Japan * Scientific Chemical Oxygen Demand Tester COD-60A
Easy to operate! The sequence control from oxidation to titration has been automated and greatly improved in operability.
COD-60A "is a
A simple COD measuring instrument that uses a measurement unit integrated with a heating/titration processing unit.
*The control method can automatically execute sequential control from oxidation to titration, thereby
Greatly improved operability.
After collecting a certain amount of samples/reagents into the measuring container, place them in the measuring unit,
Then press the asterisk on the hotkey to automatically print the oxidation titration and control the results.
[Features]
Significant improvement in operability
■ Reduced errors between measuring instruments
The amount of waste liquid is below 10 mL
■ Adopting titration method and achieving fruitful results
■ Multi range, directly read COD value
Japan * Scientific Chemical Oxygen Demand Tester COD-60A
Other functions
■ Sequential state during measurement/titration curve display process, with measuring end buzzer
Conversion of measurement values for display/printing measurement methods
■ Comprehensive maintenance/inspection functions
■ Statistical calculation function
Data storage function (100 pieces of data), built-in printer
*For detailed information, please refer to the PDF document or feel free to contact us at any time.
A simple COD measuring instrument that uses a measurement unit integrated with a heating/titration processing unit.
*The control method can automatically execute sequential control from oxidation to titration, thereby
Greatly improved operability.
After collecting a certain amount of samples/reagents into the measuring container, place them in the measuring unit,
Then press the asterisk on the hotkey to automatically print the oxidation titration and control the results.
[Features]
Significant improvement in operability
■ Reduced errors between measuring instruments
The amount of waste liquid is below 10 mL
■ Adopting titration method and achieving fruitful results
■ Multi range, directly read COD value