-
E-mail
CONNORTEK@163.com
-
Phone
18049721441
-
Address
Room 901, No. 6, Lane 1011, Moyu South Road, Anting Town, Jiading District, Shanghai
Conner (Shanghai) Environmental Technology Co., Ltd
CONNORTEK@163.com
18049721441
Room 901, No. 6, Lane 1011, Moyu South Road, Anting Town, Jiading District, Shanghai
The 530 flow calibrator Defender530 is a new generation of dry gas flow meter, which is a primary flow meter and is used by numerous individual sampling pump manufacturers and accessories. Can be used in the fields of industrial hygiene, environmental protection, and various laboratories. It adopts the principle of dry piston motion, and multiple consecutive readings can be generated with one button press. Compared with the traditional foam flowmeter, it is more convenient and fast to use. The 520 and 530 models have added the ability to simultaneously test temperature and pressure compared to the 510.
Main Features
Adopting the principle of dry piston, it is simple and convenient to use
Accurate flow control, certified by ISO17025
compact structure
Large display screen
Up to 100 readings per group
Equipped with built-in temperature and pressure sensors to optimize test results (520 series)
Product Parameters
Specifications |
Defender 510 |
Defender 520 |
Defender 530 |
|
Model and flow range |
510L 5-500ml/min |
520L 5-500ml/min |
530L 5-500ml/min |
|
traffic accuracy |
1% |
1% |
1% |
|
Standard accuracy |
N/A |
N/A |
1.2% |
|
Optional measurement units |
traffic |
mL/min,L/min |
mL/min,L/min |
mL/min,L/min |
standardization |
N/A |
N/A |
smL/min,sL/min |
|
temperature |
N/A |
℃ or ℉· |
℃ or ℉ |
|
pressure |
N/A |
mmHg,PSI,kPa |
mmHg,PSI,kPa |
|
Temperature and pressure sensors |
No |
Yes |
Yes |
|
pressure |
N/A |
3.5 mmHg (typical) |
3.5 mmHg (typical) |
|
temperature |
N/A |
0.8 ℃ (typical) |
0.8 ℃ (typical) |
|
Time of each reading |
1-15 seconds |
|||
Reading mode (select the average of 1 to 100 measurements) |
Single (manual), continuous or burst mode |
|||
Gas compatibility |
Non corrosive gas, non condensing gas, humidity less than 70% |
|||
Flow mode |
Compression or suction |
|||
measurement unit |
integrated |
|||
AC/DC converter/charger |
12V DC,>250ma, 2.5mm center position |
|||
Battery Type |
6V rechargeable sealed lead-acid battery, working time 6-8 hours |
|||
Battery running time (5 times/minute) |
Backlight on for 3 hours, backlight off for 8 hours |
|||
Press in or suction attachments |
hose |
|||
warranty period |
1 year |
|||
Storage temperature |
0-70℃ |
|||
air humidity |
0-70% |
|||
Operating pressure () |
15 PSI |
|||
display |
Backlit graphic LCD display |
|||
Data port (using optimization software) |
RS-232 serial port |
|||
Data cable (using optimization software) |
1-meter Defender calibrator to computer serial port |
|||
protective case |
Paper instrument box |
|||
Size (HxD) |
140x150x75mm |
|||
weight |
820g |
|||