Product Details: Fisher DVC6200 Positioner Fisher DVC6200 Series Digital Valve Controller. Added instruments with connectionless and contactless feedback technology; It is specifically designed for applications with strong vibrations, severe corrosion, or material entrainment. This connectionless and contactless feedback technology improves reliability by eliminating wear at the connection points. The harsh and demanding working conditions are a business opportunity for Fisher products. The Fisher DVC6200 electrical valve positioner is available for configuration. It can be installed as an integrated two-way valve and three-way valve on Fisher/GX, on Fisher angle stroke control valve actuators, on Fisher linear stroke control valve actuators, and on rotary and sliding rod actuators from other manufacturers; Compliant with IEC 60534-6-1, IEC 60534-6-2, VDI/VDE 3845, and NAMUR installation standards, Fisher DVC6200 electrical valve positioner input signal # Analog input signal: 4-20 mA DC standard split range control can also provide analog control # For Hart communication, the minimum voltage is 11VDC. # Reverse polarity protection: Reverse loop current will not cause instrument damage. Fisher DVC6200 electrical valve positioner output signal # is the pneumatic signal required by the actuator .....

Product Details

Product details introduction

Fisher FisherDVC6200positioningimplement

Fisher FisherDVC6200Series digital valvescontrollerAdded instruments with connectionless and contactless feedback technology;It is specifically designed for the presence of strong vibrationsApplication conditions with severe corrosion or material entrainment.This connectionless and contactless feedback technology improves reliability by eliminating wear at the connection points.The harsh and demanding working conditions areFisherBusiness opportunities for products

Fisher FisherDVC6200Electrical valvespositioningimplementAvailable for configuration

#Integrated installation inFisher / GXTwo way valve and three-way valve

#Installed onFisherAngular stroke control valveOn the executing agency

#Installed onFisherStraight stroke control valveOn the executing agency

#Installed on rotating and sliding rod actuators from other manufacturers; conform toIEC 60534-6-1,

IEC 60534-6-2, VDI/VDE 3845andNAMURInstallation standards

Fisher FisherDVC6200Electrical valvespositioningimplementInput signal

#Analog input signal:4-20 mADC standard split range control can also provide analog control

#answera surnameHartCommunication, the minimum voltage is11VDC.

#Reverse polarity protection: Reverse loop current will not cause instrument damage

Fisher FisherDVC6200Electrical valvespositioningimplementoutput signal

#For the pneumatic signal required by the executing agency, the maximum achievable gas source pressure95

Minimum range:0.4bar (6psi)Maximum range:9.5bar (140pis)

#Mode of action:Dual action,Single acting positive acting formula,And single action reaction type

#Is there position feedback included(4-20mAOutput)

Fisher FisherDVC6200valvepositioningimplementoperating ambient temperature

# -40to85

#-52to85℃ (option)

Fisher DVC6200valveDiagnostic level of locator

# HC Hart CommunicationHartCommunication)

# AD Advanced Diagnostics (Off-lineOffline Performance Diagnosis

# PD Performance Diagnostics (On-LineOnline performance diagnosis)

Fisher FisherDVC6200Electrical valvespositioningimplementValve stem travel

#Direct travel : Minimum11mm; Maximum606mm

#Rotation angle: minimum45linear measure; Maximum90linear measure

Fisher FisherDVC6200valvePositioner protection levelIP66

Ordering Information (Order Information Form)

1. Actuator type and size(Model of actuator)

1.1 actionSingle action positive action mode and single action negative action mode

1.2 Integrated installation on GX and GX 3-Way actuators

1.3 Installed on other angular and linear pneumatic actuators

Is there position feedback included(4-20mAOutput)

1.4 Mode of action:Double(Dual action)

2. Maximum actuator travel or rotation(Maximum stroke and angle of actuator)

3 . Diagnostic Tier Lever (Diagnostic level of locator)

3.1 HC Hart CommunicationHartCommunication)

3.2 AD Advanced DiagnosticsOff-lineOffline diagnosis)

3.3 PD Performance Diagnostics (On-Lineon-line diagnosis)

4. Hazardous Area Approval(Explosion proof rating)

4.1 Explosion proof grade: Exia IICT4/T5 intrinsic safety type/Exd IICT4/T5 explosion-proof type(optional