Welcome Customer !

Membership

Help

Shanghai Beilan Optoelectronics Technology Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Shanghai Beilan Optoelectronics Technology Co., Ltd

  • E-mail

    ryu@ultrablue-sci.com

  • Phone

    13331917708

  • Address

    Room 1019, Building 3, Lujiazui Financial District, No. 555 Nanyang Jing Road, Pudong New Area, Shanghai

Contact Now

GL SPECTIS 6.0 Spectrometer

NegotiableUpdate on 05/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The GL Spectis 6.0 LED spectrometer is specifically designed and developed for high-speed measurement of SSL products (IESNA LM-79-08), LED chips, large street lamps, and lighting fixtures. It has been optimized for production and large laboratory settings to comply with the new CIE S025 standard.

Product Details

The GL Spectis 6.0 LED spectrometer is specifically designed and developed for high-speed measurement of SSL products (IESNA LM-79-08), LED chips, large street lamps, and lighting fixtures. It has been optimized for production and large laboratory settings to comply with the new CIE S025 standard.

The GL Spectis 6.0 LED spectrometer uses a high-resolution optical system with a single sensor and diffraction grating, which can cover a very wide spectral range. The average optical solution is 3.5 nm, with a data point spacing of 0.5 nm, making it a very versatile instrument for different types of measurements.

The GL Spectis 6.0 LED spectrometer uses an industry standard 19 inch rack housing that can be easily integrated into production testing systems and larger laboratory settings, including power measurement, TEC systems, triggers, and other testing equipment. The available USB and serial interfaces simplify integration with different types of control software and data systems.

The wavelength range of Spectis 6.0 is from 200 to 1050nm and can be measured according to many standards, including photobiological safety (IEC EN 62471) or measurement of SSL products (IESNA LM-79-08) and CIE. S025 standard. A device can cover many different types of measurements.

Measurements were completed according to CIE 127:2007 and CIE 025/E: 2015.

Photobiological safety testing of LED products in accordance with EN 62471.

Comply with the SSL product measures of (IES) LM-79-08.

Complies with the ecological design requirements of (EU) No 1194/2012.

GL SPECTIS 6.0光谱仪(图1)

System functions

  • Photometric and radiometric calibration

Before delivery, spectral calibration is integrated into each spectrometer to accurately measure different values (such as lux, candela, or lumens) and radiance values, depending on the installed measurement accessories.

  • Dark current compensation

Although it is not a cooling detector, Spects 6.0 can still provide very accurate measurements under different conditions. The temperature sensor installed on the electronic board monitors temperature changes and automatically compensates for any changes in dark current levels, ensuring excellent measurement stability.

  • Provide multiple integrating spheres and probes

With the universal concept and design of Spectis 6.0, you can easily expand your measurement system by adding any of our integrating spheres or other accessories.

  • Automatic attachment detection

The mechanism of Spectis 6.0 can detect and automatically load the correct calibration file for the attachment. This allows users to confidently avoid measurement errors when changing attachment interfaces. The calibration meets the requirements of the standard organization and has obtained certification confirmation from the manufacturer.

GL SPECTIS 6.0光谱仪(图2)

system metrics

  • Lux/Lux - irradiance

  • Lumen/Lumen - Luminous flux

  • CRI - Color rendering index (compliant with CIE standards)

  • CCT - Color Temperature (in accordance with the standard CIE)

  • Color - Chromatic Coordinates (CIE 1931 and CIE 1964)

  • Fidelity and Color Gamut - Method for Evaluating Light Source Color Restoration According to TM-30 IES Standard

  • PAR/PPFD - photosynthetically active radiation measurement (horticulture)

  • EML - Equivalent Black Luminous Lux/Equivalent Black Luminous Illumination

  • MWatt - Radiant Energy

GL SPECTIS 6.0光谱仪(图3)

System specification parameters

Spectral Range*

340-850nm / 200-800nm / 380-1050nm / 200-1050nm

sensor

Back illuminated CCD image sensor

pixel count

2048

Physical resolution

〜0.5 nm

Optical resolution/FWHM

2.5 nm

Wavelength reproducibility

±0.5nm

integration time

10ms~10s (in automatic mode)

A/D conversion

16bits

signal-to-noise ratio

1000:1

stray light

2*10E-4

Measurement accuracy of spectrophotometry**

6% (within the range of 200-220 nm), 5% (within the range of 220-500 nm), 4% (within the range of 500-1050 nm)

Measurement uncertainty of color coordinates (x.y)**

0.0015

Illuminance (lux)

1 lx … 200,000 lx

Brightness [cd/m ²]

Provided together with the optional GL Opti probe

Luminous flux [lm]

Provided together with the optional GL Opti probe

Luminous intensity [cd]

Calculate with SPECTRSOFT

Equipped with temperature monitoring sensor system

PC interface

USB 2.0

data format

XML

Full-color display screen

240x320px

Micro SD card

4GB

power adapter

Power supply unit 100... 240 V (50/60 Hz) 0.15 A

Operating Temperature

5-35°C

Dimensions [H x W x D]

2U 19” | 480 x 262 x 88.9 mm

weight

2500g

*The spectral range of the sensor. Due to limitations in the use of optical accessories, the actual spectral range of the system may be reduced.

**Measurement uncertainty occurs immediately after calibration. The expanded uncertainty corresponds to a coverage probability of 95%, with a coverage factor of k=2.

This parameter is effective under laboratory conditions of 25 ° C and relative humidity of 45%

Attention: Instrument, firmware, and software specifications are subject to change without prior notice. All information contained in the GL OPTIC data sheet, as well as any form of product information, has been carefully prepared and includes truthful information. Please note that differences may occur due to text and/or other errors or changes in available technology. It is recommended to contact us before using the product to obtain the product specifications.

Suitable for:

  • Lamp manufacturer

  • Lighting testing agency

  • Environment or personnel related to lighting inspection and testing

  • Suitable for various optical measurement applications from laboratory to on-site testing