E-mail
2048748897@qq.com
-
Phone
15153602766
-
Address
East side of Hehua South Road, Yishuhe Town, Xiangtan County (Tianyi Demonstration Zone)
Hunan Yipeng Environmental Protection Technology Co., Ltd
2048748897@qq.com
15153602766
East side of Hehua South Road, Yishuhe Town, Xiangtan County (Tianyi Demonstration Zone)
Liaoning Liaoyang wall mounted slow-release disinfectant for outpatient use
1、 OperationInstructions
1)Slow-release sterilizer:The chemical reaction automatic slow-release delayed pressure chlorination process is adopted, using strong chlorine solid prescriptions with a content of over 75% as the main raw material. The disinfectant produced by reasonable mixing of water and chemicals is added to the water tank, well, pipeline, and sewage tank to react with the contacted water to achieve the sterilization effect.
2)Installation: The water inlet is connected to the power water source, and the water pressure requirement is above 0.05MPa. If installed on a pipeline, additional equipment needs to be added, and the inlet is connected to the sterilization water source such as the water tank and well.
3)Dosing: Close the inlet valve, open the drain valve, drain the water from the box, open the medication dispensing cover, add the required amount of medication, and then close the pharmacy cover again and tighten it.
4)Operation: Gradually open the inlet valve and dosing valve, and adjust the flow meter according to the volume. Before each dosing, open the inlet valve and drain valve and flush them clean to prevent blockage.
5)Residual chlorine detection: On the second day of use, residual chlorine in the factory water was detected. Gradually adjust the dosage according to the size, and after three days, check that there is no residual chlorine in the pipeline network.
2、 Product Features
Using dissolution method,Automatic slow-release,Design of pressure chlorination process,Using solid agents containing over 80% CL as the main raw material,Disinfectant produced by rational mixing and slow-release of water and chemicals,Put it into the required water tank (well) and fully contact it with water for sterilization and disinfection. The equipment is welded with high-quality PVC sheets and can be used normally for up to 10 years.
3、 Installation instructions
1Inlet, connecting power water, water pressure requirement below 0.20MPa,If it exceeds the rated water pressure,A pressure reducing valve must be installed in advance.
2The outlet (disinfectant mixture) directly contacts the raw water in the water tank (well) or is connected to the inlet pipe of the water pump.
3Add medication (CL), remove the top cover, rotate the medication chamber cover, add the required amount of medication, cover and seal; Connect the power supply,

4Turn on the indicator power switch (indicator light on) to start (non powered equipment does not require power). Gradually open the inlet ball valve and adjust it from small to large to the required flow rate of L/min. Residual chlorine monitoring: Monitor the residual chlorine in the factory water on the second day, adjust the dosage and flow rate based on the results, and monitor the residual chlorine at the end of the pipeline network three days later.
4、 Technical specifications
Including raw water pump, quartz sand filter, activated carbon filter, and precision filter. Its main function is to remove particles, colloids, organic matter, chromaticity, residual chlorine, and bacteria from raw water.
1)mechanical filter
Working principle: A mechanical filter is a pressure filter that uses refined quartz sand filter material filled in the filter. When the incoming water flows through the filter layer from top to bottom, suspended solids and adhesive paper particles in the water are removed, thereby reducing the turbidity of the water
When the device runs for a certain period of time, it stops running for backwashing. Adopting water backwashing with a backwashing time of 15-20 minutes. Regular manual control.
The turbidity of the water produced by mechanical filters is generally below 2 degrees, and the SDI (Pollution Index) can generally be below 4 degrees.
2)Activated carbon filter
Working principle: The adsorption capacity of activated carbon is mainly based on physical adsorption, and it can also perform some selective adsorption, namely chemical adsorption. Activated carbon is the main absorbent widely used in water treatmentpreviouslyDuring the activation process, various shapes and sizes of voids are generated between the crystal lattice, resulting in a huge surface area. Therefore, the carbon water contact surface is large and the adsorption capacity is strong. Effectively ensuring the service life of subsequent equipment and improving the quality of effluent water. In the process of pure water production, the role of activated carbon is mainly manifested in four aspects: reducing the oxidation degree of water; Remove residual chlorine from water; Remove trihalides (THM) from water.
3)precision filter
The precision filter is equipped with multiple polypropylene melt blown filter cartridges, which should be replaced when the pressure difference reaches 1kg/cm2. Under normal working conditions, the filter element can maintain a service life of 3 to 6 months or more, and the structure of the filter meets the requirements for quick replacement of the filter element.
4)Slow-release sterilizer
The slow-release sterilizer adopts a chemical reaction, automatic slow-release delayed pressure chlorination process, using strong chlorine solid agents with a content of over 90% as the main raw material. The disinfectant produced by reasonable mixing of water and agents is added to water tanks, wells, pipelines, and sewage tanks for sterilization.

Liaoning Liaoyang wall mounted slow-release disinfectant for outpatient use