Shanghai Yifeng Precision Instrument Co., Ltd
B108, No. 352 Outer Ring Road, Minhang District, Shanghai (201199)
readout system
Ultra high speed digital collector,1 million times per second, using multiple segmented integration method and single spark signal acquisition.
16 bit A/D converter, capable of high-speed sampling at 100kHz per second to ensure acquisition accuracy.
Pre digital control, standard industrialUSB interface. Very convenient to connect with standard computers.
Read system accuracy:RSD≤0.01%
Equipped with fault diagnosis functions for various parts of the instrument, and fully connected in ChineseWindows analysis software can automatically complete fault diagnosis.
detectorAdopting JapanHamamatsu photomultiplier tube
optical system
BaxingDragon grid method, independent suspension vacuum system with grating focal length of 750mm.
Wavelength range:λ150nm-800nm
GermanyZeiss grating engraving line: 2400g/mm focal length: 750mm dazzling wavelength: 190nm
base channel10 of them. (Up to 64 channels)
Photomultiplier tube high voltage1000V stability 0.01% (load variation 100%)
Special processing techniques10um -70um independently adjustable shooting slit. The accuracy is very precise.
sample stage
The size of the spark table is110 X 75mm
The discharge chamber is specially designed to facilitate excitation and save argon gas.
Enclosed spark chamber design to avoid injury to personnel caused by spark radiation.
The excitation electrode is a tungsten electrode or a silver electrode.
analyzesoftware
All in ChineseRun analysis software on Windows, set analysis spark parameters, select excitation, flushing, and pre ignition explosion time, and automatically complete
Automatic data collection. The least squares principle automatically fits the working curve.
Automatic two-point or single point standardization of analysis curves
Automatic sample control calibration, one analysis curve, can choose multi-point sample control calibration.
Output methods available: intensity, intensity ratio, concentration, correction concentration
At the same point, it is possible to repeat one or more excitations, and delete the results of one or more excitations
Automatically calculate the average value,SD and RSD
Correction of interference between elements and background correction
Common standard substance library
The test results can be printed out and saved in a disk. The printing format can be arranged by oneself. It can also be generatedWord documents, etc. Save it.
The test results can be transmitted over long distances through networks and computer standard ports.
The software comes with fault diagnosis and self-test programs. The automatically generated data file can be used to remotely diagnose instrument malfunctions.