EOCRI3DM-WRDUHZ Schneider Intelligent Motor Protector

3DM2-H3DBW 3DM2-WRDBW+3CT-H3-300-C 3DM2-H4DUW 3DM2-WRDUW+3CT-H4-400-C 3DM2-H4DBW * Schneider Korean motor protector EOCR-i3DM, ◆ built-in MCU (microprocessor control unit) ◆ real-time monitoring/high precision
◆ Protection functions: overcurrent, undercurrent, reverse, phase loss, stall, current imbalance ◆ Additional functions: power failure protection, pre alarm, cumulative running time, and recording of three faults
EOCRI3DM-WRDUHZ Schneider Intelligent Motor Protector
◆ Built in MCU (microprocessor control unit)
Real time monitoring/high precision
◆ Protection functions: overcurrent, undercurrent, reverse, phase loss, stall, current imbalance
◆ Additional functions: power failure protection, pre alarm, accumulated running time, recording the cause and current of three faults and multiple reset modes to choose from
Schneider EOCR (formerly Sanhe, South Korea) EOCR-i3DM electronic motor protector
◆ Strengthen monitoring function: three-phase current cycle display&trip reason display
◆ Time limit/inverse time limit/overheat inverse time limit can be selected
The current amplitude bar can display the real-time operation status of the load
Communication method: Modbus RS-485
Schneider EOCR (formerly Sanhe, South Korea) EOCR-i3DM electronic motor protector
◆Built in MCU (microprocessor control unit)
◆ real-time monitoring/High precision
◆ Protection functions: overcurrent, undercurrent, reverse, phase loss, stall, current imbalance
◆ Additional functions: power failure protection, pre alarm, accumulated running time, recording the cause and current of three faults, and multiple reset modes to choose from
◆Enhanced monitoring function: three-phase current cycle display&trip reason display
◆Time limit/inverse time limit/overheat inverse time limit can be selected
◆The current amplitude bar can display the real-time operation status of the load
◆Communication method: Modbus RS-485
protection function
protection function |
Protection action time |
overcurrent |
0.2-30 seconds (timed limit), 1-30 classes (inverse time limit) |
Undercurrent |
OFF, Adjustable from 1 to 10 seconds |
phase loss |
OFF, Adjustable from 0.5 to 5 seconds |
locked-rotor |
Adjustable from 0.3 to 5 seconds |
stall |
D-Time |
Reverse phase (reversal) |
Within 0.15 seconds |
current imbalance |
Adjustable from 1 to 10 seconds |