scaling" can also affect the normal use of instruments. Therefore, the instrument cooling method commonly used at present is the circulation of cooling water.

MICHEM MCSeries Cooling Water Recirculators1995Since its launch in the market, after continuous development, it has gone from improving backward products at home and abroad to replicating * products, and then undertaking national 15th Five Year Plan research projects and independent innovation. Currently, there are two major series: start stop and variable frequency, with a cooling capacity of7000WThe following can all be controlled by frequency conversion.MCThe series of chilled water circulators can generate constant temperature, constant current, and constant pressure cooling water, suitable for various instruments and equipment that require water cooling and constant temperature. The product principle and technology are becoming increasingly mature, and the performance is applicable and reliable, enjoying a high reputation in the market.

Instrument Features

Ø cooling water temperature5-35Within the range, it can be adjusted according to requirements. By changing the frequency of the compressor, the input and output power of the refrigeration system can be automatically adjusted to achieve temperature control, energy saving, and energy-saving compared to the start stop type with the same refrigeration capacity30%The above.

Ø The key components of the refrigeration system, such as compressors and circulating fans, are imported products. When the temperature is balanced, the compressor runs at low speed with minimal noise; Adopting imported circulation pump, with large circulation flow and maximum pressure reaching7.0barabove; Pressure adjustable.

Ø Micro processing chip control, high control accuracy, stable and reliable performance, andPIDCombining temperature control technology to achieve precise temperature control(±0.1).

Ø Input power during compressor start-up20Within seconds, gradually increasing from small to largesoft startThis avoids the high current surge during the start-up of a fixed speed compressor and extends the lifespan of the entire machine.

Ø By changing the frequency of the compressor to achieve temperature control, the input and output power of the refrigeration system can be automatically adjusted.

Instrument technical parameters

Technical parameters of Meicheng MC/BP variable frequency chilled water circulation system

model

MC-1000C/BP

MC-1600C/BP

MC-2500C/BP

MC-3500C/BP

MC-7000C/BP

refrigeration capacity

1000W

1600W

2500W

3500W

7000W

Temperature control range

535

535

535

535

535

Temperature control accuracy

± 0.1

± 0.1

± 0.1

± 0.1

± 0.1

backlash

0

0

0

0

0

Control method

PID

PID

PID

PID

PID

compressor

Variable frequency type

Variable frequency type

Variable frequency type

Variable frequency type

Variable frequency type

Water tank capacity

15L

15L

15L

20L

20L

Installation method

Integrated mobile type

Integrated mobile type

Integrated mobile type

Split fixed type

Split fixed type

input power

850W

850W

850W

1300W

2300W

Power requirements

220V 10A

220V 10A

220V 10A

220V 10A

220V 10A

pump flow rate

6L/min

6L/min

6L/min

6L/min

6L/min

Device dimensions

W×D×H

(mm)

700×485×780

700×485×780

700×485×780

indoor unit710×445×690

outdoor unit800×280×600

indoor unit

710×445×690

outdoor unit1020×340×830

Outlet pressure

7bar

7 bar

7bar

7bar

7 bar

remark

The listed configurations are standard, and a booster water pump and water tank can be selected according to the actual needs of the user.

For more information, please search:/