| Explosion proof air conditioning series:
Explosion proof air conditioning is a type of air conditioner that exists or may exist at a certain levelIIATheIIBGrade, temperature group isT1-T4Special equipment designed for places where combustible gases, steam, and air are mixed to form explosive gases and require temperature regulation, widely used in the petrochemical industry. Explosion proof air conditioning has been inspected and tested by the National Explosion proof Electrical Product Quality Supervision and Inspection Center(CQSTEx)Passed the inspection and obtained the explosion-proof certificate with the explosion-proof markExdmeibIIBT4.
This product has the characteristics of stable performance, beautiful appearance, safety and reliability, and easy operation, strictly following the following explosion-proof Standard design and manufacturing of electrical and dehumidification equipment:
GB3836.1-2000 Electrical equipment for explosive gas environments 第1Part: General Requirements
GB3836.2-2000 Electrical Equipment for Explosive Gas Environments2Part: Explosion proof type“d”
How to translate3GBB3836.3-200OElectrical Equipment for Explosive Gas EnvironmentsPart: Increased Safety Type
“e”4How to translateGBB3836.3-200O
Electrical Equipment for Explosive Gas Environments Part: Intrinsically Safe Type “i” How to translate
GB3836.9-1990 Explosion. Chen Environment Usedexplosion-proof1Sealed electrical equipment2“m” How to translateScope of Application◆Explosive gas environment:District or district◆Dangerous gases or vapors in the premises:IIATheIIBThe
IIC◆
There are temperature requirements(2.6Gas class T1-T5)Workshops, control rooms, analysis laboratories, hazardous materials warehouses, and offices, etc Other instructions:● The design parameters and data related to the above products are subject to the body nameplate and will not be notified separately● Applicable area and floor height:-3.0m
| ● There may be slight differences between the product image and the actual product, please refer to the actual product | ● For other details, please refer to the user manual of this product | ● Our company reserves the right to interpret the above promotional materials Main technical parameters | Specification model | Model Specification Model | Specification applicable area | Suitable Area Rated working voltage Rated Voltage | refrigeration capacity Cooling Capacity | refrigeration power Cooling Power | refrigeration current Coolong Current | refrigeration capacity Cooling Capacity heating | power Cooling Power heating | | current | Coolong Current | indoor unit dimensions | Outline | (Indoor) | Outdoor unit dimensions | Outline | (Outdoor) | m2 | VAC | | W W A | W | W | A | 2300 | 800 | 3.9 | 2600 | 830 | 4.1 | mm | mm | | wall-mounted | Hang | 2300 | 750 | 3.6 | Type | BKFR-23/LW2 | 10-16 | 220/230 | 795*160*290 | | 833*286*540 | BKF-23/LW2 | 2500 | 880 | 4 | 3000 | 950 | 4.5 | 10-16 | - | | - | - | 2500 | 820 | 3.8 | 795*160*290 | 833*286*540 | BKFR-25/LW2 | 12-18 | 795*265*182 | | 780*540*245 | BKF-25/LW2 | 2600 | 880 | 4.1 | 3100 | 1050 | 4.9 | 12-18 | - | | - | - | 2600 | 850 | 3.9 | 795*265*182 | 780*540*245 | BKFR-26/LW2 | 12-18 | 727*195*285 | | 730*260*535 | BKF-26/LW2 | 3300 | 1200 | 5.7 | 4000 | 1300 | 6.4 | 12-18 | - | | - | - | 3300 | 1160 | 5.5 | 727*195*285 | 730*260*535 | BKFR-33/LW2 | 15-21 | 880*160*295 | | 833*286*540 | BKF-33/LW2 | 3600 | 1280 | 6 | 4300 | 1380 | 6.5 | 15-21 | - | | - | - | 3600 | 1280 | 6 | 880*160*295 | 833*286*540 | BKFR-36/LW2 | 16-25 | 804*195*285 | | 855*331*596 | BKF-36/LW2 | 4000 | 1460 | 7.3 | 4600 | 1500 | 7.5 | 16-25 | - | | - | - | 4000 | 1400 | 7 | 804*195*285 | 855*331*596 | BKFR-40/LW2 | 17-27 | 938*200*271 | | 780*250*650 | BKF-40/LW2 | 5000 | 1880 | 8.8 | 6000 | 2170 | 10 | 17-27 | - | | - | - | 5000 | 1830 | 8.5 | 938*200*271 | 780*250*650 | BKFR-50/LW2 | 22-33 | 1100*205*330 | | 810*288*680 | BKF-50/LW2 | 7100 | 2500 | 11.8 | 8000 | 2650 | 12.7 | 22-33 | - | | - | - | 7100 | 2500 | 11.8 | 1100*205*330 | 810*288*680 | BKFR-71/LW2 | 32-49 | 1155*224*308 | | 948*340*830BKF-71/LW2 | 32-49 | - | 4800 | 1800 | 8.5 | - 1000 | - 1000 | 1155*224*308 | 948*340*830 | cabinet-type | | Cabinet Type | BKFR-48/GW1 | 4800 | 1800 | 8.5 | 21-32 | 6000+ | 2000+ | 9.1+4.7 | 500*250*1746 | | 810*288*680 | BKF-48/GW1 | 5100 | 1900 | 8.8 | 21-32 1000 | - 1000 | - | - | 500*250*1746 | | 810*288*680 | BKFR-51/GW1 | 5100 | 1900 | 8.8 | 23-34 | 6100+ | 1850+ | 8.6+4.7 | 500*290*1755 | | 810*288*680 | BKF-51/GW1 | 5800 | 2220 | 10.7 | 23-34 1000 | - 1000 | - | - | 500*290*1755 | | 810*288*680 | BKFR-58/GW1 | 5800 | 2220 | 10.4 | 26-40 | 6200+ | 2150+ | 10+4.7 | 500*250*1746 | | 810*288*680 | BKF-58/GW1 | 6100 | 2350 | 11.1 | 26-40 1000 | - 1000 | - | - | 500*250*1746 | | 810*288*680 | BKFR-61/GW1 | 6100 | 2350 | 11.1 | 28-42 | 6900+ | 2350+ | 11.1+4.7 | 500*290*1755 | | 860*308*730 | BKF-61/GW1 | 7100 | 2600 | 11.8 | 28-42 2000 | - 2000 | - | - | 500*290*1755 | | 860*308*730 | BKFR-71/GW1 | 7100 | 2600 | 11.8 | 32-49 | | 8500+ | 2700+ | 12.3+9.4 |
|