Glass component content detection machine equipment

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The glass composition content detection machine equipment has convenient and intuitive software operation, with qualitative, semi quantitative, and quantitative analysis functions, as well as instrument diagnostic optimization functions. The software is fully in Chinese and can be switched according to needs. The report format output format is PDF, Excel, electronic file or direct printing, and can be a Chinese template. The control software can run on the Chinese version of Windows 7 and XP. The software comes with an automatic sampler control interface.

Product Details

Glass component content detection machine equipment

Performance Characteristics

Safe and reliable solid-state RF power supply
The RF power supply used in the instrument has small size, high output efficiency, stable output power, and various safety protection functions such as water, gas, and overload, greatly improving the safety of the instrument and reducing its failure rate.
High degree of instrument automation
The degree of automation of the instrument *, except for the power switch, all operations are completed by software. Intelligent software that can provide real-time feedback and information prompts for various operations.
Fully automatic ignition and matching technology
The software can automatically ignite with one click, and all parameter settings changes are automatically completed. Combined with *'s automatic matching technology, the ignition success rate is high and the operation is simple.
Intelligent flame monitoring function
The instrument is equipped with a fiber optic sensor with sensitivity *, which can monitor the working condition of the flame in real time while the instrument is in operation. In case of abnormal flameout, the instrument can be automatically turned off.
High precision airflow control system
The plasma gas, auxiliary gas, and carrier gas used in the operation of the instrument are all controlled by high-precision mass flow controllers (MFCs), which have continuously adjustable flow rates and high accuracy in outputting airflow, ensuring the accuracy of test data.
Peristaltic pump injection device
The instrument is equipped with a high-precision peristaltic pump with four channels and twelve rollers, which can simultaneously ensure the accuracy of sample injection and prevent liquid accumulation. The rotational speed of the peristaltic pump is continuously adjustable to meet various testing requirements of customers.
Ultra high resolution optical path system
The instrument is equipped with an imported grating with ultra-high resolution 4320 engraved lines, which is matched with *'s optical path adjustmentTechnology reduces the resolution of ordinary instruments from about 0.008nm to within 0.005nm, and the ultra-high resolution ensures that there is no mutual interference between test elements.
Constant temperature system with precision *
The overall optical path of the instrument is protected by a precision constant temperature system, and the temperature control can be set in real time according to the actual environmental temperature of the customer's laboratory, without the need for long-term continuous adjustment. The temperature control accuracy is ≤± 0.1℃The precise constant temperature system ensures the stability of the optical path, and the test data is more stable.
Sensitivity * detector
The instrument is equipped with a high-sensitivity imported photomultiplier tube (PMT) as the detector, which can automatically set test parameters for different elements to achieve the ideal detection state and provide accurate test results. No need for refrigeration, no need for blowing, long service life.
Ultra low usage cost
When the instrument is not in operation, the power supply, cooling water tank, and gas are all turned off without any cost. The instrument can be used immediately without the need for prolonged preheating of the optical path. Using argon gas with a purity of 99.99% is sufficient, eliminating the need for high-purity argon with a purity of 99.999%, resulting in cost savings of at least one-third.

Main technical parameters of the product
1. Independently developed all solid state RF power supply, with output power of 800-1600W, continuously adjustable, power efficiency greater than 65%, operating frequency of 27.12MHz, frequency stability<0.05%, power output stability<0.05%.
2. Fully automatic one key ignition, automatic matching, stable and convenient ignition.
3. Adopting a concentric circle atomizer combined with a swirl chamber, with a 1ppm Mn intensity greater than 1000000 CPS
4. Adopting Czerny Turner type optical path with a focal length of 1000mm
5. Ion etched holographic grating with a engraved area of (80 × 110) mm
6. Resolution (Mn257.610nm): ≤ 0.005nm (4320 line grating); ≤ 0.008nm (3600 line grating); ≤ 0.015nm (2400 line grating)
7. Wavelength range: 190-460nm (4320 line grating); 190-500nm (3600 line grating); 190-800nm (2400 line grating)
8. Input power supply: voltage AC 220V, current 20A.
Application field
Provide customers with comprehensive pre-sales, in sales, and after-sales service solutions
environmental protection industry
Accurately and quickly analyze the elemental composition of environmental samples (water quality, soil, atmosphere) to safeguard human daily life.
Geological and mining industry
Accurate and rapid analysis of mineral content has strict guiding significance for early mining, mid-term control, and later restoration of mines.
Metallurgical industry
The analysis of product ingredients can provide real-time control over the production process and technology, ensuring the ingredient content of the final product and meeting the quality requirements of the final product.
Toy and consumer goods industry
Analyze heavy metal elements in children's toys and consumer goods to ensure that the content of heavy metal elements in the produced products is within the controlled range, allowing parents and children to feel more at ease.
Precious metal industry
The content of impurity elements in precious metals directly affects the purity and performance of precious metals, and determines the value of precious metals themselves. Accurately determining the content of low impurity elements is extremely important for the precious metal industry.
Rare earth industry
The value and use of rare earth elements are increasingly favored, and the application range of high-purity rare earth elements is also becoming wider. The analysis of impurity elements is particularly important, and the requirements for accuracy and efficiency in rare earth testing can be met.
other industries
Industries with requirements for element detection in other teams

Glass component content detection machine equipment