| test project |
Insulation resistance (DC voltage application method) |
Test voltage/measurement range (Manual/Automatic) |
25 V ≦ V < 100 V (2.000/20.00/200.0 MΩ), 100 V ≦ V < 500 V (2.000/20.00/200.0/2000 MΩ), 500 V ≦ V ≦ 1000 V (2.000/20.00/200.0/4000/9990 MΩ) |
| Basic Accuracy |
±2 % rdg. ±5 dgt. 25 V ≦ V < 100 V [0~20 MΩ], 100 V ≦ V < 500 V [0~20 MΩ], 500 V ≦ V ≦ 1000 V [0~200 MΩ] |
| test speed |
FAST: 30ms/time, SLOW: 500ms/time (switching) |
| display screen |
LCD (with a lifespan of 100000 hours), 4-stage backlight |
| storage function |
Save contents: rated measurement voltage, upper and lower limits of comparator, test mode, buzzer sound during judgment, test time, response time, resistance range, measurement speed Storage capacity: Up to 10 sets (can be saved/read) |
| test mode |
Continuous mode, PASS STOP mode, FAIL STOP mode, and forced end judgment mode (switching) |
| Compare settings |
UPPER-FAIL: Measurement value ≥ upper limit value PASS: Upper limit value>measured value>lower limit value LOWER-FAIL: Measurement value ≤ lower limit value |
| Judgment processing |
Beep sound, LED lights for PASS/U.FAIL/L.FAIL are on, and the lights for U.FAIL/L.FAIL are on at the same time when UL_LAIL is on. EXT. I/O output, and the judgment result is obtained through RS-232C |
| Test time timer |
0.045 s to 999.999 s (0.001 s resolution), the time from applying voltage to determining whether it is qualified or not |
| Response time timer |
After the experiment begins, it is prohibited to set the comparator to determine the action time between 0.005 s and 999.999 s (0.001 s resolution) |
| analog output |
DC +4 V f.s. |
| interface |
RS-232C (standard), external I/O (input for external controller, output of judgment result), BCD output (* ST5520-01) |
| power supply |
AC100 V ~ 240 V,50/60Hz,zui 大25VA |
| Volume and weight |
215W×80H×166Dmm,1.1kg |
| attachment |