HMJBC-702 Microcomputer Relay Protection Tester

NegotiableUpdate on 07/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The HMJBC-702 microcomputer relay protection tester is an important testing tool for ensuring the safe and reliable operation of power systems. It can independently complete device testing in professional fields such as microcomputer protection, relay protection, excitation, metering, and fault recording, and is widely used in scientific research, production, and electrical testing sites in industries such as power, petrochemicals, metallurgy, railways, and military.

Product Details

HMJBC-702 Microcomputer Relay Protection Tester

Standard 4-phase voltage and 3-phase current output; Convenient standalone operation; Dual operation mode, connected to a computer for operation; The software has powerful functions and can complete various large-scale complex verification tasks with high automation levels; Rich switch contacts, 702 has 7 input contacts and 2 pairs of output contacts; Equipped with an independent dedicated DC power output device; There is a dedicated adjustable DC power output for 110V and 220V.

HMJBC-702 Microcomputer Relay Protection Tester

Technical Parameter

electricity

flow

transport

go out

hand over

flow

Phase current output (effective value) 0-40A/per phase

Triple current output (effective value) 0-120A

Long term allowable operating value (effective value) of phase current is 8A per phase

Phase current z · ui large output capacity 400VA

Three parallel current of 120A, z · ui large capacity of 900VA

Allowable working time of 30s when the current of the three parallel is 120A

Frequency range (fundamental) 20-400Hz

Harmonic order 1-9 times

straight

flow

Phase current output 0- ± 10A/per phase

Z · UI high output load voltage 20V

electricity

press

transport

go out

hand over

flow

Phase voltage output (effective value) 0-120V

Line voltage output (effective value) 0-240V

Phase voltage/line voltage output power 50VA/100VA

Frequency range (fundamental) 20-400Hz

Harmonic order 1-9 times

straight

flow

Phase voltage output amplitude 0- ± 140V

Line voltage output amplitude 0- ± 280V

Phase voltage/line voltage output power 50VA/100VA

Switching input

Empty contact 1-20mA, 24V

Potential contact input "0": 0-+6V; "1":+11V -+250V

Switching Output

Empty contact point DC: 220V/0.2A; AC:220V/0.5A

Time measurement

Measurement range: 0.1ms to 9999s

supply voltage

Allowable range AC220V ± 10%, 50/60Hz

ambient temperature

Allowable range -10 ℃ -+50 ℃

volume weight

Volume: 400 × 300 × 180mm3Weight: 18kg