E-mail
hblhyq@qq.com
-
Phone
15230711060
-
Address
Chengdong Industrial Development Zone, Xian County, Cangzhou City, Hebei Province
Hebei Longhui Highway and Railway Test Instrument Factory
hblhyq@qq.com
15230711060
Chengdong Industrial Development Zone, Xian County, Cangzhou City, Hebei Province
New standard asphalt mixture maximum theoretical density meter, asphalt mixture maximum theoretical relative density meter, asphalt maximum theoretical density meter, maximum theoretical density meter, asphalt mixture testing instrument, asphalt mixture maximum theoretical density meter *, asphalt mixture maximum theoretical density meter manufacturer
1、 The largest theoretical density meter for asphalt mixture, HDXM-21summary:
This instrument is suitable for determining the theoretical maximum relative density of asphalt mixtures using vacuum method, and is used for asphalt mixture mix design, road condition investigation, or pavement construction quality management calculation of void ratio, compaction degree, etc. This instrument is tested according to the T0711-2011 method in the "Test Code for Asphalt and Asphalt Mixtures in Highway Engineering" (JTGE20-2011).
2、 The largest theoretical density meter for asphalt mixture, HDXM-21Main technical parameters:
1. Power supply voltage: 220V ± 10V 50Hz
2. Vacuum density: -0.1MPa
3. Vibration gap: 3 minutes
4. Working mode: automatic/manual
5. Container capacity: 4300ml x 2 pieces
6. Pump power: 160W
7. Vibration motor power: 30W
8. Vacuum pressure: automatic control 0-100Kpa
9. Negative pressure inside the negative pressure container: 3.7KPa (27.75mmHg), allowable deviation ± 0.3KPa
10. Dimensions: 530 × 500 × 380mm
3、 Usage of the maximum theoretical density meter for HDXM-21 asphalt mixture:
According to the experimental regulations, the instrument is equipped with two program functions: automatic testing and manual testing. This instrument can simultaneously detect two parallel samples for comparison.
1. Connect the power supply (AC220V/50HZ), press the power switch, the power indicator light will turn on, and wait for the test.
2. Place the negative pressure container (hereinafter referred to as the material cylinder) together with the water (water temperature of 25 ℃± 0.5 ℃) and the mixture on the vibration platform (the injected water should submerge the mixture completely). Cover the cover plates of the two material cylinders with three joints (one of which is connected to a precision digital pressure gauge with a label), insert the three exhaust pipes, and rotate the air release valve to the closed position (left turn of the air release valve is open and right turn is closed).
3. Automatic program:
After resetting the system by pressing the "stop" button, press the "automatic" button, and the automatic indicator light will turn on. According to the preset program of the instrument, the instrument will first pump air for two minutes to count the time. During the pumping process, the pressure regulating valve will be rotated (the left rotation number of the pressure regulating valve will increase and the right rotation number will decrease), so that the vacuum degree of the material cylinder reaches 3.7Kpa (± 0.3Kpa). After two minutes of pumping, the counting board will return to zero and start timing again. The vacuum pump and vibration worktable will work synchronously for 15 minutes (± 2min) and then stop working at the same time. The system will exit the "automatic program".
3.2 In the automatic program, press the "stop" button to exit the automatic program and reset the system. The automatic program test has ended, and the operator believes that the test has met the requirements. Therefore, the air release valve can be rotated slowly to release pressure (the pressure release speed can be controlled by reading the vacuum gauge, and the pressure release speed should not exceed 8Kpa/s), gradually restoring the pressure inside the material cylinder to atmospheric pressure.
4. Manual program:
4.1 Press the "Extract" button first, and the vacuum pump and timer will start working. The "Manual" indicator light will turn on. During the extraction process, rotate the pressure regulating valve (the left rotation number of the pressure regulating valve increases and the right rotation number decreases) to achieve a vacuum degree of 3.7Kpa (± 0.3Kpa) in the material cylinder.
4.2 Press the "Vibration" button to synchronize the vibration worktable and vacuum pump. The timer will reset to zero and start counting again. If the operator deems the test to meet the requirements, press the "Stop" button to stop both the vacuum pump and vibration worktable. If further vibration is required, repeat the steps in 4.2 above. The manual program test is completed, and the operator considers that the test has met the requirements. Therefore, the air release valve can be rotated slowly to release pressure (the pressure release speed is controlled by reading the vacuum gauge, and the pressure release speed should not exceed 8 Kpa/s), gradually restoring the pressure inside the material cylinder to atmospheric pressure.
This method is not applicable to asphalt mixtures with porous aggregates that have a water absorption rate greater than 3%.
4、 Precautions for the maximum theoretical density meter of HDXM-21 asphalt mixture:
1. The instrument is equipped with an air drying device to ensure that the gas entering the vacuum pump is dry gas. If water is found to be drawn into the pipeline due to incorrect operation, the back cover of the box should be opened and the drying device should be opened for drying treatment.
2. After the vacuum pump is started, if the vacuum gauge pointer stops moving or keeps shaking in place, it is due to poor sealing of the material cylinder or leakage of the pipeline. If the sealing of the material cylinder is not tight, the operator can use their hands to slightly press down on the circumference of the cylinder cover, and release it after the pointer rotates normally.
3. After the experiment is completed, the test cylinder should be cleaned in a timely manner, and any water stains on the cylinder, cylinder cover, vibration table, and instrument should be wiped dry.
4. After unpacking the packaging box, install the instrument horizontally in a dry, ventilated, and clean place, with an ambient temperature not exceeding 40 ℃.
5. It is strictly prohibited to drop water droplets into the instrument box due to operational errors.
6. Non professional technical personnel of our company are strictly prohibited from dismantling the protective plates of various parts of the instrument, except for changing the oil and drying equipment. Violators are responsible for any damage caused to the instrument.
7. Maintenance and upkeep of vacuum pump precautions:
(1) The temperature of the extracted gas cannot exceed 40 ℃, and the operating environment temperature is between 5 ℃ and 40 ℃.
(2) It is strictly prohibited to operate without oil. When the pump is running, it is strictly prohibited to block the exhaust port. During the experiment, oil mist like gas will be emitted from the box, which is a normal phenomenon.
(3) Long term work should regularly pay attention to whether the pump oil is sufficient, and the oil level in the tank should not be lower than the center of the oil gauge. Insufficient oil level will affect work performance and even damage parts.
(4) To maintain the cleanliness of the oil, it is required to replace the new pump with new oil every 250-300 hours after use. If the pump oil becomes dirty, turbid, or contains water or other volatile substances during use, it should be replaced with new oil in a timely manner to avoid affecting the vacuum degree or preventing operation. Use vacuum pump oil or mechanical oil of grade 20 or above.
(5) Before replacing the new oil, the pump should be turned on and run for 15-30 minutes to make the oil thinner. After stopping the pump, unscrew the oil drain screw to drain all the dirty oil in the pump. Then, pour 300ml of new oil into the inlet and run the motor for 1 minute to clean the inside of the pump chamber. Repeat this process 2-3 times to confirm cleanliness, and then install new oil before use.
8. The usage method of high-precision digital pressure gauge (pressure gauge division value of 0.1 Kpa, indication error of 0.2 Kpa): Function in sampling state: (please use a magnetic pen when operating the panel) "On/Off" button: Power on/off function button;
When the instrument is not in use, sampling can be turned off to reduce efficiency. Brushing this button displays the starting point and full range point of the instrument range within 2 seconds, and the instrument enters the measurement state; After pressing this button again for 2 seconds, the instrument panel will shut down.
The "Settings" button has two functions, namely the "Peak Hold" function and the "Unit Conversion" function. All parameters of this product have been set and there is no need to perform this operation.
Zero calibration button: Due to changes in atmospheric pressure and temperature, the digital pressure gauge can automatically calibrate the zero pressure by pressing this button when there is zero drift at atmospheric pressure. Pressing this button will display 'CAL-0' and the instrument will perform zero calibration. Normally, it will automatically exit and hold within 2 seconds. If the current pressure is within the atmospheric pressure range, "CAL-0" can be displayed for zero calibration; If there is a significant difference between the pressure and atmospheric pressure or if there is an instrument malfunction, the side display "ERR01" indicates an instrument malfunction.
Power supply for digital pressure gauge: 3.6V high-energy dual cell lithium battery with a lifespan of 2 to 3 years.
Longhui Company mainly produces and suppliesHighway testing instrument seriesAsphalt mixing plant experimental instrument、Asphalt mixing plant testing instruments, asphalt mixing plant laboratory instrumentsCommercial concrete mixing plant laboratory instruments and equipment, asphalt mixing plant testing instruments, concrete drilling and coring machine series, fully automatic curing room equipment series, constant temperature and humidity standard curing box series, cement concrete pressure testing machine series, material testing machine series, concrete single axis mixer series, cement electric bending testing machine series, electric hot air drying box series, concrete freeze-thaw testing machine series, cement testing and inspection instruments and equipment, concrete testing and inspection instruments and equipment, asphalt testing and inspection instruments and equipment, highway testing and inspection instruments and equipment, geotechnical testing and inspection instruments and equipment, mortar testing and inspection instruments and equipment, non-destructive testing instruments and equipment. We can set up complete sets of instruments and equipment for first, second, and third level laboratories for our clients and friends (commercial concrete mixing plant instruments and equipment). Our products (except for vulnerable parts) are covered by a one-year warranty. If there are any quality problems within six months (except for user operated reasons), they will be replaced and repaired for life. Company
Longhui Company specializes in contracting:
A. Design and equipment configuration business for laboratories A, B, and C.
B. Design and equipment configuration business for P1, P2, and P3 level laboratories.
The integrity, strength, and product quality have been recognized by the industry. Welcome friends from all walks of life to visit, guide and negotiate business. We will be dedicated to serving you.
Hebei Longhui Highway and Railway Test Instrument Factory