Instrument function: $r $n1, graphite furnace heating method. $r$n2、 Silicate insulation method. $r$n3、 The whole machine chassis is made of stainless steel material, which has good corrosion resistance. $r$n4、 The temperature inside the furnace is continuously adjustable. $r$n5、 The whole machine has multiple protections such as overvoltage, overcurrent, and overheating. $r$n6、 The average temperature difference inside the furnace is small, the consistency of sample digestion effect is good, and the heat conduction efficiency is high.
Product Details

Instrument function:

1. Graphite furnace heating method.
2. Silicate insulation method.

3. The whole machine chassis is made of stainless steel material, which has good corrosion resistance.

4. The temperature inside the furnace is continuously adjustable.
5. The whole machine has multiple protections such as overvoltage, overcurrent, and overheating.

6. The average temperature difference inside the furnace is small, the consistency of sample digestion effect is good, and the heat conduction efficiency is high.

Technical Specifications:


1. Working conditions: 1.1 Environmental temperature: 0 ℃~50℃; 1.2 Relative humidity: 10% to 90%;
1.3 Applicable power supply: voltage 220V (± 10%), 50Hz (± 2%);
2. Main technical indicators: 2.1 Can be processed simultaneously30A sample with a digestive tract specification of100ml; 2.2 54 heating program selections,; 2.3 Electronic programmable control, automatically setting the temperature from room temperature to350℃; 2.4 Temperature accuracy ± 05℃; 2.5 Temperature stability ±1℃; 2.6 Heating time setting 1-999 minutes; 2.7 Contains overheat protection device;; 2.9 The digestion results have high repeatability, reliability, and safety, saving reagents and working time and space;

3. Diameter: 32mm. Hole depth: 60mm, PTFE coated graphite.

36 holes

Customized according to requirements

Technical Specifications:


1. Working conditions: 1.1 Environmental temperature: 0 ℃~50℃; 1.2 Relative humidity: 10% to 90%;
1.3 Applicable power supply: voltage 220V (± 10%), 50Hz (± 2%);
2. Main technical indicators: 2.1 Can be processed simultaneously30A sample with a digestive tract specification of100ml; 2.2 54 heating program selections,; 2.3 Electronic programmable control, automatically setting the temperature from room temperature to350℃; 2.4 Temperature accuracy ± 05℃; 2.5 Temperature stability ±1℃; 2.6 Heating time setting 1-999 minutes; 2.7 Contains overheat protection device;; 2.9 The digestion results have high repeatability, reliability, and safety, saving reagents and working time and space;

3. Diameter: 32mm. Hole depth: 60mm, PTFE coated graphite.

36 holes

Customized according to requirements