High voltage differential scanning calorimeter DSC

NegotiableUpdate on 02/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

High voltage differential scanning calorimeter DSC204HPPhoenix Instrument Introduction: In practical applications, many physical processes and chemical reactions are affected by gas pressure

Product Details

High pressure differential scanning calorimeter DSC 204 HP Phoenix ®

Instrument Introduction:

In practical applications, many physical processes and chemical reactions are affected by gas pressure. Therefore, it is often necessary to conduct DSC experiments while maintaining a certain pressure.


NETZSCH has developed a high-pressure differential scanning calorimeter DSC 204 HP, which has a sturdy gold-plated measuring cell and can perform experiments under various atmospheres such as O2, N2, Ar, He, H2, CO2, CH4, etc. under high pressure. The pressure range can be from vacuum to 15 MPa (150 bar), and the testing temperature can reach 600 ° C. If equipped with a liquid nitrogen controller CC 200 L, the temperature can reach -150 ° C.


The sample atmosphere can be static or dynamic. The electronic pressure control device and precise blowing airflow regulation ensure the accuracy and repeatability of the experiment. The DSC 204 HP has good safety performance and meets all safety requirements for high-pressure experiments.


The DSC 204 HP is currently a DSC system on the market that operates under high pressure and is capable of measuring negative temperature and high pressure. As a result, the product won the R&D100 award immediately after its launch.

DSC 204 HP - Technical Parameters

  • Wide pressure range: vacuum 15MPa (approximately 2176psi)
  • Accurate pressure regulation (0.002 MPa)
  • Temperature range:
    - -150°C . .. 600°C(1 bar)
    - -90°C . .. 600°C (50 bar)
    - -50°C . .. 450°C (150 bar)
  • Heating rate: 0.01 .. 100 K/min
  • Different measurement atmospheres can be selected:
    -Inert: N2, inert gas
    -Reductive: H2
    -Oxidation: O2, CO2, air
  • Other gas types can be used as needed.
  • Accurate gas flow regulation: 500ml/min
  • Gold plated furnace body, excellent corrosion resistance.
  • Can replace sensors with different performance.