Phone
18930767719
-
Address
Room 307, Huacheng Plaza, 1471 Gumei Road, Minhang District, Shanghai
Shanghai Shouli Industrial Co., Ltd
18930767719
Room 307, Huacheng Plaza, 1471 Gumei Road, Minhang District, Shanghai
Product Introduction
HORIBA Multi Parameter Water Quality Analyzer
U-50Comparison of Series Functions
U-51 |
U-52 |
U-52G |
U-53 |
U-53G |
|
pH |
○ |
○ |
○ |
○ |
○ |
dissolved oxygen |
○ |
○ |
○ |
○ |
○ |
conductance |
○ |
○ |
○ |
○ |
○ |
salinity |
○ |
○ |
○ |
○ |
○ |
TDS (Total Dissolved Solids) |
○ |
○ |
○ |
○ |
○ |
Specific gravity of seawater |
○ |
○ |
○ |
○ |
○ |
temperature |
○ |
○ |
○ |
○ |
○ |
Turbidity (LED) |
— |
○ |
○ |
— |
— |
Turbidity (tungsten lamp) |
— |
— |
— |
○ |
○ |
water depth |
— |
— |
○ |
○ |
○ |
ORP (oxidation-reduction potential) |
○ |
○ |
○ |
○ |
○ |
GPS |
— |
— |
○ |
— |
Sensor probe
U-51 |
U-52 |
U-52G |
U-53 |
U-53G |
|
Multiple parameters that can be displayed simultaneously |
10 |
11 |
11 |
11 |
11 |
Measuring temperature |
-5-55 degrees Celsius |
||||
Sensor diameter |
Not exceeding approximately 96 millimeters |
||||
Probe length |
About 340 millimeters |
||||
Cable Length |
Standard 2 meters, |
Optional 10 meters |
30 meters |
||
quality |
About 1800 grams |
||||
Automatic calibration (using pH4) |
Suitable for all models |
||||
Turbidity cleaning brush |
– |
– |
– |
○ |
○ |
measured depth |
Can reach a depth of up to 30 meters |
||||
Liquid junction material |
PPS glass |
SIS316L |
SUS304 |
FKM |
PEEK |
|
Waterproof function |
Titanium FEP film JIS Level 8 |
POM
|
Control unit
U-51 U-52 U-52G U-53 U-53G |
|
External dimensions |
115 (width) X 65 (depth) X 280 (height) millimeters |
quality |
About 800 grams |
LCD |
320 X 240 with backlit LCD (black and white) |
data memory |
10000 sets of data |
communication |
USB peripherals |
battery |
4 C-type batteries |
Waterproof function |
JIS Level 7 (when connecting sensor cables) |
BATTERY LIFE |
U-51, U-52, U-52G: Approximately 70 hours (without backlight) |
U-53, U-53G: Approximately 500 measurements conducted |
|
Storage temperature |
-10-60 degrees Celsius |
ambient temperature |
-5-45 degrees Celsius |
pH(Applicable to all models)
Specification attribute |
Specification value |
measuring principle |
Glass electrode method |
range |
pH 0-14 |
resolution |
0.01pH |
repeatability |
± 0.05pH |
accuracy |
±0.1pH |
Dissolved oxygen (DO, applicable to all models)
Specification attribute |
Specification value |
measuring principle |
Polarographic method |
range |
0-50.0 mg/L |
resolution |
0.01 mg/L |
repeatability |
± 0.1 mg/L |
accuracy |
0-20 mg/L : ±0.2 mg/L, 20-50 mg/L: ±0.5mg/L |
Conductance (COND, applicable to all models)
Specification attribute |
Specification value |
measuring principle |
4 AC electrode method |
range |
0-10 S/m (0-100 mS/cm) |
resolution |
0.000-0.999 mS/cm:0.001 |
repeatability |
±0.05% F.S. |
accuracy |
± 1% F.S. (midpoint of two-point calibration) |
Salinity
Specification attribute |
Specification value |
measuring principle |
Conductivity conversion |
range |
0-70PPT (0.1%) |
resolution |
0.1PPT |
repeatability |
±1 PPT |
accuracy |
±3 PPT |
Total Dissolved Solids (TDS)
Specification attribute |
Specification value |
measuring principle |
Conductivity conversion |
range |
0-100 g/L |
resolution |
0.1F.S. |
repeatability |
± 2 g/L |
accuracy |
± 5 g/L |
Apparent specific gravity of seawater
Specification attribute |
Specification value |
measuring principle |
Conductivity conversion |
range |
0-50 δt |
resolution |
0.1 δt |
repeatability |
±2 δt |
accuracy |
±5 δt |
Temperature
Specification attribute |
Specification value |
measuring principle |
Thermistor method |
range |
-5-55 degrees Celsius |
resolution |
0.01 degrees Celsius |
repeatability |
± 0.10 degrees Celsius (calibration point) |
accuracy |
JIS B-grade, platinum thermosensitive electrode (± 0.3+0.005) |
Turbidity(TURB)
U-51 |
U-52 U-52G |
U-53 U-53G |
|
measuring principle |
– |
30 degree forward penetration and scattering method for LED light source |
Tungsten lamp light source 90 degree penetration and scattering method |
range |
– |
0-800 NTU |
0 -1000 NTU |
resolution |
– |
0.1 NTU |
0.01 NTU |
repeatability |
– |
± 5% (reading) or ± 0.5 NTU Whichever is larger |
± 3% (reading) or ± 0.1 NTU Whichever is larger
|
accuracy |
– |
± 5% (reading) or ± 1 NTU Whichever is larger
|
0 -10 NTU:±0.5 NTU |
water depth
U-51 |
U-52 |
U-52G U-53 U-53G |
|
measuring principle |
– |
– |
Pressure method |
range |
– |
– |
0-30 meters |
resolution |
– |
– |
0.5 meters |
repeatability |
– |
– |
±1% F.S. |
accuracy |
– |
– |
± 0.3 meters |
Redox potential (ORP)
Specification attribute |
Specification value |
measuring principle |
Platinum electrode method |
range |
-2000 mV - +2000 mV |
resolution |
1 mV |
repeatability |
± 5 mV |
accuracy |
± 15 mV |
GPS
12 channels (applicable to U-52G)