- Phone
-
Address
B108, No. 352 Outer Ring Road, Minhang District, Shanghai (201199)
Shanghai Yifeng Precision Instrument Co., Ltd
B108, No. 352 Outer Ring Road, Minhang District, Shanghai (201199)
| Measurement project | |
| Measurement project | Measurable roundness, coaxiality, concentricity, runout, perpendicularity, parallelism, flatness, surface waviness (Wc, Wp, Wv, Wt, Wa, Wq), frequency spectrum analysis, wave height analysis, etc. of circular workpieces |
| measuring range | |
| Maximum measurement diameter | φ1000mm |
| Maximum measurement height | 650mm |
| Capacity | 250Kg |
| Spindle Precision | |
| Radial error of spindle H=to the height of the workbench |
±(0.03+5H/10000)μm |
| Axial error of spindle X=distance to the center of the spindle |
±(0.03+6X/10000)μm |
| workbenches | |
| Table diameter | φ560mm |
| adjustment range | Adjust the eccentricity by ± 2mm; Adjust the level ± 1 ° |
| Rotation diameter | φ1000mm |
| rotational speed | 0-12 revolutions per minute |
| Horizontal arm (horizontal guide rail) | |
| Horizontal movement distance | 240mm |
| movement speed | 0.5-6mm/S or manual |
| sensor | |
| range | 500 μ m (radius difference) |
| resolution | 0.005μm |
| Measuring needle shape | 2mm gemstone ball measuring head (with more diameters to choose from) |
| dynamometry | 1-12g |
| data acquisition | |
| data acquisition | 14400 points per week (internationally recognized) |
| Magnification factor | |
| Magnification factor | 200000 times automatic |
| appraising method | |
| appraising method | LSC (Least Squares Method), MZC (Minimum Region Method) MIC (maximum inscribed circle method), MCC (minimum circumscribed circle method) |
| Filter value | |
| Filter value | 1-500、1-150、1-50、1-15、3-16、3-17、15-500、17-100 upr |
| Data analysis and processing | |
| Spectrum analysis | Analyze the amplitude of different frequency components |
| Abnormal data removal | Manually or automatically remove abnormal data such as burrs, holes, and bumps |
| file management | Measurement data is automatically saved and can be deleted |
| Data printing | Single or multiple measurement results can be printed on the same page in the same printing mode |
| INSTALLATION REQUIREMENTS | |
| power supply | 220-240V AC, 50HZ, Separate ground wire; Maximum power consumption 450W |
| compressed air | Pure compressed air: pressure 0.4MP, consumption 0.1m3/min (air supply 0.6MP, 0.25m3/min or above) |
| Environmental requirements | Working temperature: 10 ° -30 ° C (normal temperature); Humidity 20-80% RH (no condensation), good grounding, no obvious vibration source |