LK-8201 Wire and Cable Bending Tester

NegotiableUpdate on 01/31
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
LK-8201 Wire and Cable Bending Tester
Product Details

Product Introduction

satisfyGB5023.2GB5013.2IEC60227-2IEC60245-2UL1581VDE0472HD22.1Waiting for standards

Take the test piece approximately5mWrap the middle section around two circular wheels of the specified diameter, apply a load to both ends of the specimen, and connect the current. Then0.33m/sThe speed,

1mMove the circular wheel to make the specimen bend and stretch back and forth. When the wire breaks or reaches the set number of times, it will automatically stop and the test piece will be removed to evaluate its resistance to bending

Scratching characteristics.

loadLoad

1 / 1.5 / 2 kg ×every4individual

Test CurrentTesting current

AC 220V / 1.035AAC 380C / 3.035A

testing voltageTesting voltage

1∮, AC 220V,60Hz or 3∮,AC 380V,60Hz

Flexible pulleywheel

Φ60 / 80 / 120 / 160 / 200 mmOne set each

Bending strokespce

1000 ± 20mm

Bending speedspeed

0.33 ± 0.05 m/s (constant speed)

counterCounter

Electronic,6Number of digits, reaching the set number of times, automatic shutdown

volumeDimension(W×D×H)

188×53×150cm

weightWeight

250kg

power supplyPower

1∮, AC220V,35A

state

Result judgment

report

guard against

ACore lampBCore lampCThe voltage light of the core lamp is on, and the machine is stopped.

The number of times has reached the set limit.

Do not stop the machine.

There may be a phenomenon of current overload (>30A),

Observe the current values and make corresponding adjustments.

The number of times has not reached, butABCThe light on the chip has turned off and the machine has stopped.

Perhaps a certain core has been broken, indicating an open circuit phenomenon.

The number of times has not reached, but the voltage indicator light is off and the machine is stopped.

The core wire may have short circuited.

Explanation: Other specifications of weights and pulleys can be customized.