Introduction to Wi Fi Network Noise Sensor

NegotiableUpdate on 01/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Details

Wireless network noise sensorsound level meterJHM-NS02 is equipped with a Wi Fi module JHM-MFFI.

Technical parameters of network module: IEEE 802.11 standard. Users can define their own IP, port address, access hotspot, password, as well as set the destination IP and port for delivery!


Module Name: JHM-MFWIFI


----------------------------------------------------------------------------------------------------------------------------------------------------

JHM-WIFI module, powered by DC12V, IEEE 802.11 standard. Working in STA mode, IP/UDP communication mode.
The user uses the matching serial communication cable, with serial port baud rates of 9600 and 8 n、 1. The module can be configured using the serial assistant software through the computer serial port,

All command characters are capitalized, and the specific instruction operations are as follows:
a: Sending a HELP? (Enter) Give the module, and the module returns commonly used operation commands to help the operator remember them conveniently.
b: Sending CM+INFO=? (Enter), The module returns all information including the set IP, target IP, port, hotspot name, and password.
c: Sending CM+MYIP=? (Enter), The module returns its own IP address, enter CM+MYIP=IP=192.168.0.1 (Enter), and the module IP is changed to the current IP address.
d: Sending CM+OBIP=? (Enter), The module returns the IP address of the noise transmission target, input CM+OBIP=192.168.0.100 (Enter), the noise data transmission destination

Change the address to the current IP
e: Send CM+PORT=? (Enter), Query local and target port addresses, with port lengths below 5 bits (greater than 4000).
f: Sending CM+HOTA=? (Enter), Search for the name of the access hotspot, enter CM+HOTA=abcdeefg (Enter), abcdeefg wants to access as the hotspot name.
g: Sending CM+PASS=? (Enter), Query and set the access hotspot password, enter CM+PASS=(Enter) as the access hotspot password.

Noise data format: CM+NS02=056.7 (Enter), '=' followed by 3 integers and 1 decimal is the noise value

*************************************************************************************

IEEE 802.11 standard. Define your own IP, port address, access hotspot, password, and destination IP and port settings! 3-channel switch output, capable of driving

Electric fan, humidifier, water pump, lighting, etc. RS232、 485 bus, SPI port, and analog input. Can be connected to external devices for temperature, humidity, noise, wind speed, wind direction, etc,

Cloud expansion.