The Sensidyne laser dust analyzer is a real-time dust monitoring device that uses mature laser refraction technology to accurately measure dust concentration. This portable monitoring device accurately measures and records dust concentrations ranging from 1-10000 μ g/m3, with a resolution of up to 1 μ g/m3. The sampling mode allows users to choose between 60 second sampling, 15 minute S sampling, or continuous sampling.
This laser dust analyzer is equipped with a built-in air pump to extract air into the ISO Kinitic sample inlet. The air sample is blocked and guided through the particle sensor. This sensor is a photodetector that measures the laser refracted by particles in the air sample. This instrument has a K-parameter that can be set as needed to multiply the original measurement value and display it in real-time on the screen.

The K parameters and environmental parameters set for each sampling, as well as S, maximum, minimum, and average readings, are recorded in the internal data storage. When connected to a computer, the monitor can transmit 4000 recorded data in spreadsheet format.
In addition to high sensitivity and ease of use, Sensidyne provides users with low operating costs, automatic power saving, *, data storage, convenient monitoring functions, and user replaceable filters.
★Accurately measure dust concentration
*The calculation method provides accurate dust concentration, has air barrier function, can avoid internal pollution and improve accuracy.
★Reliable and durable
Equipped with temperature compensation, sturdy casing, and minimal transfer components to ensure measurement reliability.
★Easy to carry
All centralized handheld instruments come with * batteries, which require less than 3 hours to charge.
★Convenient monitoring
Easy to operate software programming for specific environmental conditions and recording sampling data.
★Common applications
Industrial hygiene/occupational hygiene, regional research
Research on particulate matter
Quick fixed-point measurement
Research and investigation on aerogels
Technical Specifications
Measurement method: laser refraction
Sampling method: Inhale air sample by pump
Range: 0.1-10000 μ g/m3
Sampling options: 1-minute, continuous, or 15 minute S
Resolution: 1 μ g/m3
Data recording: 4000 records for S, maximum, minimum, average read values, and K-parameters
Environmental temperature: Operating from 0 ℃ to 50 ℃
Storage -20 ℃ to 60 ℃
Display: 2-line, 16 word LCD
Size: 9.5 x 17.2 x 5.1 cm
Weight: 0.67 kilograms
Power supply: 7.2V rechargeable lithium battery,
Charging time less than 3 hours
Transmission: USB mini B type
Safety certification: FDA/CDRH, CE