- Phone
-
Address
185 Haichuan Road, Shanghai
Shanghai Ziyi Automation Instrument Co., Ltd
185 Haichuan Road, Shanghai
| ZY-600 series intelligent digital display instrumentDetailed information: |
|
overview ZY-600The series of intelligent digital instruments adopts high-performance and highly anti-interference integrated instrument chips. The measurement input and transmitter output adopt digital calibration and self calibration technology, which ensures accurate and stable measurement and eliminates measurement errors caused by temperature drift. And throughEMCElectromagnetic compatibility testing has strong anti-interference ability, high reliability, and high cost-effectiveness.
ZY-600The series of instruments have programmable functions for multiple types of inputs, and one instrument can be paired with different input signals (thermocouples)/thermal resistance/Linear voltage/linear current/linear resistance/At the same time, the display range and alarm control can be set by the user on-site, and can be used in conjunction with various sensors and transmitters to achieve measurement, display, adjustment, alarm control, data acquisition, and recording of physical quantities such as temperature, pressure, liquid level, capacity, and force.
Intelligent digital display instrument with dual row or single four digitsLEDDisplay measurement values(PV)And the set value(SV)Analog display of measured value percentages using monochrome or two-color light columns, with zero and full correction, cold end compensation, digital filtering, communication interface, etc6Multiple alarm methods, optional1~4Relay alarm output, optional transmitter output, or standard communication interface(RS485perhapsRS232C)Output, etc.
main features
Intelligent digital display alarm device
1、Specialized electromagnetic devices have more reliable anti-interference and stability.
2、Universal model input, can be matched with commonly used thermal signals through menu settings.
3、The display range, transmission output range, alarm value, and alarm mode can be modified online.
4、Equipped with high-density light column simulation display function.
5、Dual circuit instruments can independently set the type of input signal.
Intelligent hand operator
1、Double row4positionLED、40The dual light column can display control signals and valve position feedback signals simultaneously.
2、The valve position limit amplitude can be set to ensure that the actuator operates safely within the set safe valve position range.
3、Having hands/Automatic disturbance free switching function, widely used in computersDCSAutomatic control systems such as systems and regulators.
4、Equipped with a lock up time setting function, effectively protecting the actuator.
Intelligent traffic integrator
1、The square root function can be implemented in the table, and the instantaneous flow rate can be changed to input.
2、It can achieve upper and lower limit alarm functions for instantaneous flow.
3、It can provide power distribution function for external two - and three wire transmitters.
4、Automatic temperature and pressure compensation, with diverse input signal types.
5、Multiple traffic calculation modes and density compensation methods.
6、It has the function of specifying the large and small traffic of the protocol.
Intelligent inspection device
1、Each channel can independently select various types of thermal signal input.
2、The measurement range and upper and lower limit alarm values for each channel can be set separately.
3、It has fast pathfinding and fixed-point monitoring functions, and the patrol time can be set.
General technical specifications for intelligent digital display instruments
1、measure/Accuracy of transmission system: ±0.2%XF.S
2、Number display: Four digit display, floating point decimal
3、Sampling speed: ≤100ms/order
4、Display resolution: Last digit1One word
5、Temperature drift: ≤100ppm
6、Cold end temperature compensation accuracy: ±1℃(Preheating)30Minutes)
7、Allowable lead resistance when measuring thermal resistance: ≤30Ω
8、Working temperature: Industrial grade standard-10~+55℃
9、Input impedance:electric current:100Ω,voltage:500KΩ
10Output impedance:4-20mAWhen outputting0-550Ω;0-10mAWhen outputting0-1KΩ
11Transmission output ripple:≤50mVp-p
12Alarm relay contact capacity:AC220V,1A; DC24V,2A(Resistive load)
13Communication interface:RS232perhapsRS485
14Communication Protocol:international standardMODBUS-RTUagreement
15Communication distance:RS485:Number of nodes ≤256(When no relay is added),Distance ≤1000rice(Baud rate9600time)
16Distribution output voltage:DC24±1V 50mA,Automatic overcurrent protection
17Insulation strength(input/output/communication/Between power sources):Not less than1500V.ACa minute
18Insulation impedance(power supply/input/output/Communication between):Not less than100MΩ
19Allowable atmospheric pressure during work:80-106kPa
20Allowable relative humidity during work:10-90%RH(40℃time)
21Allowable ambient temperature during storage and transportation:-40~+80℃
22Power supply:exchange:AC220V(Allowable range of variation95~265V)
direct-current:DC24V(Allowable range of variation16~28V)
Environmental conditions for use
The installation location must not have strong mechanical vibration, impact
And high currents and sparks from the signal end, power end, and space
Waiting for the influence of electromagnetic induction,There must be no metal or plastic in the air
Gas that causes corrosion.
Other special parameters
Please refer to the product technical manual for specific parameters of each specification product.
|
| If you are correctZY-600 series intelligent digital display instrumentIf you are interested and would like to learn more detailed product information, please fill out the following form to directly contact the manufacturer: |