LD series electromagnetic flowmeter

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product features: The measurement principle of Shanghai Xuanxu LD series electromagnetic flowmeter is Faraday's law of electromagnetic induction. The main components of the sensor are: measuring tube, electrode, excitation coil, iron core and magnetic yoke housing

Product Details

Product features: The measurement principle of the Shanghai Xuanxu LD series electromagnetic flowmeter is Faraday's law of electromagnetic induction. The main components of the sensor are the measuring tube, electrode, excitation coil, iron core, and magnetic yoke housing. It is mainly used to measure the volumetric flow rate of conductive liquids and slurries in closed pipelines.

Detailed information on LD series electromagnetic flowmeter:

Shanghai Xuanxu LD series electromagnetic flowmeter

summary:

LDThe measurement principle of the series electromagnetic flowmeter is Faraday's law of electromagnetic induction. The main components of the sensor are the measuring tube, electrode, excitation coil, iron core, and magnetic yoke housing. It is mainly used to measure the volumetric flow rate of conductive liquids and slurries in closed pipelines. Including highly corrosive liquids such as acids, alkalis, salts, etc. This product is widely used in industries such as petroleum, chemical, metallurgical, textile, food, pharmaceutical, papermaking, as well as in municipal management, water conservancy construction, and other fields.

Product Features:
1. Measurement is not affected by changes in fluid density, viscosity, temperature, pressure, and conductivity;
2. Measure the flow components inside the tube, with no pressure loss and low requirements for straight pipe sections;
3. Series nominal diameter DN15~DN3000. There are multiple options for sensor lining and electrode materials;
4. The converter adopts a novel excitation method, with low power consumption, low point stability, and high accuracy. The flow range can reach 1500:1;
5. The converter can be integrated or separated from the sensor;
6. The converter adopts a 16 bit high-performance microprocessor, 2x16 LCD display, convenient parameter setting, and reliable programming;
7. The flowmeter is a bidirectional measurement system equipped with three integrators: forward total, reverse total, and differential total; Can display. Zhuang, reverse flow, and have multiple outputs: electric
Flow, pulse, digital communication HART;
8. The converter adopts surface mount technology (SMT) and has self checking and self diagnostic functions;

Main technical data:
Technical data of the whole machine and sensors

execution standard

JB/T 9248—1999

Nominal Diameter

15、 20. 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000

High flow velocity

15m/s

accuracy

DNl5~DN600

Indication: ± 0.3% (flow rate ≥ 1m/s); ± 3mm/s (flow rate<1m/s)

DN700—DN3000

± 0.5% of the indicated value (flow rate ≥ 0.8m/S); ± 4mm/s (flow rate<0.8m/S)

Fluid conductivity

≥5uS/cm

Nominal Pressure

4.0MPa

1.6MPa

1.0MPa

0.6MPa

6.3、10MPa

DNl5~DN150

DNl5~DN600

DN200~DN1000

DN700~DN3000

special order

ambient temperature

sensor

—25℃—60 ℃

Converter and integrated model

—10℃—60 ℃

Lining material

Polytetrafluoroethylene, chloroprene rubber, polyurethane, perfluoroalkoxy (F46), mesh PFA

Very high fluid temperature

body type

70℃

separated type

Polychloroprene rubber lining

80℃120 ℃ (specify when ordering)

Polyurethane lining

80℃

PTFE lining

100℃150 ℃ (specify when ordering)

Perfluoroethylene propylene (F46)

Mesh PFA

Signal electrode and ground electrode materials

Stainless steel 0Crl8Nil2M02Ti, Hastelloy C, Hastelloy B, titanium, tantalum, platinum/iridium alloy, stainless steel coated with tungsten carbide

Electrode scraper mechanism

DN300—DN3000

Connecting flange material

carbon steel

Grounding flange material

Stainless steel 1Cr18Ni9Ti

Imported protective flange materials

DN65—DNl50

Stainless steel 1Cr18Ni9Ti

DN200~DNl600

Carbon steel and stainless steel 1Cr18Ni9Ti

Shell protection

DNl5DN3000 separable rubber or polyurethane lined sensor

IP65Or IP68

Other sensors, body type flow meters, and separate converters

IP65

Distance (separated type)

The distance between the converter and the sensor is generally not more than 100m

Converter technology data

power supply

communication

85—265V,45—400Hz

direct current

11—40V

Operation keys and display

push-button

Four thin film buttons can be used to set and select all parameters, and the converter can also be programmed using a PC (RS232); 3-line LCD with wide viewing angle, wide temperature, and backlit display; The first line displays the traffic value; The second line displays the flow unit; The third line displays the percentage of traffic, total forward, total reverse, total difference, alarm, and flow rate.

Magnetic key type

Two magnetic keys are used for selecting and resetting display parameters, and the converter is programmed using a PC (RS232); 2-line LCD display with wide viewing angle, wide temperature, and backlight: Line 1: Magnetic key selection: Display flow percentage, forward total amount, reverse total amount, difference total amount, alarm, and flow rate. Line 2: Display traffic.

Internal integrator

Positive total, negative total, and differential total.

output signal

Unidirectional analog output

Fully isolated, load ≤ 600D. (at 20mA); Upper limit: 0-21mA optional, 1mA per level; Lower limit: 0-21mA optional, 1mA per level; programming for forward and reverse flow output modes.

Bidirectional analog output

The lower limit is. Or 4mA, other same unidirectional analog outputs.

Bidirectional pulse output

Two outputs correspond to forward and reverse flow rates, with a frequency range of 0-800Hz and an upper limit of 1-800Hz to choose from. Each IHz level is available; Square wave or selected pulse width, with an upper limit of 2.5S and 1ms per step; passive isolation transistor switch output, capable of absorbing 250mA current and withstanding 35V voltage.

Dual channel alarm output

Programmable alarm for high/low flow rate, air traffic control, fault status, positive/negative flow rate, analog over range, pulse over range, pulse small signal cutoff, with optional output polarity; Transistor switch output with isolation protection, capable of absorbing 250mA current and withstanding 35V voltage (not isolated from pulse output)

Digital Communication


RS232,RS485,HART

Selection of lining

Lining material

Main performance

High medium temperature

Scope of Application

body type

separated type


Polytetrafluoroethylene (F4)

It is a chemically stable plastic that can withstand boiling hydrochloric acid, sulfuric acid, nitric acid, and aqua regia, as well as concentrated alkali and various organic solvents. Corrosion caused by intolerance, high temperature, high flow rate liquid fluorine, liquid oxygen, and self oxygen.

70℃

100℃ 150℃ (Special order required)

1Strong corrosive media such as concentrated acid and alkali. 2. Sanitary media.

Perfluoroethylene propylene (F46)

Same as F4, its wear resistance and negative pressure resistance are higher than F4.

Ditto.


Polyfluoroethylene (Fs)

The upper limit of applicable temperature is lower than that of polytetrafluoroethylene, but the cost is also lower.

80℃


Polychloroprene rubber

1Some have elasticity, high tensile strength, and good wear resistance. 2. Resistant to corrosion in general low concentration acid, alkali, and salt media, but not resistant to corrosion in oxidizing media.

80℃ 120℃ (Special order required)

Water, sewage, and weakly abrasive slurry.

polyurethane rubber

1Wear resistance performance.

2Poor corrosion resistance.

80℃

Neutral strong abrasion slurry, coal slurry, mud

Selection of imported protective flanges and grounding flanges (or grounding rings)

Type of flange

Scope of application

Grounding flange (or grounding ring)

Suitable for non-conductive pipelines such as plastic pipes, but sensors with grounding electrodes do not require them.

Import protection flange

Choose when the medium has strong wear resistance.

Selection of electrodes

electrode material

Corrosion resistance and wear resistance

Stainless steel 0Crl8Nil2M02Ti

Used for weakly corrosive media such as industrial water, domestic water, and sewage, suitable for industrial sectors such as petroleum, chemical, and steel, as well as municipal and other fields.

哈氏合金B

It has good corrosion resistance to all concentrations of hydrochloric acid below boiling point, as well as to non chlorinated acids, bases, and non oxidizing salt solutions such as sulfuric acid, phosphoric acid, hydrofluoric acid, and organic acids.

Hastelloy C

Can withstand corrosion from non oxidizing acids such as nitric acid, mixed acids, or mixed media of chromic acid and sulfuric acid, as well as corrosion from oxidizing salts such as Fe, ', Cu', or other oxidants such as hypochlorite solutions above room temperature and seawater

Titanium

Capable of withstanding corrosion from seawater, various chlorides and hypochlorites, oxidizing acids (including fuming sulfuric acid), organic acids, and alkalis. Not resistant to the corrosion of relatively pure reducing acids (such as sulfuric acid, hydrochloric acid), but if the acid contains oxidants (such as nitric acid, Fc++, Cu++), the corrosion is greatly reduced.

Tantalum

It has excellent corrosion resistance and is very similar to glass. Except for hydrofluoric acid, fuming sulfuric acid, and alkali, it can almost withstand corrosion from cutting chemical media (including boiling point hydrochloric acid, nitric acid, and sulfuric acid below 50 ℃). Dig in alkali; Corrosion resistance.

Platinum/titanium alloy

Almost capable of cutting chemical media, but not suitable for aqua regia and ammonium salts.

Stainless steel coated with tungsten carbide

Used for non corrosive and highly abrasive media.

Note: Due to the wide variety of media and the complex factors such as temperature, concentration, and flow rate that affect their corrosiveness, this table is for reference only. Users should make their own choices based on the actual situation, and if necessary, conduct corrosion resistance tests on the selected materials, such as hanging plate tests.

Selection of LD series electromagnetic flowmeter instruments

◆ Range confirmation

Generally, the flow rate of the measured medium in industrial electromagnetic flow meters should be between 2-4m/s. In special cases, the flow rate should not be less than 0.2m/s for very low flow rates and not more than 8m/s for very high flow rates. If the medium contains solid particles, the commonly used flow rate should be less than 3m/s to prevent excessive friction between the lining and the electrode; For viscous fluids, the flow velocity can be chosen to be greater than 2m/s. A higher flow velocity helps to automatically eliminate the effect of viscous substances attached to the electrode, which is beneficial for improving measurement accuracy.

Under the condition that the range Q has been determined, the size of the flowmeter diameter D can be determined based on the range of flow velocity V mentioned above, and its value can be calculated by the following formula:

Q=πD2V/4
Q: Flow rate (㎡/h) D: Inner diameter of pipeline V: Flow rate (m/h)

The range Q of the electromagnetic flowmeter should be greater than the expected large flow value, while the normal flow value should be slightly greater than 50 of the flowmeter's full range scale.

◆ LD electromagnetic flowmeter reference flow range

Caliber mm

Flow range m3/h

Caliber mm

Flow range m3/h

φ15

0.06~6.36

φ450

57.23~5722.65

φ20

0.11~11.3

φ500

70.65~7065.00

φ25

0.18~17.66

φ600

101.74~10173.6

φ40

0.45~45.22

φ700

138.47~13847.4

φ50

0.71~70.65

φ800

180.86~18086.4

φ65

1.19~119.4

φ900

228.91~22890.6

φ80

1.81~180.86

φ1000

406.94~40694.4

φ100

2.83~282.60

φ1200

553.90~55389.6

φ150

6.36~635.85

φ1600

723.46~72345.6

φ200

11.3~1130.4

φ1800

915.62~91562.4

φ250

17.66~176.25.

φ2000

1130.4~113040.00

φ300

25.43~2543.40

φ2200

1367.78~136778.4

φ350

34.62~3461.85

φ2400

1627.78~162777.6

φ400

45.22~4521.6

φ2600

1910.38~191037.6

Selection spectrum of LDE series intelligent electromagnetic flowmeter

model

caliber


LD

15~2600



code name

Installation type


Y

integrated

F

split-type


code name

Converter model

ZA

rotundity

ZB

square


code name

output signal

I.4

4~20mA

f

Frequency 1KHz

Rs

Serial communication (485)

C

controlled output


code name

Explosion-proof requirements

N

No explosion-proof

EX

Explosion proof (only applicable to split type)


code name

medium temperature

T1

≤65℃

T2

≤65℃

T3

≤180℃(Only applicable to split type)


code name

Lining material

NE

Chloroprene rubber (≤ 65 ℃)

PTFE

Polytetrafluoroethylene (≤ 189 ℃)

PVC

Polyvinyl chloride (≤ 70 ℃)


code name

electrode material

316L

stainless steel

HC

Hastelloy C

HB

哈氏合金B

Ti

Titanium

Ta

Tantalum