No. 84 Anyuan Road, Putuo District, Shanghai

Product features: The measurement principle of the Shanghai Xuanxu LD series electromagnetic flowmeter is Faraday's law of electromagnetic induction. The main components of the sensor are the measuring tube, electrode, excitation coil, iron core, and magnetic yoke housing. It is mainly used to measure the volumetric flow rate of conductive liquids and slurries in closed pipelines.
Detailed information on LD series electromagnetic flowmeter:
|
Shanghai Xuanxu LD series electromagnetic flowmeter summary: LDThe measurement principle of the series electromagnetic flowmeter is Faraday's law of electromagnetic induction. The main components of the sensor are the measuring tube, electrode, excitation coil, iron core, and magnetic yoke housing. It is mainly used to measure the volumetric flow rate of conductive liquids and slurries in closed pipelines. Including highly corrosive liquids such as acids, alkalis, salts, etc. This product is widely used in industries such as petroleum, chemical, metallurgical, textile, food, pharmaceutical, papermaking, as well as in municipal management, water conservancy construction, and other fields. |
Product Features: |
Main technical data:
Technical data of the whole machine and sensors
execution standard |
JB/T 9248—1999 |
||||
Nominal Diameter |
15、 20. 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000 |
||||
High flow velocity |
15m/s |
||||
accuracy |
DNl5~DN600 |
Indication: ± 0.3% (flow rate ≥ 1m/s); ± 3mm/s (flow rate<1m/s) |
|||
DN700—DN3000 |
± 0.5% of the indicated value (flow rate ≥ 0.8m/S); ± 4mm/s (flow rate<0.8m/S) |
||||
Fluid conductivity |
≥5uS/cm |
||||
Nominal Pressure |
4.0MPa |
1.6MPa |
1.0MPa |
0.6MPa |
6.3、10MPa |
DNl5~DN150 |
DNl5~DN600 |
DN200~DN1000 |
DN700~DN3000 |
special order |
|
ambient temperature |
sensor |
—25℃—60 ℃ |
|||
Converter and integrated model |
—10℃—60 ℃ |
||||
Lining material |
Polytetrafluoroethylene, chloroprene rubber, polyurethane, perfluoroalkoxy (F46), mesh PFA |
||||
Very high fluid temperature |
—body type |
70℃ |
|||
separated type |
Polychloroprene rubber lining |
80℃120 ℃ (specify when ordering) |
|||
Polyurethane lining |
80℃ |
||||
PTFE lining |
100℃150 ℃ (specify when ordering) |
||||
Perfluoroethylene propylene (F46) | |||||
Mesh PFA | |||||
Signal electrode and ground electrode materials |
Stainless steel 0Crl8Nil2M02Ti, Hastelloy C, Hastelloy B, titanium, tantalum, platinum/iridium alloy, stainless steel coated with tungsten carbide |
||||
Electrode scraper mechanism |
DN300—DN3000 |
||||
Connecting flange material |
carbon steel |
||||
Grounding flange material |
Stainless steel 1Cr18Ni9Ti |
||||
Imported protective flange materials |
DN65—DNl50 |
Stainless steel 1Cr18Ni9Ti |
|||
DN200~DNl600 |
Carbon steel and stainless steel 1Cr18Ni9Ti |
||||
Shell protection |
DNl5DN3000 separable rubber or polyurethane lined sensor |
IP65Or IP68 |
|||
Other sensors, body type flow meters, and separate converters |
IP65 |
||||
Distance (separated type) |
The distance between the converter and the sensor is generally not more than 100m |
||||
Converter technology data
power supply |
communication |
85—265V,45—400Hz |
direct current |
11—40V |
|
Operation keys and display |
push-button |
Four thin film buttons can be used to set and select all parameters, and the converter can also be programmed using a PC (RS232); 3-line LCD with wide viewing angle, wide temperature, and backlit display; The first line displays the traffic value; The second line displays the flow unit; The third line displays the percentage of traffic, total forward, total reverse, total difference, alarm, and flow rate.
|
Magnetic key type |
Two magnetic keys are used for selecting and resetting display parameters, and the converter is programmed using a PC (RS232); 2-line LCD display with wide viewing angle, wide temperature, and backlight: Line 1: Magnetic key selection: Display flow percentage, forward total amount, reverse total amount, difference total amount, alarm, and flow rate. Line 2: Display traffic.
|
|
Internal integrator |
Positive total, negative total, and differential total. |
|
output signal |
Unidirectional analog output |
Fully isolated, load ≤ 600D. (at 20mA); Upper limit: 0-21mA optional, 1mA per level; Lower limit: 0-21mA optional, 1mA per level; programming for forward and reverse flow output modes.
|
Bidirectional analog output |
The lower limit is. Or 4mA, other same unidirectional analog outputs. |
|
Bidirectional pulse output |
Two outputs correspond to forward and reverse flow rates, with a frequency range of 0-800Hz and an upper limit of 1-800Hz to choose from. Each IHz level is available; Square wave or selected pulse width, with an upper limit of 2.5S and 1ms per step; passive isolation transistor switch output, capable of absorbing 250mA current and withstanding 35V voltage.
|
|
Dual channel alarm output |
Programmable alarm for high/low flow rate, air traffic control, fault status, positive/negative flow rate, analog over range, pulse over range, pulse small signal cutoff, with optional output polarity; Transistor switch output with isolation protection, capable of absorbing 250mA current and withstanding 35V voltage (not isolated from pulse output)
|
|
Digital Communication |
RS232,RS485,HART |
|
Selection of lining
Lining material |
Main performance |
High medium temperature |
Scope of Application |
|
—body type |
separated type |
|||
Polytetrafluoroethylene (F4) |
It is a chemically stable plastic that can withstand boiling hydrochloric acid, sulfuric acid, nitric acid, and aqua regia, as well as concentrated alkali and various organic solvents. Corrosion caused by intolerance, high temperature, high flow rate liquid fluorine, liquid oxygen, and self oxygen. |
70℃ |
100℃ 150℃ (Special order required) |
1Strong corrosive media such as concentrated acid and alkali. 2. Sanitary media. |
Perfluoroethylene propylene (F46) |
Same as F4, its wear resistance and negative pressure resistance are higher than F4. |
Ditto. |
||
Polyfluoroethylene (Fs) |
The upper limit of applicable temperature is lower than that of polytetrafluoroethylene, but the cost is also lower. |
80℃ |
||
Polychloroprene rubber |
1Some have elasticity, high tensile strength, and good wear resistance. 2. Resistant to corrosion in general low concentration acid, alkali, and salt media, but not resistant to corrosion in oxidizing media. |
80℃ 120℃ (Special order required) |
Water, sewage, and weakly abrasive slurry. |
|
polyurethane rubber |
1Wear resistance performance. 2Poor corrosion resistance. |
80℃ |
Neutral strong abrasion slurry, coal slurry, mud |
|
Selection of imported protective flanges and grounding flanges (or grounding rings)
Type of flange |
Scope of application |
Grounding flange (or grounding ring) |
Suitable for non-conductive pipelines such as plastic pipes, but sensors with grounding electrodes do not require them. |
Import protection flange |
Choose when the medium has strong wear resistance. |
Selection of electrodes
electrode material |
Corrosion resistance and wear resistance |
Stainless steel 0Crl8Nil2M02Ti |
Used for weakly corrosive media such as industrial water, domestic water, and sewage, suitable for industrial sectors such as petroleum, chemical, and steel, as well as municipal and other fields. |
哈氏合金B |
It has good corrosion resistance to all concentrations of hydrochloric acid below boiling point, as well as to non chlorinated acids, bases, and non oxidizing salt solutions such as sulfuric acid, phosphoric acid, hydrofluoric acid, and organic acids. |
Hastelloy C |
Can withstand corrosion from non oxidizing acids such as nitric acid, mixed acids, or mixed media of chromic acid and sulfuric acid, as well as corrosion from oxidizing salts such as Fe, ', Cu', or other oxidants such as hypochlorite solutions above room temperature and seawater |
Titanium |
Capable of withstanding corrosion from seawater, various chlorides and hypochlorites, oxidizing acids (including fuming sulfuric acid), organic acids, and alkalis. Not resistant to the corrosion of relatively pure reducing acids (such as sulfuric acid, hydrochloric acid), but if the acid contains oxidants (such as nitric acid, Fc++, Cu++), the corrosion is greatly reduced. |
Tantalum |
It has excellent corrosion resistance and is very similar to glass. Except for hydrofluoric acid, fuming sulfuric acid, and alkali, it can almost withstand corrosion from cutting chemical media (including boiling point hydrochloric acid, nitric acid, and sulfuric acid below 50 ℃). Dig in alkali; Corrosion resistance. |
Platinum/titanium alloy |
Almost capable of cutting chemical media, but not suitable for aqua regia and ammonium salts. |
Stainless steel coated with tungsten carbide |
Used for non corrosive and highly abrasive media. |
Note: Due to the wide variety of media and the complex factors such as temperature, concentration, and flow rate that affect their corrosiveness, this table is for reference only. Users should make their own choices based on the actual situation, and if necessary, conduct corrosion resistance tests on the selected materials, such as hanging plate tests. | |
Selection of LD series electromagnetic flowmeter instruments
◆ Range confirmation
Generally, the flow rate of the measured medium in industrial electromagnetic flow meters should be between 2-4m/s. In special cases, the flow rate should not be less than 0.2m/s for very low flow rates and not more than 8m/s for very high flow rates. If the medium contains solid particles, the commonly used flow rate should be less than 3m/s to prevent excessive friction between the lining and the electrode; For viscous fluids, the flow velocity can be chosen to be greater than 2m/s. A higher flow velocity helps to automatically eliminate the effect of viscous substances attached to the electrode, which is beneficial for improving measurement accuracy.
Under the condition that the range Q has been determined, the size of the flowmeter diameter D can be determined based on the range of flow velocity V mentioned above, and its value can be calculated by the following formula:
Q=πD2V/4
Q: Flow rate (㎡/h) D: Inner diameter of pipeline V: Flow rate (m/h)
The range Q of the electromagnetic flowmeter should be greater than the expected large flow value, while the normal flow value should be slightly greater than 50 of the flowmeter's full range scale.
◆ LD electromagnetic flowmeter reference flow range
Caliber mm |
Flow range m3/h |
Caliber mm |
Flow range m3/h |
φ15 |
0.06~6.36 |
φ450 |
57.23~5722.65 |
φ20 |
0.11~11.3 |
φ500 |
70.65~7065.00 |
φ25 |
0.18~17.66 |
φ600 |
101.74~10173.6 |
φ40 |
0.45~45.22 |
φ700 |
138.47~13847.4 |
φ50 |
0.71~70.65 |
φ800 |
180.86~18086.4 |
φ65 |
1.19~119.4 |
φ900 |
228.91~22890.6 |
φ80 |
1.81~180.86 |
φ1000 |
406.94~40694.4 |
φ100 |
2.83~282.60 |
φ1200 |
553.90~55389.6 |
φ150 |
6.36~635.85 |
φ1600 |
723.46~72345.6 |
φ200 |
11.3~1130.4 |
φ1800 |
915.62~91562.4 |
φ250 |
17.66~176.25. |
φ2000 |
1130.4~113040.00 |
φ300 |
25.43~2543.40 |
φ2200 |
1367.78~136778.4 |
φ350 |
34.62~3461.85 |
φ2400 |
1627.78~162777.6 |
φ400 |
45.22~4521.6 |
φ2600 |
1910.38~191037.6 |
Selection spectrum of LDE series intelligent electromagnetic flowmeter
model |
caliber |
||||||||
LD |
15~2600 |
||||||||
code name |
Installation type |
||||||||
Y |
integrated |
||||||||
F |
split-type |
||||||||
code name |
Converter model |
||||||||
ZA |
rotundity |
||||||||
ZB |
square |
||||||||
code name |
output signal |
||||||||
I.4 |
4~20mA |
||||||||
f |
Frequency 1KHz |
||||||||
Rs |
Serial communication (485) |
||||||||
C |
controlled output |
||||||||
code name |
Explosion-proof requirements |
||||||||
N |
No explosion-proof |
||||||||
EX |
Explosion proof (only applicable to split type) |
||||||||
code name |
medium temperature |
||||||||
T1 |
≤65℃ |
||||||||
T2 |
≤65℃ |
||||||||
T3 |
≤180℃(Only applicable to split type) |
||||||||
code name |
Lining material |
||||||||
NE |
Chloroprene rubber (≤ 65 ℃) |
||||||||
PTFE |
Polytetrafluoroethylene (≤ 189 ℃) |
||||||||
PVC |
Polyvinyl chloride (≤ 70 ℃) |
||||||||
code name |
electrode material |
||||||||
316L |
stainless steel |
||||||||
HC |
Hastelloy C |
||||||||
HB |
哈氏合金B |
||||||||
Ti |
Titanium |
||||||||
Ta |
Tantalum |
||||||||