Welcome Customer !

Membership

Help

Jiuyin Technology Development (Shanghai) Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Jiuyin Technology Development (Shanghai) Co., Ltd

  • E-mail

    athena@joyn-tech.com

  • Phone

    18221287376

  • Address

    Room 6009-6011, Building 1, Zhongzhen Science and Technology Innovation Park, 3399 Yuanjiang Road, Minhang District, Shanghai

Contact Now

JY-1603 Oxygen Transmitter

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Measurement principle: ion current (limit current) Display mode: 64 × 48 dot matrix OLED Measurement range: 0.1%~21.0% O2 Resolution: 0.1% Measurement accuracy: ≤ 1% FS repeatability: ≤ 1% response time: T90 ≤ 30s Analog output: 4-20mA. DC (non isolated output)

Product Details

Measurement principle: ion current (limiting current)
Display mode: 64 × 48 dot matrix OLED
Measurement range: 0.1%~21.0% O2
Resolution: 0.1%
Measurement accuracy:±1%FS
Repeatability:±1%
Response time: T9030S
Analog output: 4-20mA. DC (non isolated output, load resistance less than 500 ohms)
2-channel programmable dry contact type passive alarm output, contact * * capacity 220VAC/2A
Communication interface: RS485
Sample gas temperature: -10~+50 ℃
Sample gas pressure: 86-106kPa, stable pressure atmosphere
Sample gas temperature: -10~+50 ℃
Sample gas composition: no flammable gas, no corrosive gas, dust content less than 1mg/Nm3
Sampling method: Insertion (diffusion)
Environmental humidity:<80% RH
Power supply: DC24V 1**
Specification size: 110mm × 99mm × 45mm (H × W × D)
Hole size: 96mm × 25mm (H × W)
Connecting cable: 3 meters (standard)
Service life:>3 years (under normal usage conditions)
Installation method: transmitter wall mounted installation, probe insertion installation (KF40)