■meet the standard
■technical indicators
| technical project | Functional indicators | Characteristics of indicators |
| 1. Move/static | Analysis algorithms: height measurement method, angle measurement method, circular ring method, ellipse method, tangent methodY-Llaw | The manual analysis function and automatic analysis function can be freely switched Capable of testing and comparing left contact angle, right contact angle, and average contact angle separately Has special surface analysis functions such as concave, convex, curved, superhydrophilic, superhydrophobic, etc Analysis function with irregular and non axisymmetric intrinsic contact angle Analysis function with forward contact angle, backward contact angle, and rolling angle Batch testing function with automatic analysis of contact angle change process |
| Measuring range0°~180° Measurement accuracy: ±0.1° measurequantityResolution:0.001° | Provide calibration blocks for full-scale calibration at any time, ensuring that the accuracy of contact angle measurement is within the error range |
|
| 2. Surface/interface | Analysis algorithm: manual method, automatic method | The manual analysis function and automatic analysis function can be freely switched Batch testing function with automatic analysis of dynamic changes in tension |
| Measuring range0.01~2000mN/m Measurement accuracy: ±0.1% Measurement resolution:0.001mN/m | It is recommended to calibrate the surface tension by measuring the surface tension values of distilled water at different temperatures It is recommended to calibrate the interfacial tension by measuring the interfacial tension values between n-butanol (or benzene) and water at different temperatures |
|
| 3Estimation of surface energy | Estimation Model:FowkesExpansionFowkesTheOwens-WendtThevan OSSTheWuHarmonic average method, equation of state method | Can be applied to the analysis of solid surfaces with polarity, non polarity, low energy, and high energy, respectively Solid surface energy, dispersion force, polarity force, hydrogen bonding force, van der Waals component, Lewis acid component, Lewis base component, etc. can be obtained separately |
| Liquid database:preset37 typesCommon liquidsSurface tension and its component data | The data can be directly imported for surface energy estimation liquid librarydataYou can add, delete, and modify on your own |
|
| 4Wettability analysis | Adhesion work, spreading coefficient, and adhesion tension | The wetting degree of the liquid on the solid can be analyzed by introducing the surface tension of the liquid and the contact angle with the solid |
| 5Data management | Save experimental information, data, and images through experimental templates | The newly created test template can be repeatedly imported and used after being saved The saved experimental data corresponds one-to-one with the images, making it easy to search The experimental data can be modified, deleted, and imported for reanalysis The experimental data can be annotated on the image and saved together with the image The test results can be exported toWordTheExcelandPDF |
| 6Image capture | Single shot, continuous shot, image playback, and video recording | Can set frame rate for continuous shooting or high-speed continuous shooting at camera frame rate, and can automatically replay all continuous shooting images You can choose to use the camera's external viewing function to automatically shoot without any time lag The dynamic changes of solid liquid gas three-phase can be recorded as a video for playback observation and process demonstration |
| 7Optical imaging system | Camera:300Ten thousand pixels, frame rate36frame/second camera lens:0.6~4.0Continuous zoom, working distance Focusing range: ± Horizontal and pitch adjustment range: ±2° Backlight source:LEDcold light source+Light blocking board, infinite brightness adjustment | The shooting part has horizontal and pitch adjustment functions Software automatically detects clarity during focusing, eliminating human error When shooting, the picture is smooth, the imaging contour is clear, and there is no distortion The contour recognition rate during automatic fitting can reach sub-pixel level |
| 8.dripsystem | Dropping method: software controlled automatic Minimum droplet volume:0.1Ml/drop Dropping accuracy: ±0.05Ml | Can achieve single automatic dripping, cyclic automatic dripping, automatic liquid extraction, and automatic lifting, etc The volume, speed, time interval, number of cycles, and lifting height of titration can be set |
| 9Tilt the sample stage | Table size:X100×Y Mobile itinerary:X50×Y50×Z Mobile mode: software controlled automatic+Hand controlled joystick | Mobile positioning can be controlled through software or achieved by operating the joystick separately from the software The conditions of moving distance, moving speed, and dwell time can be set Can choose single point automatic movement or multi-point automatic movement according to the preset program The trajectory of multi-point movement can be pre-set and saved, and can be repeatedly imported and used afterwards |
| Tilt mode: software controlled automatic Tilt range:0°~±90° Tilt accuracy: ±0.01° Speed ratio:1:60 | Implement coaxial overall tilt including sample stage, imaging system, and droplet system Can ensure that the droplet remains at the center of the window during the tilting process, without the need for manual adjustment The tilt direction and speed can be set, and the rolling angle is displayed accurately in real-time and can be exported |
|
| 10Host parameters | Size:W585×D280×H Weight: power supply1∮AC220V 50HZ | |