132SB Guangming Physical and Chemical Vinyl Chloride Gas Detection Tube, Other Harmful Effects: Vinyl chloride can participate in photochemical smog reactions in the environment. Due to its strong volatility, it is easily photodegraded in the atmosphere, and can also be biodegraded and chemically degraded. It can be destroyed by specific bacterial communities and oxidized by oxygen in the air to form benzyl ether, formaldehyde, and a small amount of phenylethanol.
132SBGuangming Physical and Chemical Chloroethylene Gas Detection TubeDetection range: 5-500ppm

132SBGuangming Physical and Chemical Chloroethylene Gas Detection Tube
*Convenient gas toxin detection tube for occupational health inspection
Customized testing equipment, made in China, can provide customized testing tubes for different provinces and projects.
Convenient detector, including: hand pump, 11 types of gas detection tubes, and detection box.
1. Purpose: Used for semi quantitative detection of toxic gas concentrations in the air of workplaces by occupational health law enforcement personnel.
2. Requirements:
(1) General requirements: Compact and easy to carry, no need for power and heat sources, no need for analytical instruments and chemical reagents, no need for sample pretreatment, can directly perform semi quantitative measurements, can be read quickly on site, and provide user manuals.
(2) Performance requirements: Toxic gas detection tubes have different detection ranges, which can be selected according to different detection purposes and the concentration of toxic gases on site. Choose as much as possible to detect toxicityqiA detection tube with an occupational exposure limit level of 10% to 200%.
Gas detection tube (toxic gas detection tube)
Reference as follows:
Carbon monoxide (detection concentration range: 3mg/m3~60mg/m3, the same below), hydrogen sulfide (1mg/m3~20mg/m3), CL2 (0.1mg/m3~2mg/m3), carbon dioxide (1800mg/m3~36000mg/m3), ammonia (3mg/m3~60mg/m3), sulfur dioxide (1mg/m3~20mg/m3), nitrogen oxides (1mg/m3~20mg/m3), hydrogen chloride (0.75mg/m3~15mg/m3), hydrogen fluoride (0.2mg/m3~4mg/m3), ozone (0.03mg/m3~0.6mg/m3), formaldehyde (0.05mg/m3~1mg/m3), etc.
*Convenient gas toxin detection tube for occupational health inspection
Product Name |
model |
measurement range |
Specifications |
carbon monoxide |
定制 |
3-60mg/m³ |
20 pieces/box |
hydrogen sulfide |
定制 |
1-20mg/m³ |
20 pieces/box |
CL2 |
定制 |
0.1-2mg/m³ |
20 pieces/box |
carbon dioxide |
定制 |
1800-36000mg/m³ |
20 pieces/box |
ammonia |
定制 |
3-60mg/m³ |
20 pieces/box |
sulfur dioxide |
定制 |
1-20mg/m³ |
20 pieces/box |
nitrogen oxides |
定制 |
1-20mg/m³ |
20 pieces/box |
hydrogen chloride |
定制 |
0.75-15mg/m³ |
20 pieces/box |
hydrogen fluoride |
定制 |
0.2-4mg/m³ |
20 pieces/box |
formaldehyde |
定制 |
0.05-1mg/m³ |
20 pieces/box |