The Picarro G2132-i isotope analyzer is capable of accurately measuring the ratio of stable isotope 13C-12C in methane (CH4). Methane is both a valuable energy source and a greenhouse gas. Scientists use the Picarro G2132-i analyzer to accurately measure the ratio of 13C-12C, which can determine whether methane is emitted from dairy farms, landfills, or hydraulic fracturing wells, as well as identify methane sources and sinks in wetlands.
--Perform isotope measurements with excellent accuracy and stability to identify key methane sources
--Direct measurement of CH4- no need to prepare any samples or perform drying treatment
--Reduce calibration, minimize maintenance, and eliminate the need for consumables
--Equipped with ChemDetect ™, Detectable pollutants in the sample

The G2132-i analyzer can be paired with various peripheral devices to extend and expand its functionality.
| Picarro G2132-i methane (CH4) | ||
| In CH4δAccuracy of 13C (1)-σ, 1-hour window) | 5-minute mean ensures accuracy<0.8 ‰, when ch4 is greater than 1.8 ppm The 15 minute mean ensures an accuracy of<0.5='' ‰, and when ch4='' is greater than 1.8='' ppm=''> |
Ensure accuracy<0.4 ‰, when='' ch4='' is greater than='' 10='' ppm=''> |
| CH4 at standard temperature and pressureδThe maximum drift of 13C (the difference between the maximum value of the 1-hour average within 24 hours) | Ensure drift<1.5 ‰, at='' ch4=''='' 10='' ppm=''> Typical drift<2 ‰, at='' ch4=''='' 1.8='' ppm=''> |
Ensure drift<1.5 ‰, at='' ch4=''='' 10='' ppm=''> |
| Accuracy of CH4 concentration (30 seconds, 1)-σ) | 5 ppb+0.05% (12C) reading 1 ppb+0.05% (13C) reading |
50 ppb+0.05% (12C) reading 10 ppb+0.05% (13C) reading |
| Accuracy of CO2 concentration (30 seconds, 1)-σ) | 1 ppm+0.25% (12C) reading | |
| Accuracy of H2O concentration (30 seconds, 1)-σ) | 100 ppm | |
| CH4 dynamic range | Ensure a range of 1.8-12 ppm The working range is 1.2-15 ppm |
Ensure a range of 10-1000 ppm The working range is 1.8-1500 ppm |
| CO2 dynamic range | Ensure a range of 200-2000 ppm The working range is 100-4000 ppm |
|
| H2O dynamic range | Ensure a range of 0-2.4% and a working range of 0-5% | |
| Environmental temperature dependence | Ensure value<± 0.06 ‰='' ℃, typical value=''><± 0.025 ‰=''> | |
| Measurement intervals (including regular H2O and CO2 measurements) | About 2 seconds | About 2 seconds |
| Rise time/fall time (10-90%/90-10%) | The typical value is about 30 seconds | |
| Application precautions | When the concentrations of H2O and CO2 are much higher than normal environmental levels, or when other organic compounds such as ammonia, ethane, ethylene, or sulfur-containing compounds are present, measurements may be disrupted. Users should use prepared laboratory standard samples for validation. For more details about the experimental conditions, please contact us. When the system is used in recycling applications, the pressure drop in the instrument air path can draw in external air. | |
| Picarro G2132-i Instrument Specifications | ||
| measurement | Cavity ring down spectroscopy (CRDS) technology | |
| Measurement pool temperature control | ±0.005 ℃ | |
| Measurement pool pressure control | ± 0.0002 atmospheric pressure | |
| Shock and vibration testing | Meets the impact and vibration MIL-STD 810F testing standards and operates as specified | |
| sample temperature | -10 to 45 ℃ | |
| Sample pressure | 300 to 1000 Torr (40 to 133 kPa) | |
| Sample flow rate | Less than 50 standard milliliters per minute (sccm) at 760 pallets (usually around 25 sccm), no filtration required | |
| Sample humidity | Relative humidity (RH) less than 99%, no need to dry under non condensing conditions at 40 ℃ | |
| Temperature range | 10 to 35 ℃ (during operation) -10 to 50 ℃ (during storage) | |
| ambient humidity | Relative humidity (RH) less than 99%, under non condensing conditions | |
| attachment | Pump (external), keyboard, mouse, LCD monitor (optional) | |
| data output | RS-232、 Ethernet USB、 Simulation (optional) 0-10 volts | |
| Air inlet connector | ¼ inch Swagelok ® | |
| External dimensions | Analyzer: 17 inches wide x 7 inches high x 17.6 inches long (43.2 x 17.8 x 44.6 centimeters), excluding 0.5 inch feet External pump: 5.6 inches wide x 6.4 inches high x 11.9 inches long (14.3 x 16.3 x 30.3 centimeters) |
|
| Installation form | Workbench or 19 inch rack mounted chassis | |
| weight | 60.4 pounds (27.4 kilograms), including external pump | |
| Power requirements | 100-240 volts AC, 47-63 Hz (automatic detection), starting (total) less than 260 watts; 125 watts (analyzer), 80 watts in steady state (pump) | |