E-mail
wxsunan003@163.com
-
Phone
13915351320
-
Address
No. 48, Huguang Road, Fenshui, Yixing, Wuxi City
Wuxi Sunan Experimental Equipment Co., Ltd
wxsunan003@163.com
13915351320
No. 48, Huguang Road, Fenshui, Yixing, Wuxi City
Composite salt spray test chamberIt is a surface treatment for various materials, including coating, electroplating, anodizing, spraying, anti rust oil and other anti-corrosion treatments, to test the corrosion resistance of their products.
Performance Characteristics
1. Having independent intellectual property rights and appearance design, as well as mastering the core technology of environmental testing chambers
2. The control instrument adopts Japanese * and can be remotely monitored
control instrument
3. The refrigeration system adopts the original French Taikang compressor unit and is equipped with a condensate drain pan
4. The core electrical components are all imported brands such as Schneider
5. Following the design concept of foreign environmental testing equipment, separating water and electricity
6. Shallow slot humidification, innovative *, drawer style water filling method, large water tank design
7. The bottom of the studio adopts a drainage groove design to prevent steam condensation and maximize the protection of the test workpiece
8. The lighting system adopts Philips kit, and the observation window adopts a funnel-shaped design, providing a wider observation field of view
9. The leakage protection design of * ensures safer operation
10. Strive for excellence and focus on every detail
Test Principle
The corrosive solution is sprayed into mist by compressed air, which surrounds the test sample in the testing chamber.
Testing can be continuous or cyclic.
The corrosion resistance of each sample is defined as the time during which corrosion occurs, and the longer the time, the better the corrosion resistance.
Composite salt spray test chamberTechnical Indicators:
1. Temperature range: -60 ℃~150 ℃
2. Humidity range: 30-98% RH (at temperatures between 25 ℃ and 80 ℃)
3. Temperature uniformity: ≤ 2 ℃ (when unloaded)
4. Humidity uniformity:+2, -3% RH
5. Temperature fluctuation: ± 0.5 ℃ (when unloaded)
6. Humidity fluctuation: ± 2%
7. Temperature deviation: ± 2 ℃
8. Humidity deviation: ± 2%
9. Cooling rate: 0.7-1.0 ℃/min
10. Heating rate: 1.0-3.0 ℃/min
11. Time setting range: 1 to 9999H
12. Humidity fluctuation range: 40-98% RH