YGDC High and Low Temperature Impact Test Chamber Cold and Hot Impact Test Chamber
Scope of Application:
Suitable for testing in industries such as electronic components, semiconductors, electronic circuit boards, metal materials, etc., it can withstand continuous temperature and extremely low temperature environments in an instant, and can detect various changes caused by thermal expansion and contraction of the sample in the shortest possible time. It is a testing equipment for materials industries such as metal, plastic, rubber, and electronics.
Product Features:
The inner chamber of the test box is made of 304 stainless steel plate, and the outer shell is treated with steel plate spray coating to ensure the long-term anti-corrosion function and appearance life of the equipment. The shape is beautiful and generous, and high-quality handles are used for easy operation.
The test chamber is divided into low temperature zone and high temperature zone. During the impact test, the high temperature zone and low temperature zone are automatically opened to achieve the impact test of high temperature and low temperature.
The test box door, circulating fan, and lifting blue drive are interlocked. Once the box door is opened, the power supply of the circulating fan and lifting blue drive will be automatically cut off to protect the safety of the operator.
The refrigeration system of the high and low temperature impact test chamber adopts an imported fully enclosed compressor to ensure the cooling rate and meet the requirements of the lowest temperature.
The temperature control adopts a programmable color touch screen, with simple and reliable operation and data acquisition. The intuitive graphical curve display function allows the operator to easily observe the experimental process.
safety protectionLeakage, short circuit, overheating, water shortage, motor overheating, compressor overpressure, overload, overcurrent protection.
Technical Specifications:
Model YGDC4050
Studio size 800 × 700 × 900
Impact temperature -40 ℃ -+150 ℃
Temperature fluctuation ≤ ± 0.5 ℃
Temperature uniformity ≤± 2 ℃