Welcome Customer !

Membership

Help

Jinhu Xinderui Automation Equipment Co., Ltd
Custom manufacturer

Main Products:

mechb2b>Products

Jinhu Xinderui Automation Equipment Co., Ltd

  • E-mail

    2316517588@qq.com

  • Phone

    19961810948

  • Address

    No. 99 Kejian Road, Dailou Industrial Concentration Zone, Jinhu County, Huai'an City

Contact Now

Fairchild Service Regulator Valve 64742K Filter

NegotiableUpdate on 01/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Fairchild service regulator valve 64742K filter 6474264742G, 64742GK $r $n Fairchild service regulator valve, 6474264742G, 64742GK, 64742K, Fairchild regulator valve, Fairchild filter, Fairchild 64742 pneumatic component, 64A type pressure regulator, range 1-60PSIG, 1/4IN FNPT port

Product Details

Fairchild Service Regulator Valve 64742K Filter64742,64742G,64742GK

The pressure regulator reduces the unregulated high input pressure to the regulated low output pressure. Its main function is to maintain regulated output pressure under both flowing and non flowing conditions.

Fairchild manufactures a complete set of precision pneumatic regulators, including positive pressure, back pressure, and vacuum models. Quality engineering and manufacturing ensure that our pressure regulators meet all the requirements of precision equipment.

We have a wide range of pressure and flow options, allowing you to choose models that meet your instrument or general industrial control application needs.

working principle

When you adjust the range screw to a specific set point, the range spring applies a downward force on the top to control the diaphragm. This downward force opens the supply valve. The output pressure flows through the outlet and the suction pipe to the control room when it is at the bottom of the control diaphragm. When the set point is reached, apply force to control the diaphragm to balance the output pressure acting on the bottom of the diaphragm, and close the supply valve. When the output pressure exceeds the set point, the diaphragm component moves upward to close the supply valve and open the exhaust valve. The output pressure flows through the exhaust valve and the vent on the side of the device until it reaches the set point. For more information, please refer to the cross-sectional diagram.

Specifications

traffic

22 feet per minute

Supply flow rate of 100 pounds per square inch (PSIG)

37.4 meters per hour

Extraction ability

1.0 feet per minute
2.54 meters per hour

sensitive

1.0 inch/toilet
2.54 centimeters

25 pounds per square inch variable pressure supply (PSIG)

%3C0.1 psig
%3C0.7 kPa

High pressure supply

300 psig
2100 kPa

scale

3 x 3 x 9 inches
76 x 76 x 229 millimeters

scope

0.5 to 30 pounds per square inch
1 to 60 pounds per square inch
3 to 200 kilopascals
10 to 400 kilopascals
2 to 120 pounds per square inch
15 to 800 kilopascals

Pipe thread size

1/4 inch