Fluorine and chlorine analyzer

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The fluorine and chlorine element analyzer is mainly used for the determination of chlorine in coal, iron ore, nickel ore, and graphite. According to GB/T176-2017 and GB/T3558, the high temperature combustion hydrolysis potentiometric titration method is used to determine the total fluorine and chlorine content in substances, which can be used in laboratories of coal, power, metallurgy, geological exploration and other departments.

Product Details

Fluorine and chlorine analyzerProduct Overview:

This experimental equipment uses a high-temperature combustion hydrolysis method to obtain fluoride and chloride ion sample solutions. The fluoride electrode is used as the indicator electrode, and the saturated calomel electrode is used as the reference electrode. The fluoride ion concentration in the sample solution is measured using the standard addition method, and the fluoride and chloride content in coal is calculated, which meets the requirements of the national standard "Determination Method for Fluorine and Chlorine in Coal".
Test principle:
Coal samples are mixed with a small amount of quartz sand and burned and hydrolyzed in a gas stream mixed with oxygen and water vapor at a high temperature of 1100 ℃. Various forms of fluorides in coal are converted into volatile fluorides and quantitatively dissolved in water. The fluoride electrode is used as the indicator electrode, and the saturated calomel electrode is used as the reference electrode. The fluoride chloride ion concentration in the sample solution is measured using the standard addition method to calculate the fluoride chloride content in coal.

Functional features:

lAdopting Chinese LCD display, the interface is friendly and the operation is simple.

lAdopting PID control for furnace flow, with high temperature control accuracy, effectively extending the service life of silicon carbon tubes.

lThe temperature measurement adopts high-precision and low-temperature drift components to ensure the accuracy of temperature measurement.

lOn the basis of the first generation equipment, this instrument has improved the sample delivery device, changing from manual sample delivery to continuous automatic sample delivery, avoiding the disadvantages of manual sample delivery and easy cracking of the reducer due to explosion.

lSupporting timed sample delivery reminder function, sample delivery is more stable and continuous, improving the accuracy of inspection resultsSimplified the operating procedures for experimental personnel.

lSupport fault self diagnosis function and over temperature protection function.

lThe evaporation capacity regulating potentiometer adopts Taiwan, China TOCOS potentiometer, with high linearity and long service life.

lConfiguring a high-precision digital ionizer ensures the accuracy of the experiment.

lThe automatic calculation software for the delivery upper computer inputs experimental data and automatically generates measurement results, eliminating the need for complex calculation processes for users. It saves data, makes queries convenient and concise, and provides clear and centralized information at a glance.

lThe test sample includes a refrigeration cycle system, and the next sample can be tested without cooling.

Technical Specifications:

lTemperature control accuracy: 1100 ± 2 ℃.

lHeating time: Approximately 25 minutes to raise the temperature to 1100 ± 2 ℃.

lTemperature setting range: 900 ℃ -1200 ℃.

lFluorine measurement range: 0.01% -0.2% Chlorine measurement range: 0.003% -1.0%

lAnalysis cycle: hydrolysis time for chlorine (30 min/sample), fluorine (30 min/sample)
Analysis time for chlorine (30 min/sample), fluorine (30 min/sample)

lSingle section high-temperature furnace: Temperature control range: 0-1200 ℃ Heating current: 0-10A

lOxygen rotor flowmeter: range 1000ml/min, small scale: 50ml/min

lTest method: High temperature combustion hydrolysis method.

lPrecision: Complies with GB/T 4633-2014 national standard.

lPower supply: AC 220V ± 10%, 50Hz.

lWhole machine power: ≤ 3.5KW.