- Phone
-
Address
101, Building 1, No. 199 Jiangkai Road, Minhang District, Shanghai
Shanghai Wenyi Optoelectronics Technology Co., Ltd
101, Building 1, No. 199 Jiangkai Road, Minhang District, Shanghai

The flagship product of Wenyi Optoelectronics, MAX2000-Pro, has a fiber optic spectrometer (also known as a portable spectrometer/miniature spectrometer) with high sensitivity, high quantization efficiency, and high dynamic range, and can respond to the deep ultraviolet band (~185-300nm). MAX2000-PRO uses a Hamamatsu back illuminated area array FFT-CCD, which can be perfectly applied in fields that require high quantization efficiency and wider spectral range.
The MAX2000-PRO perfectly combines the Hamamatsu array back illuminated FFT-CCD and EX grating, which have many advantages such as low electronic noise, high UV sensitivity, high quantization efficiency, high dynamic range, and ultra wide spectral range. It is the preferred product for many fields with weak light detection, UV sensitivity, and wide spectral range requirements.
It has a rich wavelength range of 185-1150 nm.
The MAX2000-PRO is available in regular, EX full spectrum, and DUV deep ultraviolet versions.
| Mechanical parameters | |||
| project | value | ||
| Size (millimeters) | 115 * 158 * 46.5 | ||
| Weight (g) | 800 | ||
| Detector parameters | |||
| project | value | ||
| detector | Hamamatsu S10420-1106 backlit, surface array FFT-CCD | ||
| Detector response range (nm) | 185-1100 | ||
| Effective pixels | 2048 X 64 | ||
| Pixel size (μ m) | 14 square meters | ||
| Detector area (in millimeters) | Width 28.672, height 0.896 | ||
| A/d conversion | 16 bit, 500kHz | ||
| Integral time | 11 milliseconds -5 seconds | ||
| Sensitivity (V/lx · s) | ~0.32 counts/e- | ||
| Optical system parameters | |||
| project | value | ||
| optical system | F / 4,f / 4, Symmetric cross optical path | ||
| Focal length (millimeters) | 100 millimeters | ||
| Slit size (μ m) | 5,10,25,50100200, etc., or no slit (customized) | ||
| grating | Scratched gratings or holographic gratings with different parameters and the same shining wavelength (customizable) | ||
| Cylindrical mirror small size | option | ||
| Eliminate secondary spectral filter | Bandpass or long wave pass filter to eliminate secondary spectra | ||
| Fiber optic cables and their connection interfaces | NA 0.22,SMA905 | ||
| Spectral parameters | |||
| project | value | ||
| Spectral wavelength testing range | Dependent on grating selection, 185-1100nm | ||
| Spectral resolution (nm) | ~0.07-8.4 nm FWHM (determined by grating constant, slit width, and detector model, etc.) | ||
| SNR | 500:01:00 (full range) | ||
| Wavelength tolerance | Prince of Wales Hospital * 20% | ||
| Optical platform | Focal length 100mm, symmetrical cross CT optical path | ||
| dynamic range | 6000:1 | ||
| Stray light | <0.05% at 600nm;<0.10% at 435nm | ||
| Correction of linearity: | > 99.8% | ||
| Electrical Parameters | |||
| project | value | ||
| power waste | 500 mA×5 V DC | ||
| Data transmission rate | Full spectrum reading into memory via USB 2.0 interface takes 3.0 ms | ||
| Computer configuration | |||
| operating system | window | ||
| Data transmission interface | USB 2.0(480Mbps), Compatible with USB 1.1 | ||
| Pre configured system parameters | |||
| Component Name | Customized component parameters | remarks | |
| slit | Width (micrometers) | 10, 20, 50, 100, etc | |
| grating | Linear logarithm (L/mm) | 300,400,500,600,800,1200,1800 | |
| Spectral response range (nm) | 185-1100 (user-defined, with a spectral response range of approximately 650nm for a 600 line pair/mm grating) | ||
| Fiber optic | Core diameter (μ m) | 9, 50, 200, 400, 600, 1000, etc | |
| Spectral response range (nm) | 190~2500 | ||
| Outer protective layer | Normal or enhanced protective sheath | ||
| Interface type | SMA 905 (standard) or FC, TA, TB, TC, etc | ||
| detector | model | Hamamatsu S10420-1106 | |
| Optional components | |||
| Component Name | remarks | ||
| light source | Used for measuring or wavelength calibration of a wide spectral response range, such as deuterium halogen two in one light source, halogen tungsten lamp, deuterium lamp or mercury argon lamp light source | ||
| Integral ball | Used to achieve uniform light output of the light source | ||
| Reflectance measurement attachment | Accessories for reflectance spectroscopy measurement, such as standard reflectance standard whiteboards, aluminum mirrors, miniature reflectance platforms, special fixtures, etc | ||
| Transmittance Measurement Attachment | Accessories used for transmission spectroscopy measurement, such as sample holders, transmission brackets, various colorimetric dish brackets, flow sample pools, etc | ||
| Fluorescence excitation light measurement attachment | Accessories for fluorescence excitation light measurement, such as 4-way colorimetric dish holder, etc | ||
| Packaging List | |||
| Component Name | quantity | ||
| Wyoptics miniature spectrometer | MAX2000-PRO | ||
| Fiber optic with SMA905 interface | Optional selection | ||
| USB data cable | 1 | ||
| Software and Development Kit SDK CD | 1 | ||
|
|
![]() |
| MS Microscopic Spectral Analyzer | PC2000 industrial grade spectrometer | FIB Wenyi Optoelectronics Quartz Fiber |