E-mail
348933931@qq.com
-
Phone
18017242729
-
Address
Room 310, 4289 Hongmei South Road, Minhang District, Shanghai
Shanghai Hengfang Scientific Instrument Co., Ltd
348933931@qq.com
18017242729
Room 310, 4289 Hongmei South Road, Minhang District, Shanghai
Instrument Introduction:
The HQ40d dual input multi parameter digital analyzer is a plug and play, dual interface display analyzer that can be used with any two IntelliCAL electrodes. An analyzer can measure pH, conductivity, and LDO, and can use two different electrodes to measure simultaneously. The measurement information of both electrodes can be seen on the same display screen, and GLP/ISO data can be transmitted to a USB flash drive or computer - all data records can be transmitted, or individual readings can be transmitted. In addition, HQ40d also has advantages such as saving time and measuring economy.
Technical Indicators:
Please refer to the technical parameters of the electrode for the measurement range
Power supply: 4AA battery; Battery life:>200 hours, including AC/DC power connection
Display: can display readings from 1 or 2 electrodes, and can display readings from both electrodes simultaneously
PH electrode: pH, mV, temperature
Conductivity electrode: selected parameters, temperature correction, and temperature
LDO electrode: dissolved oxygen, pressure, temperature
Data memory: 500 sets of data
Data storage: Calibration data is stored in logs. It can be automatically stored in the "press to read" mode and interval measurement mode. Manual storage is required in the 'continuous reading' mode.
Data transfer: Data can be downloaded to a computer or flash memory using a USB interface. It can automatically transmit data records and also transmit measured readings.
Temperature correction/compensation: three modes, namely off, automatic, and manual (correction should be based on parameters)
Lock display function: Continuous measurement mode or press to read measurement mode has the function of averaging LDO measurement readings.
Automatic recognition of pH buffer: There are three options to choose from:
PH automatic recognition function: can recognize standard solutions with pH values of 4, 7, and 10
IUPAC: 1,679, 4,005, 7,000, 10,012,
DIN: 1.09,4.65,9.23
Waterproof: The measuring instrument casing can be soaked in water up to 1 meter deep for 30 minutes (IP67)
Ordering information:
Only HQ40dMulti parameter digital analyzer:
HQ40d5300000: HQ40d dual channel input, multi parameter digital analyzer
8505200:HQ40DImpact resistant on-site dissolved oxygen analyzer
Configuration includes: HQ40d host, LDO10105 shock resistant dissolved oxygen probe, A/C power adapter, USB adapter, carrying case (with foam filler inside), etc
8505300:HQ40DImpact resistant on-site dissolved oxygen/pH/Conductivity meter
Configuration includes: HQ40d host, LDO10105 impact resistant dissolved oxygen probe, pHC10105 impact resistant pH probe, CDC 40105 impact resistant conductivity probe, A/C power adapter, USB adapter, carrying case (with foam filler inside), etc
8505400:HQ40DImpact resistant on-site dissolved oxygen/pHmeasuring instrument
Configuration includes: HQ40d host, LDO10105 shock resistant dissolved oxygen probe, pHC10105 shock resistant pH probe, A/C power adapter, USB adapter, carrying case (with foam filler inside), etc
8506000:HQ40DStandard on-site dissolved oxygen/pH/Conductivity meter
Configuration includes: HQ40d host, LDO10101 standard dissolved oxygen probe, pHC10101 standard pH probe, CDC 40101 standard conductivity probe, A/C power adapter, USB adapter, carrying case (with foam filler inside), etc
8507300:HQ40Don-siteORPmeasuring instrument
Configuration includes: HQ40d host, MTC10105 impact resistant ORP probe, A/C power adapter, USB adapter, carrying case (with foam filler inside), etc
8507400:HQ40DImpact resistant on-site ORP/Dissolved oxygen analyzer
Configuration includes: HQ40d host, LDO10105 shock resistant dissolved oxygen probe, MTC10105 shock resistant ORP probe, A/C power adapter, USB adapter, carrying case (with foam filler inside), etc
8507500: Impact resistant environmental conductivity/Dissolved oxygen analyzer
Configuration includes: HQ40d host, LDO10105 shock resistant dissolved oxygen probe, CDC 40105 shock resistant conductivity probe, A/C power adapter, USB adapter, carrying case (with foam filler inside), etc
8505500: Carrying case
Sensor for two 5m cables, 4 sample bottles, 500ml rinse bottle
8505501:Carrying case
Sensor for three 5m cables, 4 sample bottles, 500ml rinse bottle
pHelectrode
Ultra liquid filled standard composite electrode: pHC28101 (1 meter), pHC28103 (3 meters)
Gel standard composite electrode: pHC10101 (1m), pHC10103 (3m)
Gel solid composite electrode: pHC10105 (5m), pHC10110 (10m), pHC10115 (15m), pHC10130 (30m)
Liquid filled standard composite electrode: pHC30101 (1 meter), pHC30103 (3 meters)
ORPelectrode
Gel standard composite electrode: MTC10101 (1m), MTC10103 (3m)
Gel solid composite electrode: MTC10105 (5m), MTC10110 (10m), MTC10115 (15m), MTC10130 (30m)
Liquid filled standard composite electrode: MTC30101 (1 meter), MTC30103 (3 meters)
Conductivity electrode
Standard electrodes: CDC40101 (1 meter), CDC40103 (3 meters)
Durable electrodes: CDC40105 (5 meters), CDC40110 (10 meters), CDC40115 (15 meters), CDC40130 (30 meters)
Dissolved oxygen electrode
Standard electrodes: LDO10101 (1 meter), LDO10103 (3 meters)
Durable electrodes: LDO10105 (5 meters), LDO10110 (10 meters), LDO10115 (15 meters), LDO10130 (30 meters)
ISEion selective electrode
Sodium ion selective electrode: ISENa38101 (1 meter), ISENa38103 (3 meters)
Ammonia nitrogen electrode: ISENH318101 (1 meter), ISENH318103 (3 meters), ISENH418101 (1 meter), ISENH418103 (3 meters)
Chloride electrode: ISECl18101 (1 meter), ISECl18103 (3 meters)
Fluoride ion electrode: ISEF12101 (1 meter), ISEF12103 (3 meters)
Nitrate electrode: ISENO318101 (1 meter), ISENO318103 (3 meters)