lDC7-30VWide voltage power supply;
lRS485Communication isolation;
lRS232Communication;
lCommunication interface supportRS232、RS485;
lstandardmodbusProtocol, while also supportingRTU、TCP、ASCIIformat;
lCan be set0-255Device address, set through software.
l12roadPT100Temperature acquisition channel,24positionADtransformation;
lTemperature acquisition resolution0.01℃;
lTemperature acquisition accuracy±0.1℃;
l12road12Bit resolution analog quantity4-20maperhaps0-10vinput;
lAccuracy of analog quantity acquisition±0.01ma/v;
lSupporting baud rate:2400,4800,9600,19200,38400(Can be modified through software, default)9600).
PT100In the three wire system, as shown in the figure,AgiveB、AgiveCThe resistance value between them is at room temperature110Around Ohm,BgiveCBetween them is0Oh. Oh.
The serial port that comes with a computer is usuallyRS232It needs to be equipped232-485Converter (recommended for industrial environments to use active band isolated converters), after conversionRS485doA、BTwo lines,AConnect to the boardATerminal,BConnect to the boardBTerminal,485Shielding can be connectedPBIf there are many devices, it is recommended to use twisted pair shielded wires and adopt a chain network structure.
Collected by devicesThe relationship between AI data and actual input values:
actualprice=returnprice*0.001(ma/v)
Software download link address:http://www.juyingele.com.cn/software/software/JYDAMdebugging software.rar

For detailed usage instructions, please refer to:JYDAMDebugging software user manual
ØAddress of dip switch
uAll five dialing codes have been dialedWhen in the "ON" position, it is the address "31”;
uAll five dialing codes have been dialedWhen in the "OFF" position, it is the address“1”;
ufar left1 is the lowest binary bit.
uAddress Table:
ØOffset Address
The default offset address is0. Set up through software:

ØPower on the device again;
Use the modified baud rate for communication testing.
Compensation software download address:http://www.juyingele.com.cn/software/software/Temperature compensation software.rar
PT100Sensors are resistance signals, and the line loss values of sensors of different lengths vary. Line loss compensation needs to be carried out according to the different lengths of sensor cables;
Corresponding relationship between line loss value and temperature: 380milliohms= 1℃;
For example:
① TheThe current collected temperature value is29.91℃, the actual temperature value is28.91℃. The temperature value that needs to be compensated is-1℃,
The compensation value written380/10=38The specific compensation interface screenshot is shown in the following figure:
② TheThe current collected temperature value is30.05℃, the actual temperature value is33.05℃. The temperature value that needs to be compensated is3℃, the compensation value written is-3×(380/10)=-114The specific compensation interface screenshot is shown in the following figure:
This product supports standardsmodbusInstructions, for detailed instruction generation and parsing methods, please refer to the register table in this article for reference《MODBUSThe Chinese version of the agreement is sufficient.
ModbusChinese reference for the agreement:
http://www.juyingele.com.cn/software/software/Modbus%20POLLSoftware and User Manual.rar
Coil register address table:
Table of Baud Rate Values
Attention: Use a third-party host computer, such as KingviewMCGS、PLCWhen waiting for the software,PLCRegister addresses will be offset1.
useJYDAMDebugging software can generate query channel instructions
The relationship between the obtained temperature data and the actual input value is: actual value=return value*0.1
Query the temperature of the first channel
FE040000000125C5
Simulated return information:
FE 04 0209 92 2A D9
query12temperature
FE040000000CE400
Simulated return information:
FE 041800 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0081 60
The relationship between the obtained analog data and the actual input value is: actual value=return value*0.001
Query analog quantityAD character
Send code:FE 04 001400 0C A4 04
Simulated return information:
Return code:FE04 1800 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 81 60
1、Use the relay board after power supply232The interface cannot establish communication and cannot be controlled
Firstly, test whether different baud rates can be controlled,485Interface AttentionA+、B-Shielded wires are not necessary, but they must be connected in situations with high communication error rates, even if the distance is very close.
2、485Bus, mounted greater than1I have a device with a broadcast address255transmiting relay1Absorb, but not all modules' relays1Suck and.
The broadcast address can be used when there is only one device on the bus, greater than1Please use dip switches to distinguish addresses when controlling individual devices, otherwise instructions may not be executed correctly due to asynchronous judgment of communication data by the module.
3、SiemensPLCUnable to communicate properly with the device
Siemens485busABDefinition opposite to equipment.