LI-830/850 can meet your various measurement needs: (1) self-made assimilation chamber for measuring carbon dioxide and water vapor concentrations, used to evaluate ecosystem carbon exchange and evapotranspiration; (2) Monitor the concentration of carbon dioxide and water vapor in the growth chamber or greenhouse as the basis for controlling their concentration; (3) Atmospheric CO2And H2Continuous positioning monitoring of O concentration. |
![]() |
Application field
|
|
|
Main Features
Easy to operate, plug and play |
![]() ![]()
|
Optional models
| configuration | Detecting CO2And H2O | Detecting CO2 |
| Including built-in pump and display screen | LI-850 | LI-830 |
| Including built-in pump, without display screen | LI-850-1 | LI-830-1 |
| Including display screen, excluding built-in pump | LI-850-2 | LI-830-2 |
| Only analyzer, excluding built-in pump and display screen | LI-850-3 | LI-830-3 |

Technical Specifications
|
CO2measurement Range: 0~20000 μ mol/mol Accuracy: better than 3% of the reading value (LI-830); Better than 1.5% of the reading value (LI-850) Calibration drift Zero drift (℃)-1)1:<0.15 μmol/mol Span drift (℃)-1)2:<0.03 % Total drift (℃)-1)3: <0.4 μmol/mol @ 370 μmol/mol RMS噪声: <1 μmol/mol @ 370 μmol/mol Sensitivity to water vapor (LI-850 only): <0.1 μmol/mol CO2 / mmol/mol H2O Detection limit: 1.5 μ mol/mol H2OMeasurement (LI-850 only) Range: 0-60 mmol/mol Accuracy: better than 1.5% of the reading value Calibration drift Zero drift (℃)-1): <0.003 mmol/mol @ 0 mmol/mol Span drift (℃)-1): <0.03% mmol/mol @ 10 mmol/mol Total drift (℃)-1): <0.009 mmol/mol @ 10 mmol/mol RMS noise: 1-second signal average <0.01 mmol/mol @ 10 mmol/mol Regarding CO2Sensitivity: <0.0001 mmol/mol H2O / μmol/mol CO2 Pump (optional) Typical flow rate: 0.5 L/min Power: 0.75 W |
Display screen (optional) Size: 6.7 cm (diagonal) Resolution: 400 × 200 pixels monochrome Power consumption:<200 μ W Displayed variable: CO2Read value, H2O-reading value (LI-850 only), optical path temperature and air pressure Conventional technical parameters Output frequency: 2 Hz Response time (T90) CO2:<3.5s @ 0-375 μmol/mol; H2O:<3.5s @ 0-21 mmol/mol Measurement principle: Non dispersive infrared Traceability: CO20-3000 μ mol/mol traceable gas calibration using WMO standards, 3000-20000 μ mol/mol traceable gas calibration using EPA protocol standards H2O (LI-850 only): Calibration using LI-610 portable dew point generator, NIST traceable Pressure compensation range: 50-110 kPa Zui atmospheric flow velocity: 1 L/min Output signal: Dual analog voltage (0-2.5 V or 0-5 V) and dual current (4-20mA) Digital output: TTL (0-5V) DAC resolution: 16 bits within user range Power supply demand: Input voltage: 12-30 VDC After preheating: average 0.3A@12 VDC(3.6W) During preheating: average 1.2A@12 VDC(3.6W) Operating temperature range: -20~45 ℃ Relative humidity range: 0-95% RH, non condensing Size: 22.23 × 15.25 × 7.62 cm (8.75 "× 6" × 3 ") Mass: 1 kg Internal optical path volume: 14.5 mL |
| 1Zero drift refers to the variation of measured values with temperature when the gas concentration is 0. 2Span drift refers to the residual after resetting to zero as the temperature changes. 3Total drift refers to the variation of readings with temperature without recalibration |
![]() |
![]() |